SMART RTM-ATCA-F125 Quick start guide

RTM-ATCA-F125
Installation and Use
P/N: 6806800K30J
November 2020

© 2020 SMART Embedded Computing™, Inc.
All Rights Reserved.
Trademarks
The stylized "S" and "SMART" is a registered trademark of SMART Modular Technologies, Inc. and “SMART Embedded
Computing” and the SMART Embedded Computing logo are trademarks of SMART Modular Technologies, Inc. All other names
and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. These materials are
provided by SMART Embedded Computing as a service to its customers and may be used for informational purposes only.
Disclaimer*
SMART Embedded Computing (SMART EC) assumes no responsibility for errors or omissions in these materials. These
materials are provided "AS IS" without warranty of any kind, either expressed or implied, including but not limited to,
the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. SMART EC further does
not warrant the accuracy or completeness of the information, text, graphics, links or other items contained within these
materials. SMART EC shall not be liable for any special, indirect, incidental, or consequential damages, including without
limitation, lost revenues or lost profits, which may result from the use of these materials. SMART EC may make changes to
these materials, or to the products described therein, at any time without notice. SMART EC makes no commitment to update
the information contained within these materials.
Electronic versions of this material may be read online, downloaded for personal use, or referenced in another document as a
URL to a SMART EC website. The text itself may not be published commercially in print or electronic form, edited, translated,
or otherwise altered without the permission of SMART EC.
It is possible that this publication may contain reference to or information about SMART EC products, programming, or services
that are not available in your country. Such references or information must not be construed to mean that SMART EC intends
to announce such SMART EC products, programming, or services in your country.
Limited and Restricted Rights Legend
If the documentation contained herein is supplied, directly or indirectly, to the U.S. Government, the following notice shall apply
unless otherwise agreed to in writing by SMART Embedded Computing.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (b)(3) of the Rights in
Technical Data clause at DFARS 252.227-7013 (Nov. 1995) and of the Rights in Noncommercial Computer Software and
Documentation clause at DFARS 252.227-7014 (Jun. 1995).
SMART Embedded Computing, Inc.
2900 S. Diablo Way, Suite 190
Tempe, Arizona 85282
USA
*For full legal terms and conditions, visit www.smartembedded.com/ec/legal

Table of Contents
RTM-ATCA-F125 Installation and Use (6806800K30J) 3
About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.2 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.3 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.4 Ordering and Support Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2 Hardware Preparation and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.2 Unpacking and Inspecting the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
2.3 Environmental and Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.3.1 Environmental Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
2.4 RTM Installation and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.4.1 Installing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
2.4.2 Removing the RTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3 Controls, LEDs, and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.2 Face Plate Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.2.1 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
4 Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.2 Management Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.2.1 FRU Serial EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.2 Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2.4 I2C Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.3 1Gbps SFP Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

4 RTM-ATCA-F125 Installation and Use (6806800K30J)
Table of Contents
4.3.1 Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
4.3.2 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3.3 SFP Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3.3.1 I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.3.3.2 SFP Status Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.3.3.3 SFP Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.4 10Gbps SFP+ Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.4.1 Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.4.2 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.3 BCM8747 Configuration Flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.4 Transmitter Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.5 BCM8747 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.4.6 SFP+ Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.6.1 I2C Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.6.2 SFP+ Status Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.4.6.3 SFP Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.5 GPS Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.6 FPGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.6.1 Front-blade Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.6.2 SFP/SFP+ Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
4.6.3 BCM8747 Control and Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6.4 SFP I2C Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6.5 Reset Handling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6.6 BCM8747 SPI Flash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.6.7 FPGA Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.6.8 FPGA Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.7 Reset Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.8 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.8.1 Power-good Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
4.8.2 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
A Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
A.1 SMART Embedded Computing Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

List of Figures
RTM-ATCA-F125 Installation and Use (6806800K30J) 5
Figure 3-1 Face Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 4-1 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 4-2 1GB Base Channel Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 4-3 Fabric 10 GB Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

List of Figures
6 RTM-ATCA-F125 Installation and Use (6806800K30J)

