5
OPERATION
Temperature Setting
The temperature control has + or - buttons. By experimenting with different settings, you will find the temperature most
comfortable to you. The thermostat will automatically turn the tub on as the temperature falls below the set temperature and
turn off when it reaches the set temperature.
Jets
When the tub water is at the set temperature, the jets will not be on. If you wish to use the tub, the “JETS” button on the
control panel activates a timer that overrides the temperature you have selected. This turns the jets on for a 15 minute period.
If you want to stop the jets within that 15 minute period, press the “JETS” button again. During use (bi-fold lid off and air
valve opened), the water temperature usually drops enough to allow the thermostat to keep the HydroMate running after the
15 minute period. If the HydroMate stops after 15 minutes the “JETS” button may be pressed again to keep the
HydroMate running.
Filtration
The tub automatically runs if it determines that it requires filtration. When the tub is running in the filtration cycle, the filter
icon will glow. The digital controls are set to run two 15 minute filtration cycles in a 24 hour period. These will run every 12
hours and are set when the hot tub is first plugged in. The filtration cycle will only run if there has been no heat call in the
prior 12 hours. If there has been a heat call, the filtration cycle will be skipped saving you money.
*Patent Pending Programming
Ground Fault Circuit Interrupter (GFCI)
The Softub cord is fitted with a ground fault circuit interrupter (GFCI), a very important safety feature. The GFCI shuts off the
electricity immediately if there is a short in the cord or HydroMate . This plug fits conventional 110 Volt outlets found in
homes. It is recommended that the GFCI be tested prior to each use.
The test procedures are as follows:
1. Push the “TEST” button on the GFCI and the light on the GFCI should go off. If the light fails to go out, DO NOT USE
YOUR SOFTUB. CALL YOUR DEALER FOR INSTRUCTIONS.
2. If the GFCI tests okay, firmly push the “RESET” button back into place and the HydroMate should resume power. If
“RESET” button fails to reset properly or if power does not return the HydroMate , DO NOT USE YOUR SOFTUB.
CALL YOUR DEALER FOR INSTRUCTIONS.
3. If the GFCI trips by itself at any time, firmly press the “RESET” button back into place and perform the above tests. If
this happens more then once, DO NOT USE YOUR SOFTUB. CALL YOUR DEALER FOR INSTRUCTIONS.
Ozone
Ozone is a gas that is used as an aid to the sanitizer in the water. Ozone helps to oxidize any contaminants in the water. The
tub automatically cycles ozone into the water for the first 15 minutes of every heat call as well as during a filtration cycle,
should one be deemed, necessary. Additionally, the ozone will run for 1 hour duration during the next filtration or heat cycles
after the usage of the tub. The ozone is controlled by a solenoid that automatically opens and closes an air pathway to the
body of water. In the event of a manual activation (depression of the jets button) the ozone is automatically turned off and will
not run until the next heat call or filtration cycle. This prevents the immediate contact with ozone as well as delaying the
automatic opening of the air control, which leaves the control of the air to the discretion of the user.
Air Control
The main air control valve is located on the control panel of the motor unit. To open the air control, rotate the knob counter-
clockwise one quarter of a turn. To close the air control, rotate the knob clockwise. Each jet can be individually directed by
rotating the head of the jet. See your Softub Dealer for optional jets to customize your Softub.
®
®
®
®
®
®