Skin for life Pure O2 User manual

Setup
INSTRUCTIONS:
Pure O2 Portable Machine
Back View
Cord Placement
• Power Input is in the back of
the machine
• Insert adapter in the back at
the base of the machine
• Cord - DC power adapter
has a 2 prong plug.
Placement Guidelines
On/Off Switch
Two Buttons
• LED light on/off switch only
powers the LED light hand
pieces
• O2 on/off switch only
powers airbrush for
dispersing oxygen
LED light
Hand Pieces
• The white cord from the LED
light hand pieces have a
5 pin “Din Plug.” View the
LED socket to guide you for
perfect alignment before
inserting the plug into the LED
socket
Airbrush
Attachment
• Thread silver hose adapter to
the base of the oxygen gun
• Insert the black hose firmly
into the front of the machine
into the black fitting.
• When removing black hose
use index finger and thumb
to press down on the ring of
black fitting and pull hose to
remove
Thread silver
adapter to base
of oxygen gun
End of black hose. Insert
into the front tube fitting
for O2 Gun
F622019 Rev.2

Things to
MAINTAIN:
Pure O2 Portable Machine
THINGS to Try Before You Call
Oxygen Infusion Airbrush
OXYGEN AIRBRUSH
Clogging -
Look for “signs” of product build up due to
improper maintenance -
• Lever - may not pull back when dispersing
Oxygen Infusion activator phase 2 or may
only disperse air
• Fluid Adjustment - may not adjust easily.
May be hard to turn
• Nozzle Tip - may see white or a slight
bluish tone of residue around the tip.
Checking Needle for Build Up
• Remove the back of the oxygen gun - view
image
• End of needle will be apparent - view image
• Loosen the “Acorn Nut” partially. Pull the
needle out from the back
• Soak needle in “Oxygen Infusion Cleaner”
for 24 hours or if unavailable use “Hot
Water”. You may use a “Scrub Pad” to
remove residue build up
• After 24 hours make sure needle is
completely “DRY”. Reinsert needle and
tighten “Acorn Nut”
• Replace the back and tighten. If necessary
adjust “Fluid Adjustment Knob” for
lever/trigger control
• Test Oxygen Airbrush
Cup with
Lid - Only
Use
Oxygen
Infusion
activator
phase 2
Fluid Adjustment
Knob adjusts
the lever/trigger
for proper
dispersement of
Oxygen Infusion
activator
phase 2
Lever/Trigger
Air Only - Pull
back
Dispersing
Product - Push
down and Pull
Back
Nozzle
Tip
Fluid
Adjustment may
be necessary to
have complete
control of lever/
trigger
Unscrew here
to remove the
back of the gun
End of Needle
pull to remove
Acorn Nut
partially
loosen before
removing
needle
Skin for Life recommends purchasing a SECOND (backup)
oxygen airbrush in case the initial oxygen airbrush may not be
repaired due to improper assembly or maintenance.
F622019 Rev.2
Popular Airbrush manuals by other brands

XPOtool
XPOtool 34151 user manual

Paasche Airbrush
Paasche Airbrush TGX-VISION Instructions-parts list

Iwata
Iwata High Performance Plus Series Owner's operating instruction manual

paasche
paasche MIL instructions

Iwata
Iwata Revolution HP-AR Manual & parts guide

Model Babette
Model Babette Airbrush Laser Pointer user manual