List of Tables
RTM-ATCA-F125 Installation and Use (6806800K30J) 7
Table 1-1 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 1-2 RTM-ATCA-F125 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 2-1 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 4-1 Temperature Sensor Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 4-2 PCF 8574 Port Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 4-3 I2C Bus Address Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 4-4 Front-Blade Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 4-5 SFP Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 4-6 10Gbps SFP+ Front-Board Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 4-7 SFP+ Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 4-8 FPGA Configuration Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 4-9 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table A-1 SMART EC Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

List of Tables
8 RTM-ATCA-F125 Installation and Use (6806800K30J)

RTM-ATCA-F125 Installation and Use (6806800K30J) 9
About this Manual
Overview of Contents
This manual is divided into the following chapters and appendices.
Chapter 1, Introduction on page 21 describes the main features of the RTM.
Chapter 2, Hardware Preparation and Installation on page 25 installation prerequisites and
the installation itself.
Chapter 3, Controls, LEDs, and Connectors on page 33 describes external interfaces such
as connectors and LEDs.
Chapter 4, Functional Description on page 35 contains a block diagram of the RTM and
provides some information on the IPMI functionality of the RTM.
Appendix A, Related Documentation on page 47 lists SMART EC user manuals that are
related to the RTM and the ATCA-F125.
Abbreviations
This document uses the following abbreviations:
Abbreviation Definition
AMC Alarm Management Controller
ARP Address Resolution Protocol
ATCA Advanced Telecom Computing Architecture
BIX Base Interface Switch
CP-TA Communications Platforms Trade Association
FIX Fabric Interface Switch
IO Input/Output
PICMG PCI Industrial Computer Manufacturers Group
PCI Peripheral Component Interconnect
RTM Rear Transition Module
SPI Serial Peripheral Interface

10 RTM-ATCA-F125 Installation and Use (6806800K30J)
About this Manua
l
About this Manual
Conventions
The following table describes the conventions used throughout this manual.
Notation Description
0x00000000 Typical notation for hexadecimal numbers (digits are 0 through F), for
example used for addresses and offsets
0b0000 Same for binary numbers (digits are 0 and 1)
bold Used to emphasize a word
Screen Used for on-screen output and code related elements or commands.
Sample of Programming used in a table (9pt)
Courier + Bold Used to characterize user input and to separate it from system output
Reference Used for references and for table and figure descriptions
File > Exit Notation for selecting a submenu
<text> Notation for variables and keys
[text] Notation for software buttons to click on the screen and parameter
description
... Repeated item for example node 1, node 2, ..., node 12
.
.
.
Omission of information from example/command that is not necessary at
the time
.. Ranges, for example: 0..4 means one of the integers 0,1,2,3, and 4 (used
in registers)
| Logical OR
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury
Indicates a hazardous situation which, if not avoided, may result in minor
or moderate injury

About this Manual
RTM-ATCA-F125 Installation and Use (6806800K30J) 11
Summary of Changes
This manual has been revised and replaces all prior editions.
Indicates a property damage message
Indicates a hot surface that could result in moderate or serious injury
Indicates an electrical situation that could result in moderate injury or death
Indicates that when working in an ESD environment care should be taken
to use proper ESD practices
No danger encountered, pay attention to important information
Notation Description
Part Number Publication Date Description
6806800K30J November 2020 Update Table 1-1 Standards Compliance for 62368-1
compliance.
6806800K30H January 2020 Rebrand to SMART Embedded Computing template.
6806800K30G May 2016 Removed Declaration of Conformity.
6806800K30F September 2015 Updated Chapter 1.2StandardCompliance,onpage15,
updated Safety Notes English, and Sicherheitshinweise.
6806800K30E August 2014 Updated Declaration of Conformity.

