Simons Voss Digital Cylinder AX User manual

Digital Cylinder AX
(Z5)
Manual
11.01.2022

Contents
1 Intended use ................................................................................................................................................ 5
2 General safety instructions.....................................................................................................................6
3 Product-specific safety instructions....................................................................................................9
4 AP-specific safety instructions..............................................................................................................11
5 Structure ......................................................................................................................................................12
5.1 Mechanical thumb-turn...............................................................................................................................13
5.2 Electronic thumb-turn..................................................................................................................................13
5.3 Comfort cylinder (CO; reader on one side)....................................................................................... 14
5.4 Freely-rotating cylinder (FD; reader on both sides)...................................................................... 14
5.5 Half cylinder (HZ, reader on one side)................................................................................................. 15
5.5.1 Scandinavian Oval (SO)............................................................................................................15
5.5.2 Scandinavian Round – (RS)....................................................................................................16
6 Basic configuration, profiles and features ........................................................................................17
6.1 Basic configuration.........................................................................................................................................17
6.1.1 Comfort cylinder (CO; reader on one side) ...................................................................... 17
6.1.2 Freely-rotating cylinder (FD; reader on both sides) .....................................................18
6.1.3 Half cylinder (HZ, reader on one side)................................................................................18
6.2 Profiles................................................................................................................................................................. 18
6.2.1 Standard Euro profile cylinder as per to DIN 18525 / EN1303.................................18
6.2.2 Swiss round (SR) ..........................................................................................................................19
6.2.3 Scandinavian oval (SO).............................................................................................................19
6.2.4 Scandinavian Round – (RS)....................................................................................................19
6.3 Versions ............................................................................................................................................................. 20
6.3.1 Anti-panic (AP) ............................................................................................................................ 20
6.3.2 Access Control (ZK) .................................................................................................................... 21
6.3.3 Brass version (MS) ...................................................................................................................... 22
6.3.4 Waterproof version (WP) ........................................................................................................ 22
6.3.5 Integrated network node (LN)............................................................................................... 22
6.3.6 Multi-point (MR)...........................................................................................................................23
6.3.7 VdS version Class BZ (VDS)...................................................................................................23
7 Accessories ................................................................................................................................................25
7.1 Special tools.....................................................................................................................................................25
7.2 Components.................................................................................................................................................... 26
7.2.1 LockNode .........................................................................................................................................26
7.2.2 Replacement caps ......................................................................................................................26
7.2.3 Length modularity........................................................................................................................28
7.2.4 Core extension...............................................................................................................................28
Digital Cylinder AX (Z5) (Manual) Contents
2 / 158

7.2.5 Thumb-turns ..................................................................................................................................29
8 Programming..............................................................................................................................................31
9 Installation .................................................................................................................................................33
9.1 Brief descriptions (entire assembly) ....................................................................................................33
9.1.1 Comfort cylinder/anti-panic cylinder (CO/AP, reader on one side)...................33
9.1.2 Freely-rotating cylinder (FD; reader on both sides) ....................................................34
9.1.3 Half cylinder (HZ, reader on one side)...............................................................................35
9.1.4 Scandinavian oval/round (SO/RS).................................................................................... 36
9.2 Detailed descriptions (individual steps).............................................................................................37
9.2.1 Mounting thumb-turn (mech.) .............................................................................................. 37
9.2.2 Unmounting the thumb-turn (mech.) .............................................................................. 38
9.2.3 Mounting thumb-turn (electr.)............................................................................................. 40
9.2.4 Unmounting the thumb-turn (electr.) ...............................................................................43
9.2.5 Functional test...............................................................................................................................47
9.2.6 AP functional test ........................................................................................................................47
9.2.7 Insert locking cylinder................................................................................................................ 49
9.2.8 Fixing the locking cylinder........................................................................................................ 50
10 Customise Cylinder AX............................................................................................................................51
10.1 LockNode........................................................................................................................................................... 51
10.1.1 Remove cap.....................................................................................................................................51
10.1.2 Installation.......................................................................................................................................53
10.1.3 Attach the cap ...............................................................................................................................55
10.2 Replacement caps ....................................................................................................................................... 56
10.2.1 Remove cap.................................................................................................................................... 57
10.2.2 Attach the cap .............................................................................................................................. 59
10.3 Length modularity ........................................................................................................................................60
10.3.1 Extend Cylinder AX .....................................................................................................................60
10.3.2 Shorten Cylinder AX.................................................................................................................... 73
10.3.3 Combine CO cylinders to FD.................................................................................................. 85
10.3.4 Reduce CO cylinders to HZ .................................................................................................. 100
10.4 Core extension................................................................................................................................................113
10.4.1 Scope of delivery .........................................................................................................................114
10.4.2 Installation...................................................................................................................................... 114
10.5 Escape knob ...................................................................................................................................................125
10.5.1 Installation on fitted cylinder (clockwise unlocking)................................................ 125
10.5.2 Installation on the removed cylinder (anticlockwise unlocking)........................ 129
11 Signalling ..................................................................................................................................................143
12 Maintenance............................................................................................................................................144
12.1 Battery replacement ................................................................................................................................. 144
Digital Cylinder AX (Z5) (Manual) Contents
3 / 158

