SmartLine SL1600 User manual

www.weathermatic.com
ADSL1600_revG
1
4. Install a wall anchor in the marked position then install the bracket
onto the anchor using one of the mounting screws provided (do
not tighten screw fully yet). The center screw will automatically
level the bracket on the wall. After level is set, mark the other
mounting holes and install the remaining wall anchors.
5. Install other screws through bracket into anchors (except for
bottom center screw) and tighten all screws.
6. Align the three retainers on back of the controller housing onto
the mounting bracket and lower it into place.
7. For additional security, install a
bottom center mounting screw from
the inside of the controller. Drive the
provided screw through the mounting
notch located just below the zone
modules to secure the controller to
the bracket.
Step 2B: Installing Without Quick Mount Bracket
1. Determine mounting height for easy viewing and be sure to mount
low enough for field wires to reach controller wiring terminals and
test post at top of controller.
2. Install a wall anchor in the desired
location. This will be for the top/center
hanger hole of the controller.
3. Install one of the mounting screws
provided into the wall anchor.
4. Hang the controller on the mounting
screw by positioning the controller on
the head of the mounting screw. Check
the controller for level, then drive a 2nd
screw into the “notch” inside the bottom/
center location to mark position for second anchor. Remove
controller from top keyhole and install second anchor and then
remount controller and tighten both screws to secure unit.
Step 3: SLM4 Module Installation
1. The SL1600 controller is equipped with
one 4-zone module (SLM4). Additional
SLM4 modules may be added to expand
capacity to 16 zones. The SL1620 has
20 fixed zones; the SL1624 has 24 fixed
zones. The SLM4 module is useable only
on the SL1600.
2. The SL1600 controller will automatically
recognize the additional zones as they are installed. No special
programming or resetting is required to initialize the modules.
3. You can insert or remove a module without removing power from
the controller.
4. To install a module,
push the module into
the channels until you
feel it lock in place. To
remove a module, push
DOWN on the center
release panel on the top
of the module and use the top tab to pull it out.
TEST
AC1
SEN
SEN
COM
P/MV
RED
BLACK
SILVER
Step 1: Controller Installation
All SL1600 controller housings are designed for indoor or outdoor
installation. Your SL1600 controller can be located in any convenient
spot such as inside the garage or on an outside wall. It is recommended
that you choose a location where the irrigation system will not be
spraying directly on the controller, in the event the housing door is
left open.
1. Open the controller’s front door, then open the control panel of
your SL1600 controller.
2. Remove the control
panel from the SL1600
controller housing by
pushing upward and
outward to remove
from the hinges, then
set the control panel
aside in a safe place.
3. Mount the SL1600
controller with or
without the SL1600 controller Quick Mount bracket.
Step 2A: Installing With Quick Mount Bracket
(recommended)
1. Determine mounting height for easy viewing and be sure to mount
low enough for field wires to reach all controller wiring terminals
and test post at top of controller.
2. Place the mounting bracket
against the wall so that the word
“CONTROLLER SIDE” is visible
and the open ends of the housing
retainers are pointing upward.
3. Using one of the mounting screws
(or a pencil) mark the location
onto the wall of the top/center
hole (see photo).
TEST
AC1
SEN
SEN
COM
MV/P
RED
BLACK
SILVER
TEST
AC1
SEN
SEN
COM
MV/P
RED
BLACK
SILVER
A
C Wiring Cavity
with panel removed
MOV (Metal
Oxide Varistor)
Installed SLM4 Modules
AC Wiring
Cavity panel
Optional SLHUB
Communication Hub
Transformer Te st
Post
SL1600 Interior Layout
Optional
SLHUB
CONTROLL
THIS
SL1600 Controller
Installation Instructions
TEST
AC1
SEN
SEN
COM
P/MV
RED
BLACK
SILVER
Note: Modules must be
inserted in the sequence
of numbered zones. Do
not leave any gaps in
module positions.

www.weathermatic.com
ADSL1600_revG
2
Step 4: AC Power Wiring
1. Plug the included 6-foot line cord into a 120VAC outlet. (E-SL1600
units for international use are prewired for 230VAC.)
2. Do NOT use a switch controlled wall outlet for operating an
irrigation controller.
Alternate Wiring
If you are mounting your SL1600 controller outdoors or local electrical
codes require hard wiring, proceed with the following steps.
Warning: Connecting the
SL1600 controller to the
primary power should be
done by a licensed electrician
following all local codes.
To prevent electrical shock,
make sure all supply power
is turned OFF at the breaker
before connecting these wires.
Electrical shock can cause
severe injury or death. This
controller is not intended for use by children. Do not allow children
to play with the controller.
1. Remove the screws that secure the AC Wiring Cavity Panel. This
will allow access to the transformer wiring.
2. Disconnect the existing line cord connected to the transformer
wires.