12 RTM-ATCA-F125 Installation and Use (6806800K30J)
About this Manua
l
About this Manual
6806800K30D April 2014 Re- branded to Artesyn Template.
6806800K30C December 2012 Updated Chapter 1, Standard Compliances, on page 23.
6806800K30B March, 2012
Updated Chapter 1, Features, Chapter 3, Overview,
Chapter 4, Functional Description, Safety Notes, and
Sicherheitshinweise
6806800K30A June, 2011 GA Version
Updated on page 26.
Part Number Publication Date Description

RTM-ATCA-F125 Installation and Use (6806800K30J) 13
Safety Notes
This section provides warnings that precede potentially dangerous procedures throughout
this manual. Instructions contained in the warnings must be followed during all phases of
operation, service, and repair of this equipment. You should also employ all other safety
precautions necessary for the operation of the equipment in your operating environment.
Failure to comply with these precautions or with specific warnings elsewhere in this manual
could result in personal injury or damage to the equipment.
SMART Embedded Computing (SMART EC) intends to provide all necessary information
to install and handle the product in this manual. Because of the complexity of this product
and its various uses, we do not guarantee that the given information is complete. If you
need additional information, ask your SMART EC representative.
The product has been designed to meet the standard industrial safety requirements. It must
not be used except in its specific area of office telecommunication industry and industrial
control.
Only personnel trained by SMART EC or persons qualified in electronics or electrical
engineering are authorized to install, remove or maintain the product.
The information given in this manual is meant to complete the knowledge of a specialist and
must not be used as replacement for qualified personnel. Keep away from live circuits
inside the equipment. Operating personnel must not remove equipment covers. Only
factory authorized service personnel or other qualified service personnel may remove
equipment covers for internal subassembly or component replacement or any internal
adjustment.
Do not install substitute parts or perform any unauthorized modification of the equipment or
the warranty may be voided. Contact your local SMART EC representative for service and
repair to make sure that all safety features are maintained.
Electrical Interference
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by SMART EC could void the user's
authority to operate the equipment. Board products are tested in a representative system
to show compliance with the above mentioned requirements. A proper installation in a
compliant system will maintain the required performance.

14 RTM-ATCA-F125 Installation and Use (6806800K30J)
Safety Notes
Safety Notes
To ensure EMC protection use only shielded cables when connecting peripherals to assure
that appropriate radio frequency emissions compliance is maintained. Installed blades
must have the face plates installed and all vacant slots in the shelf must be covered.
Installation
Damage of the RTM and Additional Devices and Modules
Incorrect installation or removal of additional devices or modules may damage the RTM or
the additional devices or modules.
Before installing or removing additional devices or modules, read the respective
documentation.
Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the RTM can damage
circuits or shorten its life.
Before touching the RTM or electronic components, make sure that you are working in an
ESD-safe environment.
Damage of the RTM
Incorrect installation of the RTM can cause damage of the RTM.
Only use handles when installing/removing the RTM to avoid damage/deformation to the
face plate and/or PCB.
Damage to RTM/Backplane or System Components
Bent pins or loose components can cause damage to the RTM, the backplane, or other
system components.
Carefully inspect the RTM and the backplane for both pin and component integrity before
installation.
SMART EC and our suppliers take significant steps to ensure there are no bent pins on the
backplane or connector damage to the blades/RTMs prior to leaving the factory. Bent pins
caused by improper installation or by inserting blades with damaged connectors could void
the SMART EC warranty for the backplane or blades.
System Damage
WARNING: The intra-building port (s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-building port (s)
of the equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as
intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require

Safety Notes
RTM-ATCA-F125 Installation and Use (6806800K30J) 15
isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring. The intra-building
port(s) of the equipment or subassembly must use shielded intra-building cabling/wiring
that is grounded at both ends.
Operation
Damage of the RTM
High humidity and condensation on the RTM surface causes short circuits.
Do not operate the RTM outside the specified environmental limits. Make sure the RTM is
completely dry and there is no moisture on any surface before applying power.
Environment
Always dispose of used blades, system components and RTMs according to your country’s
legislation and manufacturer’s instructions.
SFP/SFP+ Modules
Personal Injury and Damage of the RTM and SFP/SFP+ Modules
Installing and using SFP/SFP+ modules which are not fully certified and which do not meet
all relevant safety standards may damage the RTM and the SFP/SFP+ modules and may
lead to personal injury.
Only use and install SFP/SFP+ modules which are fully certified and which meet all
relevant safety standards.
Personal Injury
Optical SFP/SFP+ modules may be classified as laser products. When installing and using
any of these SFP/SFP+ modules, the regulations which correspond to the respective laser
class apply to the whole RTM. Not complying to these regulations may lead to personal
injury.
When installing and using optical SFP/SFP+ modules which are classified as laser
products, make sure to comply to the respective regulations.
Eye Damage
Optical SFP/SFP+ modules may emit laser radiation when no cable is connected. This
laser radiation is harmful to your eyes.
Do not look into the optical lens at any time.