12.2 Cleaning and disinfection........................................................................................................................ 149
13 Technical specifications ......................................................................................................................150
13.1 Euro Profile and SwissRound................................................................................................................ 150
13.2 Scandinavian Oval Scandinavian Round..........................................................................................151
13.3 Dimensions......................................................................................................................................................153
14 EU/UK Declaration of conformity.....................................................................................................156
15 Help and other information ................................................................................................................ 157
Digital Cylinder AX (Z5) (Manual) Contents
4 / 158

1 Intended use
You can install AX digital locking cylinders (Z5) in door locks designed for
this purpose (e.g. DIN mortise locks) and integrate them into a digital
locking system.
The AX digital locking cylinder is available in various lengths and versions.
Make sure that your AX locking cylinder has the correct length. You can
measure the length of your AX locking cylinder at any time and adjust it
yourself.
If the AX locking cylinder is too short, you cannot mount the thumb-
turns.
If the AX locking cylinder is too long, the AX locking cylinder can be torn
out of the lock.
Do not modify the AX locking cylinder (except to carry out modifications
described in this manual).
Digital Cylinder AX (Z5) (Manual) 1. Intended use
5 / 158

2 General safety instructions
Signal word (ANSI
Z535.6) Possible immediate effects of non-compliance
DANGER Death or serious injury (likely)
WARNING Death or serious injury (possible, but unlikely)
CAUTION Minor injury
IMPORTANT Property damage or malfunction
NOTE Low or none
WARNING
Blocked access
Access through a door may stay blocked due to incorrectly fitted and/or in-
correctly programmed components. SimonsVoss Technologies GmbH is
not liable for the consequences of blocked access such as access to in-
jured or endangered persons, material damage or other damage!
Blocked access through manipulation of the product
If you change the product on your own, malfunctions can occur and access through a door can
be blocked.
Modify the product only when needed and only in the manner described in the
documentation.
Do not swallow battery. Danger of burns from hazardous substances
This product contains lithium button cell batteries. Swallowing the button cell battery, in can
result in severe internal burns leading to death in as little as two hours.
1. Keep new and used batteries away from children.
2. If the battery compartment does not close securely, cease using the product and keep it
away from children.
3. If you think batteries have been swallowed or are in any part of the body, seek medical
attention immediately.
Risk of explosion due to incorrect battery type
Inserting the wrong type of battery can cause an explosion.
Only use the batteries specified in the technical data.
Digital Cylinder AX (Z5) (Manual) 2. General safety instructions
6 / 158