3. For use with conduit, simply remove the line cord knockout. To do
this, use a small, flat screwdriver blade in the slot of the knockout
on the underside of the controller housing. Tap out the knockout
with a hammer. Install the conduit and wiring. Discard the line cord.
For 120VAC operation, using wire nuts, make the wire connections
indicated in the chart below.
For 230VAC operation, using wire nuts, make the wire connections
indicated in the chart below.
4. Replace the AC Wire Cavity Panel and secure with the screws.
5. Return to the breaker box and turn on the circuit breaker. Verify
that the controller no longer displays “no AC.” This indicates that
the AC power is on.
Transformer
Wire color AC Input Wire Note
Wire
Connections
for 120VAC
Black Neutral
White 120VAC Hot
Red DO NOT USE-230VAC (cover with wire nut)
Green/Yellow Earth Ground (typically green wire)
Wire
Connections
for 230VAC
Black Neutral
White DO NOT USE-120VAC
Red 230VAC Hot (cover with wire nut)
Green/Yellow Earth Ground
Step 5: 24VAC Valve Wiring
WARNING: Never mix 24VAC and
high voltage wiring in the same
conduit.
• For solid wires, simply push
to insert the stripped end of
valve wire into the module
connector.
• For stranded wires, use a
small screwdriver blade to
push back the orange slide
lock trigger first, then insert
the stranded wire while holding the trigger in the open position.
When you release the orange slide trigger, the wire will lock in
place.
SL1600 Controller
Installation Instructions
• Knockouts: The SL1600
controller provides several
convenient knockouts for
your choice of routing for
valve and accessory 24VAC
wiring. The knockouts
should be removed by
striking with a hammer
and screwdriver inwards,
toward the inside of the
housing.
• COM (Valve Common):
Connect the Valve Common wire to the COM terminal.
• MV/P (Master Valve/Pump
Terminal): Connect one wire to the
COM position and the second wire
to the MV/P position. Polarity is
not important. Note that the total
current of the activated Pump
Start Relay AND valve(s) cannot
exceed the maximum output
current (default is 1.0A).
• SEN (Rain/Freeze/Wind Sensor):
If you are using an optional rain,
freeze, or wind sensor, use the SEN
terminals for these devices. There
is no polarity required for these
wires. Remove and discard the
factory installed wire jumper.
• Zone Wires: Connect a zone wire
to a terminal on the SLM4 Module.
Your SL1600 controller can power
a total of 3 valves concurrently or
a total of 2 valves with one master
valve. Take caution when
running a pump start
relay so maximum output
current does not exceed
1.0A. To locate a zone,
touch zone wire to the
TEST POST and determine
which zone valve is ON.
Note that the TEST POST
is HOT even when the
control panel is not in the
housing.
9V Battery Installation
(optional)
SL1600 controllers with firmware versions later than 1.10 do not require
a battery for clock time retention. A 9-volt battery may be installed for
operating the display when the panel is open or for programming while
the panel is outside the housing.
Step 6: Control Panel Installation
1. With the controller and optional SLW On-Site Weather Station
installation complete, re-insert the control panel into the housing.
To do this, hold the operating panel at a 90 degree angle from
the housing (see photo at right) and position the top of the panel
slightly toward the housing and slip the top post into the top
hinge, then push the bottom post into the lower hinge. The panel
should now swing open and close freely on the hinges.
2. The SL1600 controller will automatically restore power and
communication to the control panel as soon as it is firmly closed.
No ribbon cable is required.
Installation is complete! Proceed to your Owner’s Manual to program
your SL1600 controller.
RESET
VDC
Battery
Compartment
Back of Control Panel
9V Battery installed
TEST
AC1
RED
BLACK
SILVER
SEN
SEN
COM
P/MV
TEST
AC1
TEST
AC1
SEN
SEN
COM
P/MV
RED
BLACK
SILVER
Test Pos
t
Ty pical
Wiring
Note: To remove
wires, push back
the orange slide
trigger using a small
screwdriver and then pull out
the wire to remove.
Note: Your SL1600
controller utilizes
screwless terminals
for fast installation.
Note: If you are NOT
using an optional rain
or freeze sensor, the
wire jumper must be in
place for your valves to turn ON.
The jumper must also be in place
if you are using the SLW weather
station. SLW WEATHER STATION
DOES NOT ATTACH TO THESE
TERMINALS.
Help Desk: 888-484-3776
Monday – Friday 8:00 am – 5:00 pm CST
Online: support.weathermatic.com
Email: support@weathermatic.com
Note: Please make
all high voltage
(120V) connections
in AC Wiring Cavity
or UL approved junction box.
Any high voltage connections
made elsewhere in the controller
cabinet is a violation of the UL
listing.
Other manuals for SL1600
1
Other SmartLine Controllers manuals