16 RTM-ATCA-F125 Installation and Use (6806800K30J)
Safety Notes
Safety Notes
SFP/SFP+ Module Damage
The optical port plug protects the optical fibres against dirt and damage. Dirt and damage
can render the SFP/SFP+ module inoperable.
Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+
module. When no cable is connected, cover the port with an optical port plug.

RTM-ATCA-F125 Installation and Use (6806800K30J) 17
Sicherheitshinweise
Dieses Kapitel enthält Hinweise, die potentiell gefährlichen Prozeduren innerhalb dieses
Handbuchs vorrangestellt sind. Beachten Sie unbedingt in allen Phasen des Betriebs, der
Wartung und der Reparatur des Systems die Anweisungen, die diesen Hinweisen
enthalten sind. Sie sollten außerdem alle anderen Vorsichtsmaßnahmen treffen, die für den
Betrieb des Produktes innerhalb Ihrer Betriebsumgebung notwendig sind. Wenn Sie diese
Vorsichtsmaßnahmen oder Sicherheitshinweise, die an anderer Stelle diese Handbuchs
enthalten sind, nicht beachten, kann das Verletzungen oder Schäden am Produkt zur Folge
haben.
SMART Embedded Computing (SMART EC) ist darauf bedacht, alle notwendigen
Informationen zum Einbau und zum Umgang mit dem Produkt in diesem Handbuch bereit
zu stellen. Da es sich jedoch um ein komplexes Produkt mit vielfältigen
Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen
Informationen nicht garantieren. Falls Sie weitere Informationen benötigen sollten, wenden
Sie sich bitte an die für Sie zuständige Geschäftsstelle von SMART EC.
Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf
ausschließlich für Anwendungen in der Telekommunikationsindustrie und im
Zusammenhang mit Industriesteuerungen verwendet werden.
Einbau, Wartung und Betrieb dürfen nur von durch SMART EC ausgebildetem oder im
Bereich Elektronik oder Elektrotechnik qualifiziertem Personal durchgeführt werden. Die in
diesem Handbuch enthaltenen Informationen dienen ausschließlich dazu, das Wissen von
Fachpersonal zu ergänzen, können dieses jedoch nicht ersetzen.
Halten Sie sich von stromführenden Leitungen innerhalb des Produktes fern. Entfernen Sie
auf keinen Fall Abdeckungen am Produkt. Nur werksseitig zugelassenes
Wartungspersonal oder anderweitig qualifiziertes Wartungspersonal darf Abdeckungen
entfernen, um Komponenten zu ersetzen oder andere Anpassungen vorzunehmen.
Installieren Sie keine Ersatzteile oder führen Sie keine unerlaubten Veränderungen am
Produkt durch, sonst verfällt die Garantie. Wenden Sie sich für Wartung oder Reparatur
bitte an die für Sie zuständige Geschäftsstelle von SMART EC. So stellen Sie sicher, dass
alle sicherheitsrelevanten Aspekte beachtet werden.
EMV
Das Produkt wurde in einem SMART EC Standard system getestet. Es erfüllt die für digitale
Geräte der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-
Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen
angemessenen Schutz vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie
Industriegebieten gewährleisten.