CAUTION
Fire hazard posed by batteries
The batteries used may pose a fire or burn hazard if handled incorrectly.
1. Do not try to charge, open, heat or burn the batteries.
2. Do not short-circuit the batteries.
IMPORTANT
Damage resulting from electrostatic discharge (ESD)
This product contains electronic components that may be damaged by electrostatic discharges.
1. Use ESD-compliant working materials (e.g. Grounding strap).
2. Ground yourself before carrying out any work that could bring you into contact with the
electronics. For this purpose, touch earthed metallic surfaces (e.g. door frames, water pipes
or heating valves).
Damage resulting from liquids
This product contains electronic components that may be damaged by liquids of any kind.
Keep liquids away from the electronics.
Damage resulting from aggressive cleaning agents
The surface of this product may be damaged as a result of the use of unsuitable cleaning agents.
Only use cleaning agents that are suitable for plastic or metal surfaces.
Damage as a result of mechanical impact
This product contains electronic components that may be damaged by mechanical impacts of
any kind.
1. Avoid touching the electronics.
2. Avoid other mechanical influences on the electronics.
Damage due to polarity reversal
This product contains electronic components that may be damaged by reverse polarity of the
power source.
Do not reverse the polarity of the voltage source (batteries or mains adapters).
Operational malfunction due to radio interference
This product may be affected by electromagnetic or magnetic interference.
Do not mount or place the product directly next to devices that could cause electromagnetic
or magnetic interference (switching power supplies!).
Digital Cylinder AX (Z5) (Manual) 2. General safety instructions
7 / 158

Communication interference due to metallic surfaces
This product communicates wirelessly. Metallic surfaces can greatly reduce the range of the
product.
Do not mount or place the product on or near metallic surfaces.
NOTE
Intended use
SimonsVoss-products are designed exclusively for opening and closing
doors and similar objects.
Do not use SimonsVoss products for any other purposes.
Malfunctions due to poor contact or different discharge
Contact surfaces that are too small/contaminated or different discharged batteries can lead to
malfunctions.
1. Only use batteries that are approved by SimonsVoss.
2. Do not touch the contacts of the new batteries with your hands.
3. Use clean and grease-free gloves.
4. Always replace all batteries at the same time.
Different times for G2 locks
The internal time unit of the G2 locks has a technical tolerance of up to ± 15 minutes per year.
Qualifications required
The installation and commissioning requires specialized knowledge.
Only trained personnel may install and commission the product.
Incorrect installation
SimonsVoss Technologies GmbH accepts no liability for damage caused to doors or compon-
ents due to incorrect fitting or installation.
Modifications or further technical developments cannot be excluded and may be implemented
without notice.
The German language version is the original instruction manual. Other languages (drafting in the
contract language) are translations of the original instructions.
Read and follow all installation, installation, and commissioning instructions. Pass these instruc-
tions and any maintenance instructions to the user.
Digital Cylinder AX (Z5) (Manual) 2. General safety instructions
8 / 158

3 Product-specific safety instructions
WARNING
Blocking of escape routes due to faulty function
If mortise locks with panic function are to be used together with a locking
cylinder, improper use of locking cylinders may result in the panic function
not functioning properly.
1. Make sure that all parts of the closure are in working condition (EN 179).
2. Only install the cylinder in mortise locks for which it has been expressly
approved (refer to the documentation of the lock manufacturer).
Locking in people as a result of closures or sealing strips on the door unit
If locks or sealing strips are attached to the door unit, the locking cylinder may not function prop-
erly.
Make sure that any locks or sealing strips do not interfere with the operation of the locking
cylinder.
IMPORTANT
Assembly error due to incorrect length
The AX locking cylinder is available in various lengths. If you order the wrong length, the AX lock-
ing cylinder cannot be installed correctly.
Order your AX locking cylinder in the correct length or adjust the length yourself.
Mechanical damage to the thumb turn as a result of obstacles
If the thumb turn can knock against the wall or other objects as a result of the installation situ-
ation, it may become damaged.
In such situations, use a suitable door stop.
Damage caused by moisture in outdoor use
Moisture can damage the electronics.
1. If you want to use the locking cylinder for outdoor applications or in high humidity (bathrooms
or washrooms), use the WP version.
2. Carefully insert the locking cylinder to avoid damaging the O-rings.
Damage to the AX locking cylinder due to unsuitable tools
Special tools are required to open the cover and dismantle the AX locking cylinder. If you use un-
suitable tools, you may damage the AX locking cylinder.
Only use the separately available SimonsVoss special tool (
Accessories [}25]
).
Digital Cylinder AX (Z5) (Manual) 3. Product-specific safety instructions
9 / 158

