Getting Started
DKIT-03 Lamp Module Starter Kit
Simply Automated, Incorporated
Important note: each lamp module has a specific device ID #. You can find the device ID # on
the box the lamp module came packaged in and also on the back of each lamp module. One
lamp module has device ID #14 and the other has device ID #15. This is important information, it
relates to operation with the Input/Output Module and Pocket Programmer (sold separately).
Section 2.b. Installation of the I/O Module
Locate a 110 VAC power receptacle in (or near) the alarm panel and plug-in the I/O Module. The
I/O Module has 3 pre-configured inputs (3 low voltage 4-5VAC/DC or 2 contact closure) to turn
on/off the 2 lamp modules. Refer to User Guide in box the I/O Module came packaged in or see
http://simply-automated.com/documents/452-0003-0001_RevE_UMI_UserGuide_090512.pdf.
The discrete low voltage or contact closure trigger outputs of the security panel need to be
connected to the proper terminals of the I/O Module.
Input 1: Low Voltage (only), terminals 6 and 7
Turns on/off first lamp module (#14)
Input 2: Contact, terminals 9 and 10
OR
Input 2: Low Voltage, terminals 8 and 9
Turns blinking on/off for all lamp modules
Input 3: Contact, terminals 15 and 16
OR
Input 3: Low Voltage, terminals 14 and 15
Turns on/off all lamp modules
Note: Low voltage inputs are differential (i.e.
positive or negative polarity does not matter).
Pre-Configured Input 1: Low voltage input. Turns on first lamp module (#14) when trigger is
enabled. Turns off first lamp module when trigger is disabled. Used for delay entry/exit (lights on
for entry, off for exit), arm/disarm acknowledgement, door strike or motion sensor interface.
Installer needs to program security panel for each trigger interface. Low voltage wires (provide 0
Volt ‘off‘ or 4-5 Volt ‘on’ trigger) from security panel connect to input terminals 6/7 of the I/O
Module.
Pre-Configured Input 2: Low voltage or contact closure input. Turns on both lights and flashes
when triggered is enabled. Turns off lights and stops flashing lamp modules when trigger is
disabled. Used for fire, intrusion or panic alarms. Installer needs to program security panel for
alarm type and trigger. Low voltage wires (provide 0 Volt ‘off’ or 4-5 Volt ‘on’ trigger) from
security panel connect to input terminals 8/9, or contact closure wires (provide open – ‘off’ or
closed – ‘on’ trigger) connect to input terminals 9/10 of the I/O module.
Pre-Configured Input 3: Low voltage or contact closure input. Turns on both lights when trigger is
enabled. Turns off both lights when trigger is disabled. Used for fire, intrusion or panic alarms.
Installer needs to program security panel for alarm type and trigger. Low voltage wires (provide 0
Volt ‘off’ or 4-5 Volt ‘on’ trigger) from security panel connect to input terminals 14/15, or contact
closure wires (provide open – ‘off’ or closed – ‘on’ trigger) connect to input terminals 15/16 of the
I/O Module.
6108 Avenida Encinas, Suite B, Carlsbad, CA 92011 USA
Technical Support: www.simply-automated.com or 800-630-9234
452-0003-1001 Rev. B Revised: July 7, 2009