18 RTM-ATCA-F125 Installation and Use (6806800K30J)
Sicherheitshinweise
Sicherheitshinweise
Das Produkt arbeitet im Hochfrequenzbereich und erzeugt Störstrahlung. Bei
unsachgemäßem Einbau und anderem als in diesem Handbuch beschriebenen Betrieb
können Störungen im Hochfrequenzbereich auftreten.
Benutzen Sie zum Anschließen von Peripheriegeräten ausschließlich abgeschirmte Kabel.
So stellen Sie sicher, dass ausreichend Schutz vor Störstrahlung vorhanden ist. Die Blades
müssen mit der Frontblende installiert und alle freien Steckplätze müssen mit Blindblenden
abgedeckt sein.
Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich
Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt
werden,angemessene Maßnahmen durchzuführen.
Installation
Beschädigung des RTMs und von Zusatzmodulen
Fehlerhafte Installation von Zusatzmodulen, kann zur Beschädigung des RTMs und der
Zusatzmodule führen.
Lesen Sie daher vor der Installation von Zusatzmodulen die zugehörige Dokumentation.
Beschädigung von Schaltkreisen
Elektrostatische Entladung und unsachgemäßer Ein- und Ausbau von Blades/RTMs kann
Schaltkreise beschädigen oder ihre Lebensdauer verkürzen. Bevor Sie Blades/RTMs oder
elektronische Komponenten berühren, vergewissern Sie sich, dass Sie in einem ESD-
geschützten Bereich arbeiten.
Beschädigung des RTMs
Fehlerhafte Installation des RTMs kann zu einer Beschädigung des RTMs führen.
Verwenden Sie die Handles, um das RTM zu installieren/deinstallieren. Auf diese Weise
vermeiden Sie, dass das Face Plate oder die Platine deformiert oder zerstört wird.
Beschädigung des RTMs, der Backplane oder von System Komponenten
Verbogene Pins oder lose Komponenten können zu einer Beschädigung des RTMs, der
Backplane oder von Systemkomponenten führen.
Überprüfen Sie daher das RTM sowie die Backplane vor der Installation sorgältig und
stellen Sie sicher, dass sich beide in einwandfreien Zustand befinden und keine Pins
verbogen sind.

Sicherheitshinweise
RTM-ATCA-F125 Installation and Use (6806800K30J) 19
SMART EC und unsere Zulieferer unternehmen größte Anstrengungen um sicherzustellen,
dass sich Pins und Stecker von Blades/RTMs vor dem Verlassen der Produktionsstätte in
einwandfreiem Zustand befinden. Verbogene Pins, verursacht durch fehlerhafte
Installation oder durch Installation von Blades/RTMs mit beschädigten Steckern kann die
durch SMART EC gewährte Garantie für Blades und Backplanes erlöschen lassen.
Beschädigung des Systems
Warnung: Die intra-Gebäude Port (s) des Geräts oder Baugruppe ist für den Anschluss an
den inner Gebäude oder unbelichteten Verdrahtung oder Verkabelung nur. Die intra-
Gebäude Port (s) des Geräts oder Baugruppe muss nicht metallisch mit Schnittstellen, die
an der Außenanlage (OSP) oder dessen Verkabelung anschließen angeschlossen
werden. Diese Schnittstellen sind für die Verwendung als intra Gebäude Schnittstellen nur
entworfen, (Typ 2 oder Typ 4 Ports wie in GR-1089 beschrieben) und erfordern Isolierung
von der freiliegenden OSP-Verkabelung. Die Zugabe von primären Schutz nicht
ausreichenden Schutz, um diese Schnittstellen metallisch mit OSP Verdrahtung verbinden.
Die intra-Gebäude Port (s) des Gerätes oder einer Unterbaugruppe müssen abgeschirmte
innerGebäudeVerkabelung / Verdrahtung, die an beiden Enden geerdet ist zu verwenden.
Betrieb
Beschädigung des Blades
Die RJ-45-Stecker an der Frontblende sind für Anschlüsse vom Typ Twisted-Pair Ethernet
(TPE) oder E1/T1/J1 vorgesehen. Der Anschluss eines E1/T1/J1-Interfaces an einen
Ethernet-Stecker kann zur Zerstörung des Blades führen.
Stellen Sie daher sicher, dass TPE-Stecker an Ihrem Arbeitsplatz eindeutig als
Netzwerkstecker gekennzeichnet sind.
Stellen Sie sicher, dass die Länge eines Kabels, welches an den RJ-45-Stecker
angeschlossen ist, 100 m nicht überschreitet.
Stellen Sie sicher, dass der TPE-Stecker ausschließlich mit einem Safety-Extra-
Low-Voltage-Stromkreis (SELV) verbunden ist.
Wenden Sie sich bei Fragen an ihren Systemadministrator
Beschädigung am Telefon
Die CH2und CH3 Stecker sind mit einem durchgestrichenem Telefonhörer markiert. Wenn
Sie an diese Stecker ein Telefon anschließen, kann Ihr Telefon beschädigt werden.
Benutzen Sie für diese Stecker ausschließlich das CABLE-8001-CLK-3/10 Kabel.
Umweltschutz
Entsorgen Sie alte Batterien und/oder Blades/Systemkomponenten/RTMs stets gemäß der
in Ihrem Land gültigen Gesetzgebung.