NOTE
Locking up of persons without means of identification
The freely-rotating construction of the closing cylinder can only be opened
with a means of identification from both sides.
Ensure that no persons without means of identification are in the
secured area.
Freely rotating active/hybrid Digital Cylinder AX only with shortened range
With freely rotating cylinders, the reader knobs may not have sufficient clearance at low cylinder
lengths. Due to the range of the active technology, the radio signal can also be unintentionally re-
ceived by the second reader knob.
1. Program freely rotating cylinders with the SmartStick AX or the SmartCD.MP.
2. Ensure that the short range is selected during programming (standard setting for cylinders
factory- supplied as freely rotating).
Door obstructed by locking cylinder
Make sure that the opening and closing of the door is not obstructed by the locking cylinder or
parts thereof.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad excludes authorisation security class D ac-
cording to DIN EN 15684:2021.
VdS conditions
VdS approval for class BZ is subject to the following conditions:
1. Protect your VdS/SKG Digital Cylinder AX with burglar-resistant door plates B or C certified
according to VdS/SKG (DIN 18257 class ES 2 or ES 3).
2. Make sure that the Digital Cylinder AX does not protrude more than 3 mm.
3. Do not use your Digital Cylinder AX with MIFARE Classic, PinCode keypad, BLE or WaveNet.
Fire resistance
The fire resistance of the Digital Cylinder AX tested according to DIN EN 1634-2: 2009:05 for fire
and smoke resistant doors (type: wood and wood-product fire protection doors with a resistance
time of 90 minutes). The test report has the PfB number 18/11-A495-B1 (test institute for con-
struction elements).
Digital Cylinder AX (Z5) (Manual) 3. Product-specific safety instructions
10 / 158

4 AP-specific safety instructions
For locking cylinders with anti-panic function, also observe the following
safety instructions:
WARNING
Failure of the escape door function
The use of unsuitable components or components that are not ready for
operation can impair the function of an escape door. If you use the anti-
panic cylinder in non-approved locks, the escape door function may be im-
paired and cannot be released again.
1. Make sure that all parts of the lock are ready for operation.
2. Make sure that the panic function of the mortise lock is ensured.
3. Please refer to the documentation of the lock manufacturer.
4. Only use the anti-panic cylinder within the specified temperatures.
5. Perform a function test after installation or battery change of the anti-
panic cylinder.
Malfunction of the anti-panic function due to unauthorised manipulation
The length of the Cylinder AX can be modified. If the AP side is removed, the anti-panic unit may
be damaged.
Do not change the length on the AP side.
CAUTION
Hand injuries from carrier springing back
A spring-loaded carrier is used in the anti-panic construction of the closing
cylinder. This carrier can spring back when it is not installed, causing hand
injuries.
Do not hold the anti-panic construction of the closing cylinders in the
area of the carrier.
NOTE
Maintenance interval of not more than one month for emergency exit
locks
As per European standard EN 179, Appendix C, all components in a locking
device must be checked at intervals no greater than one month to ensure
that they are in satisfactory working order as part of emergency exit locking
device maintenance.
Digital Cylinder AX (Z5) (Manual) 4. AP-specific safety instructions
11 / 158

5 Structure
The Digital Cylinder AX has a modular construction. It always consists of a
cylinder profile with drill protection and actuator integrated in the core with
an external thumb-turn and optionally an internal thumb-turn.
The knobs are removable. However, the thumb-turn mounts of the
electronic and mechanical thumb-turns are not compatible with each
other. Electronic thumb-turns only fit on a mounting for electronic thumb-
turns and mechanical thumb-turns fit on a mounting for mechanical
thumb-turns.
You can now also use the Digital Cylinder AX with Euro profile (see
Standard Euro profile cylinder as per to DIN 18525 / EN1303 [}18]
) to suit
your individual needs (see
Length modularity [}60]
):
Recombine cylinders and replace thumb-turn mounts.
Extend or shorten the cylinder profile for Euro profile cylinders.
The Digital Cylinder AX is supplied with batteries, which are located in the
electronic thumb-turn.
Digital Cylinder AX (Z5) (Manual) 5. Structure
12 / 158

