TECHNICAL SPECIFICATIONS
DISCONNECT YOUR
THERMOSTAT FROM A
CONTROL4 HOME
AUTOMATION SYSTEM
CONNECT YOUR THERMOSTAT TO A CONTROL4 HOME AUTOMATION SYSTEM
USER SETTINGS
SETTINGS WHICH CAN BE MODIFIED ON
THE DEVICE DIRECTLY
Operating voltage: 120 / 208 / 240 / 277 Vac, 50 / 60 Hz
Maximum load:
1800 W @ 120 V / 15 A
3120 W @ 208 V / 15 A
3600 W @ 240 V / 15 A
4155 W @ 277 V / 15 A
Setpoint range: 5 °C to 36 °C (41 °F to 97 °F)
Display range: 0 °C to 50 °C (32 °F to 99 °F)
Resolution: ±0.5 °C (±1 °F)
Storage: -20 °C to 50 °C (-4 °F to 122 °F)
Operation: 0 °C to 50 °C (32 °F to 122 °F)
Communication protocol: Zigbee 3.0
Frequency: 2.4 GHz
Transmission power: +20 dBm
Receiver sensitivity: -108 dBm
Get the setpoint to its minimum and hold the button for 10 seconds to
access the menu.
Press the or button to change the setting,
Press the and buttons simultaneously to save and go to the next
parameter. Continue to press until the end of the list to exit the menu.
10 sec.
All the parameters of your thermostat can be programmed through the
interface of your Control4 controller.
However, if your thermostat is not connected to your controller and you
wish to change the temperature format, you need to:
Transmitter Module IC :
22394-ZBM1501 / FCC ID:2AK2T-ZBM1501
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the
following two conditions:
(1) this device does not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected. Consult the dealer or an experienced radio/TV technician for help.
3-year limited warranty
SINOPÉ TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3 year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product subjected to misuse or
accidental damage. The obligation of SINOPÉ TECHNOLOGIES INC., under the
terms of this warranty, will be to supply a new unit and this releases the
manufacturer from paying the installation costs or other secondary charges linked
to replacing the unit or the components.
TH1500ZB-C4
Installation Guide
Smart Double
Pole Thermostat
For more information, visit our website:
660-0737-0004-A
Initiate the connectivity session of your Control4
controller by referring to the device's user guide.
12
4
Connect your thermostat to the network by pressing
simultaneously on the and buttons.
3
On the thermostat display:
Blinks = Connecting
Remains lit = Connected
If the connectivity fails, the symbol will disappear from the
display. Refer to our website to troubleshoot the unit.
Connect all your thermostats the same way, by going to
the next closest thermostat.
When all the thermostats are connected, close the
connectivity session of your Control4 controller.
To disconnect your thermostat
from the Control4 controller,
press the and buttons
simultaneously during 10
seconds. The symbol will
disappear from the display.
Gateway
2nd
1st
3rd
10 sec.
INSTALL YOUR THERMOSTAT
Unlock and lift the
thermostat cover.
Use the screws to secure the
thermostat to the electrical box.
Replace the cover and lock. Power up the thermostat.
Warnings
Make sure to turn off the heating circuit at the main electrical
panel to avoid any risk of electric shock.
The installation of this thermostat should be made by a
certified electrician and must be installed in conformity
with the national and local Electrical Codes.
Use the provided connectors
to connect the load/line wires
located on the back of the
thermostat.
12
345
Make sure to firmly tighten the
wire connectors for a secure
connection. A loose connection
can be a fire hazard.
Red (Line)
Red (Load)
Black (Load)
Black (Line)
1) Load power
Reading of the load power connected to the thermostat, featured in watts.
Max
Load
Temp
Min
Temperature format
°C or °F (Default: °C)
Minimum setpoint
5 °C to 36 °C (Default: 5 °C)
Maximum setpoint
5 °C to 36 °C (Default: 36 °C)
Load power
0 W to 4155 W (2)
4
Name Parameters & settings Display