20 RTM-ATCA-F125 Installation and Use (6806800K30J)
Sicherheitshinweise
Sicherheitshinweise
SFP/SFP+ Modules
Gefahr von Verletzungen sowie von Beschädigung des RTMs und SFP/SFP+-
Modulen
Die Installation und der Betrieb von SFP/SFP+-Modulen, welche nicht zertifiziert sind und
welche nicht den Sicherheitsstandards entsprechen, kann Verletzungen zur Folge haben
sowie zur Beschädigung des RTMs und von SFP/SFP+-Modulen führen.
Verwenden Sie daher nur SFP/SFP+-Module, die zertifiziert sind und die den
Sicherheitsstandards entsprechen.
Verletzungsgefahr
Optische SFP/SFP+-Module können als Laserprodukte klassifiziert sein. Wenn Sie solche
SFP/SFP+-Module installieren und betreiben, so gelten die entsprechenden
Bestimmungen für Laserprodukte für das gesamte RTM. Werden diese Bestimmungen
nicht eingehalten, so können Verletzungen die Folge sein.
Wenn Sie SFP/SFP+-Module betreiben, die als Laserprodukte klassifiziert sind, stellen Sie
sicher, dass die entsprechenden Bestimmungen für Laserprodukte eingehalten werden.
Verletzungsgefahr der Augen
Optische SFP/SFP+-Module können Laserstrahlen aussenden, wenn kein Kabel
angeschlossen ist.
Blicken Sie daher nicht direkt in die Öffnung eines SFP/SFP+-Moduls, um Verletzungen
der Augen zu vermeiden.
Beschädigung von SFP/SFP+-Modulen
Die Schutzkappe eines SFP/SFP+-Modules dient dazu, die sensible Optik des SFP/SFP+-
Modules gegen Staub und Schmutz zu schützen.
Entfernen Sie die Schutzkappe nur dann, wenn Sie beabsichtigen, ein Kabel
anzuschließen. Andernfalls belassen Sie die Schutzkappe auf dem SFP/SFP+-Modul.
Other manuals for RTM-ATCA-F125
1
This manual suits for next models
1
Table of contents
Other SMART Computer Hardware manuals

SMART
SMART MOD IIB Manual

SMART
SMART MOD 8 User manual

SMART
SMART MP7035 User manual

SMART
SMART MOD II 1 User manual

SMART
SMART RTM-ATCA-7360-HDD User manual

SMART
SMART FS2020 User manual

SMART
SMART MOD IIC Manual

SMART
SMART AFT660 User manual

SMART
SMART CENTER SURROUND 3X User manual

SMART
SMART EXM556 Manual
Popular Computer Hardware manuals by other brands

Diablotek
Diablotek F8025 Specifications

ekwb
ekwb EK-FC790 Installation and mounting manuals

EK-Quantum
EK-Quantum Vector RTX 3080/3090 Backplate user guide

AvalonMiner
AvalonMiner A Series Disassemble guide

Advantech
Advantech ACP-7000 user manual

Cypress Semiconductor
Cypress Semiconductor CY7C1380DV25 Specification sheet