5.1 Mechanical thumb-turn
The mechanical knob is a single component. It consists of the knob housing
with embossed logo and two magnetic pins for assembly and disassembly.
5.2 Electronic thumb-turn
The electronic thumb-turn is composed of several components. Externally,
it differs from the mechanical thumb-turn by:
a door-side transparent cover for signalling
a removable lid with printed logo
The lid is available in different designs and can be replaced (see
Components [}26]
).
The electronic thumb-turn also contains:
Mount for a network node (LNI)
Holder for two batteries (CR2450) with reclosable flap
Two replaceable CR2450 batteries (see
Battery replacement [}144]
and
Technical specifications [}150]
)
Digital Cylinder AX (Z5) (Manual) 5. Structure
13 / 158

5.3 Comfort cylinder (CO; reader on one side)
The comfort cylinder consists of:
a mechanical thumb-turn
an electronic thumb-turn
a cylinder profile
5.4 Freely-rotating cylinder (FD; reader on both sides)
The freely-rotating cylinder consists of:
two electronic thumb-turns
a cylinder profile
Digital Cylinder AX (Z5) (Manual) 5. Structure
14 / 158

5.5 Half cylinder (HZ, reader on one side)
The half cylinder consists of:
an electronic thumb-turn
a cylinder profile
5.5.1 Scandinavian Oval (SO)
The Digital Cylinder AX for SO mortise locks is structured similarly to a half
cylinder and consists of:
an electronic thumb-turn
a cylinder profile with tappet
The Digital Cylinder AX for SO mortise locks can be used in different ways:
With a second Digital Cylinder AX for SO mortise locks (as freely
rotating cylinder)
With a mechanical cylinder for SO mortise locks (as comfort cylinder)
Without other cylinders (as half cylinders)
Digital Cylinder AX (Z5) (Manual) 5. Structure
15 / 158

5.5.2 Scandinavian Round – (RS)
The Digital Cylinder AX for RS mortise locks is structured similarly to a half
cylinder and consists of:
an electronic thumb-turn
a cylinder profile with tappet
The Digital Cylinder AX for RS mortise locks can be used in different ways:
With a second Digital Cylinder AX for RS mortise locks (as freely
rotating cylinder)
With a mechanical cylinder for RS mortise locks (as comfort cylinder)
Without other cylinders (as half cylinders)
Digital Cylinder AX (Z5) (Manual) 5. Structure
16 / 158

6 Basic configuration, profiles and features
The Digital Cylinder AX is available in different versions:
Basic configuration [}17]
Comfort cylinder (freely-
rotating, one-sided mech-
anical) [}17]
CO
Freely rotating (freely ro-
tating on both sides)
[}18]
FD
Half cylinder (freely rotat-
ing on one side) [}18]
HZ
Profiles [}18]
Standard (Euro profile cyl-
inder as per DIN 18525 /
EN1303) [}18]
EU
Swiss Round [}19]
SR
Scandinavian Oval [}19]
SO
Round Scandinavian
[}19]
RS
Versions [}20]
Anti-panic function AP
Access control [}21]
ZK
Brass version [}22]
MS
Waterproof design [}22]
(For protection class, see
Technical specifications
[}150]
)
WP
Integrated network node
[}22]
LN
Multi-point [}23]
MR
You can combine the variants described in the table to create Digital
Cylinder AX for you. Please refer to the currently valid product catalogue for
details on combination and availability. The options are described in more
detail in the following chapters.
6.1 Basic configuration
6.1.1 Comfort cylinder (CO; reader on one side)
In this version, a thumb-turn is mechanically connected to the locking cam.
You can open and close the door from this side without an identification
medium.
Digital Cylinder AX (Z5) (Manual)
6. Basic configuration, profiles and fea-
tures
17 / 158

