The flow sensor is an indispensable ally for
your Sinopé smart water valve since it detects
invisible* leaks that can occur when pipes
break in walls and ceilings.
POSITIONING YOUR FLOW SENSOR
The flow sensor must be placed before the Sedna valve on the main water pipe to perform
an optimal work. In addition, it is important to take into account the arrow on the sensor,
which indicates the direction of the water flow and thus, the preferred direction to properly
position the device during installation.
* The flow sensor detects abnormal flow rates of
2L/min (FS4220 ¾ inch version) and 4L/min
(FS4421 1 inch version).
IMPORTANT: Installation of the
flow sensor should be performed
by a certified professional in
accordance with local and
national building codes.
If possible, to improve reading accuracy,
install the flow sensor at least 6 '' (15 cm)
from an upstream elbow.
INSTALLATION OF YOUR FLOW SENSOR
Close the water inlet valve. Open the
hot and cold water taps located near
the device to reduce the water
pressure.
Place the flow sensor directly on the Sedna
valve or just before the water inlet valve.
Depending on your plumbing, additional
parts may be required (not included).
Plug the flow sensor wire into the valve.
Open the water supply to make sure there
are no leaks.
ADD YOUR FLOW SENSOR
TO NEVIWEB
1. Once the flow sensor is connected to your
2nd generation Sedna valve, go to the
Neviweb app.
2. From the All Devices page, select your 2nd
generation Sedna valve.
3. Press the Settings icon.
4. Once on the Settings page, go to the
"Flow Sensor" section.
5. Select the FS4220 or FS4221 model (¾" and
1" respectively) and configure the other
settings as needed. Press Save.
TECHNICAL SPECIFICATIONS
Compatibility:
compatible with the 2nd
generation Sedna Sinopé valve
Water temperature: ≤ 60 °C (140 °F)
Material: Stainless steel 304, lead free
Hydraulic withstand pressure:
1.75 MPa (244 PSI)
FS4220
Diameter and connection: NPT ¾ in
Flow range: 2-45 L/Min
FS4221
Diameter and connection: NPT 1 in
Flow range: 4-45 L/Min
Standards : Conforms to ANSI B120.1
660-3150-0025-A
1
3
2
4
27 mm 34 mm
1 NPT
3/4 NPT
3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the
components of their products against defects in
material and workmanship for a 3 year period from
the date of purchase, under normal use and service,
when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any
transportation costs that may be incurred by the
consumer. Nor does it cover a product that has been
improperly installed, misused or accidentally
damaged. The obligation of Sinopé Technologies
Inc., under the terms of this warranty, will be to supply
a new unit and this releases the manufacturer from
paying the installation costs or other secondary
charges linked to replacing the unit or the
components.
For more information, visit our Website:

Other manuals for FS4220

1

This manual suits for next models

1

Popular Accessories manuals by other brands

Rice Lake MSI-8000 Operation manual

Rice Lake

Rice Lake MSI-8000 Operation manual

Kobold Heinrichs HPC Series Supplementary Operating Manual

Kobold

Kobold Heinrichs HPC Series Supplementary Operating Manual

UFESA FLEXY-HEAT CIN COMFORT instruction manual

UFESA

UFESA FLEXY-HEAT CIN COMFORT instruction manual

Philio PAT05 manual

Philio

Philio PAT05 manual

Pepperl+Fuchs NJ4-12GM-N-5M instruction manual

Pepperl+Fuchs

Pepperl+Fuchs NJ4-12GM-N-5M instruction manual

Campbell LWS instruction manual

Campbell

Campbell LWS instruction manual

Philips DLA66044D brochure

Philips

Philips DLA66044D brochure

New Life Radiology MQI006-0 Use and maintenance manual

New Life Radiology

New Life Radiology MQI006-0 Use and maintenance manual

SIKA induQ VMI Series operating manual

SIKA

SIKA induQ VMI Series operating manual

Philips 2G350A2H Specifications

Philips

Philips 2G350A2H Specifications

LocknCharge UV ONE manual

LocknCharge

LocknCharge UV ONE manual

HyQuest Solutions IoTa LTE-M manual

HyQuest Solutions

HyQuest Solutions IoTa LTE-M manual

SFG R303A Series user manual

SFG

SFG R303A Series user manual

Festo SDAP-...-M50-Series operating instructions

Festo

Festo SDAP-...-M50-Series operating instructions

Hytronik HCD418-I Installation and instruction manual

Hytronik

Hytronik HCD418-I Installation and instruction manual

Advantech WISE-2410X-E21 user manual

Advantech

Advantech WISE-2410X-E21 user manual

Tascam US-122MKII release note

Tascam

Tascam US-122MKII release note

Seeley CW3 installation manual

Seeley

Seeley CW3 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.