manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Simplex
  6. •
  7. Security Sensor
  8. •
  9. Simplex 4098-9839 User manual

Simplex 4098-9839 User manual

4098-9839 Smoke Detector Data Reader
Quick Reference Guide
574-498
Rev. A
1998 Simplex Time Recorder Co. Gardner, MA 01441-0001 USA
1998 Simplex International Time Equipment Co., Ltd. Mississaugua, Ontario L4V 1H3 Canada.
All specifications and other information shown were current as of publication, and are subject to change without notice.
350E4C3D4OF8E1OE
1B 20%ALM #001
Red
LED Green
LED MODE
● ❍ Reader is in scan mode.
❍ ● Valid reading with a NORMAL condition.
● ● Valid reading with a TROUBLE condition.
●indicates illuminated LED ❍indicates LEDs that are OFF
NOTES:
1. DO NOT depress all push buttons on
the data reader simultaneously, this
can clear the memory.
2. The detector must be cleaned or
replaced if the display indicates a
greater than “50%ALM” reading.
3. Replace battery when
“∗∗∗ LOW BAT ∗∗∗” is displayed.
4. Compatible Smoke Detectors:
4098-9601, -9602, -9605.
5. For future use, not applicable with
basic operation.
Figure 1. 4098-9839 Data Reader
OPERATING INSTRUCTIONS:
To operate the data reader, follow Steps 1 through 6.
1. Turn the ON/OFF switch of the reader to the ON position. The Red LED on
the reader illuminates.
2. Point the focusing lens of the reader directly at a compatible smoke detector’s
LED, no more than 12 inches away. (See Note 4.)
3. When a valid reading is made, the Green LED on the reader illuminates.
4. After a valid reading is taken there are two possible conditions. If the
condition is NORMAL the Green LED is lit alone. If there is a TROUBLE
condition, both the Green and Red LEDs of the reader are illuminated.
(Refer to Figure 1.)
5. When both LEDs are illuminated or if greater than “50%ALM” is indicated,
clean or replace the detector. Refer to Application Manual 574-709 for
detector cleaning.
6. Press the SCAN button on the reader to go to the next detector.
Note: The STORE button is not applicable with basic operation. If accidentally
pressed, take the following steps to clear the reader’s memory.
1. Power the reader OFF.
2. Hold down the STORE and D/L buttons simultaneously.
3. Power the reader ON with the STORE and D/L buttons pressed for five
seconds.
4. Release the buttons.
Figure 2. Reader Display Information
Focusing Lens:
Aim at a target
(maximum of 12
inches away)
Serial Data Port:
See Note 5
Green LED
Store Button:
See Note 5
D/L (Download) Button:
See Note 5
LCD Display
(Diagnostic data,
See Note 5
)
See Note 2
Red LED
ON/OFF Switch:
Powers the reader
ON or OFF
Scan Button:
Press button to put
reader into a scan
mode (indicated by an
illuminated Red LED)
9V Battery Housing:
Located on the back of
the reader
See Note 5
See Note 5
firealarmresources.com
574-498
Rev. A
Device
Number Device Location Test One Test Two Test Three
See Example Below DATE % to
ALM TBL
Y/N DATE % to
ALM TBL
Y/N DATE % to
ALM TBL
Y/N
ZN1 - 27 East Corridor, Room 15 1/4/98 20% Y / N 1/4/99 20% Y / N 1/4/00 30% Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Y / N Y / N Y / N
Zone: ______________________
Tested By: __________________
Photocopy chart as necessary
firealarmresources.com

Other Simplex Security Sensor manuals

Simplex 4098 User manual

Simplex

Simplex 4098 User manual

Simplex 4098-9687 User manual

Simplex

Simplex 4098-9687 User manual

Simplex 2098-9201 Configuration guide

Simplex

Simplex 2098-9201 Configuration guide

Popular Security Sensor manuals by other brands

big ideas PW15 instruction manual

big ideas

big ideas PW15 instruction manual

B.E.G. Luxomat PD2-DIM Series Installation and operating instructions

B.E.G.

B.E.G. Luxomat PD2-DIM Series Installation and operating instructions

SCHUNK OPR 061-221 Assembly and operating manual

SCHUNK

SCHUNK OPR 061-221 Assembly and operating manual

Motorline professional MD150 installer and user manual

Motorline professional

Motorline professional MD150 installer and user manual

Homematic IP HmIPW-SMI55 Installating instruction and operating manual

Homematic IP

Homematic IP HmIPW-SMI55 Installating instruction and operating manual

LST 16589 Specification sheet

LST

LST 16589 Specification sheet

ARCURE BLAXTAIR 3 user manual

ARCURE

ARCURE BLAXTAIR 3 user manual

Innovative Technology CCE 15 Short manual

Innovative Technology

Innovative Technology CCE 15 Short manual

Uniden R4 user manual

Uniden

Uniden R4 user manual

UTL UTLCD1 instruction manual

UTL

UTL UTLCD1 instruction manual

Ludlum Measurements 44-7 manual

Ludlum Measurements

Ludlum Measurements 44-7 manual

RKI Instruments 35-3010RK-06-02 manual

RKI Instruments

RKI Instruments 35-3010RK-06-02 manual

Fluke Amprobe UAT-620 Technical data

Fluke

Fluke Amprobe UAT-620 Technical data

Solutions UWT NivoGuide 8100 Technical Information/Instruction manual

Solutions

Solutions UWT NivoGuide 8100 Technical Information/Instruction manual

Protecta AC350A User instruction manual

Protecta

Protecta AC350A User instruction manual

Jung Observer 220 Operation manual

Jung

Jung Observer 220 Operation manual

Pilz PSEN ml b 1.1 operating manual

Pilz

Pilz PSEN ml b 1.1 operating manual

DELTA DORE TYXAL DF installation guide

DELTA DORE

DELTA DORE TYXAL DF installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.