6.1.2 Freely-rotating cylinder (FD; reader on both sides)
Both knobs are freely rotating in this design. You must have an
identification medium to engage this locking cylinder.
NOTE
Freely rotating active/hybrid Digital Cylinder AX only with shortened
range
With freely rotating cylinders, the reader knobs may not have sufficient
clearance at low cylinder lengths. Due to the range of the active techno-
logy, the radio signal can also be unintentionally received by the second
reader knob.
1. Program freely rotating cylinders with the SmartStick AX or the
SmartCD.MP.
2. Ensure that the short range is selected during programming (standard
setting for cylinders factory- supplied as freely rotating).
6.1.3 Half cylinder (HZ, reader on one side)
In this version, there is only an actuator or thumb-turn mount on one side of
the lock bit.
6.1.3.1 Scandinavian Oval (SO)
6.1.3.2 Scandinavian Round – (RS)
6.2 Profiles
6.2.1 Standard Euro profile cylinder as per to DIN 18525 / EN1303
In this version, the Digital Cylinder AX is supplied with a cylinder profile for
Euro profile cylinders.
Digital Cylinder AX (Z5) (Manual)
6. Basic configuration, profiles and fea-
tures
18 / 158

6.2.2 Swiss round (SR)
In this version, the Digital Cylinder AX is supplied with a cylinder profile for
Swiss Round.
6.2.3 Scandinavian oval (SO)
In this version, the Digital Cylinder AX is supplied with a cylinder profile for
Scandinavian Oval.
6.2.4 Scandinavian Round – (RS)
In this version, the Digital Cylinder AX supplied with a cylinder profile for
Scandinavian Round.
Digital Cylinder AX (Z5) (Manual)
6. Basic configuration, profiles and fea-
tures
19 / 158

6.3 Versions
6.3.1 Anti-panic (AP)
Doors can be fitted with mortise locks with panic function. In some mortise
locks, the panic function can be blocked by certain positions of the tappet
(area R).
345°
O section: 15° to 345°
15°
(15)°(15)°
150°
210°
(30)°
(30)°
R section:
15° to 150°
R section:
210° to 345°
U section: 150° to 210°
For these doors/mortise locks a Digital Cylinder AX with panic function
(AP) must be used.
Digital Cylinder AX with panic function are equipped with a spring
mechanism which always pulls the tappet into a non-critical position (area
O or area U). This means that the tappet can no longer block the panic
function of a panic lock.
Installation does not differ from installation of the normal comfort cylinder
(see
Comfort cylinder/anti-panic cylinder (CO/AP, reader on one side)
[}33]
).
For doors built along escape routes after April 2003, the following points
must be observed:
All closures for which the approvals state that the Digital Cylinder AX
does no affect the function of the lock, all Digital Cylinder AX can be
used.
Digital Cylinder AX (Z5) (Manual)
6. Basic configuration, profiles and fea-
tures
20 / 158
This manual suits for next models
1
Table of contents
Other Simons Voss Lock manuals
Popular Lock manuals by other brands

Kaba Mauer
Kaba Mauer Varios E 70171 Mounting instructions

IKEA
IKEA ROTHULT manual

Sudhaus
Sudhaus Combi-Code 1157 Instructions for using

Alarm Lock
Alarm Lock Trilogy DL1200 Mounting and installation instructions

Digilock
Digilock numeris aspire installation guide

Kaba
Kaba Simplex 1000 Series installation instructions

Kaba Mauer
Kaba Mauer 82021 Code-Combi K Operational instructions

Alarm Lock
Alarm Lock TRILOGY DL2700 installation instructions

Olympus Lock
Olympus Lock 200DW installation instructions

Taymor
Taymor CONCIERGE 100 user guide

Assa Abloy
Assa Abloy Corbin Russwin BLSS ML2000 Series installation instructions

radefy
radefy Bluetooth Smart Lock installation manual