SOLE LR-OL User manual

11
THE CONNECTED IRRIGATION EXPERT
LR-OL
QUICK
INSTALLATION
GUIDE

12
The LR-OL is a Bluetooth®/ LoRaTM controller that centralizes the control
of its garden equipment (lighng, swimming pool, fountain) from a single
applicaon. Simple and praccal, it is the ideal soluon to ingeniously
illuminate your garden.
The LR-OL can be controlled by bluetooth or paired with an LR-MB10
or LR-MB30 (Wi-Fi/LoRa relay) or an LR-BST.
PRESENTATION
DOWNLOADING
1. On your smartphone and/or tablet,
go to the «App Store» or «Google Play».
2. Search «MySOLEM» in the search bar.
Étape 1
3. Download MySOLEM applicaon.
MySOLEM
4. Once installed, acvate the Bluetooth® on your smartphone and/or tablet.
CREATE AN ACCOUNT
To benet from all LR-OL advantages, please create a MySOLEM account.
1. Launch MySOLEM app from your smartphone and/or tablet.
2. Go to «My account» by typing on icon.
3. Follow the steps described on the app.
GET INSTALL

13
PAIRING
1. Remove the lower hatch from the LR-OL to reveal the terminal block.
3. Start the MySOLEM app from your smartphone and/or tablet.
Step 2
2. Plug in the 220V/24Vac power supply provided.
5. Choose the LR-OL from the list of available controllers.
7. Follow the steps described on the app to complete combinaon of your
LR-OL.
6. (Oponal) Set a name and security key for your controller and press the
«Validate» buon.
Note: To idenfy your LR-OL among the nearby controllers available, refer to
the «Default name» present on its label on the back of the product.
4. Press the «Add a Controller» buon or the «+» buon.
Security key
The security key allows to protect your controller. You can dene it during the
step 6 of the «ASSOCIATION» or access to further informaon by clicking on
the icon at the top right of your screen.

14
LR-MB PAIRING
Step 3
To opmize the LoRaTM connecon between the LR-MB10/30 and the LR-OL,
test the LoRa connecon by following steps 6 and 7. It is advisable to combine
all your LR-OL near the LR-MB before installing them separately.
2. Tap the icon at the top right of your screen to access
product informaon.
4. Select the LR-MB10/30 relay you want to use.
7. Press the buon to start the test.
3. Tap «Remote Access».
6. Go back to «Remote access» screen of LR-OL, previously seen.
1. Select the previously installed LR-OL controller.
5. Validate the operaon by pressing the «Send» buon
or at the boom of your screen.
Once the combinaon is complete, you can test the connecon between your
LR-MB10/30 and your LR-OL:
Note:
- The «Established Connecon» message indicates that the connecon is
reliable.
- The message «No established connecon» indicates that it is necessary
bring your LR-OL closer to the LR-MB10/30 or inversely.

15
ASSOCIATION LR-BST
1. On the app, select your LR-BST, and switch to pairing mode
3. Tap the icon at the top right of your screen to access product informa-
on.
4. Press «Remote Access».
2. Select the previously installed LR-OL controller.
5. Select the original LR-BST from the list.
7. Click on the buon to start the test.
6. Go back to «Remote access» screen of LR-OL, previously seen.
Once the combinaon is complete, you can test the connecon between your
LR-BST and your LR-OL

16
INSTALLATION
Step 4
Several types of installaon are possible for your LR-OL.
Choose the example that you think is best for your situaon.
The LR-OL product has 4 relays (250V 16A), which can connect up to 3500 W
on a single line.
To avoid overheang and deterioraon of the device, it is not necessary to
exceed 4000 W distributed over the 4 relays.
The use of LED bulbs requires plugging in a power contactor (Schema No.3)
from a power of 150W LED bulbs.
1. A single line used with switch
You can parallel a back-and-forth switch with the programmer’s relay. Only
constraint, when the switch back and forth will be in the on posion no acon
will be possible with the programmer.
Bleu
Interrupteur
Rouge / Marron
Switch
Blue
Red/Brown

17
2. Simple installaon without power contactor
Bleu
Pompe
< 400W
Pompe
< 400W
< 400W
Terre
Rouge
Pompe > 400W
A1
3. Simple installaon with power contactor
When there is a greater need for power, including starng (e.g., a pool pump
with a power of more than 400W), you can inteleave a power contactor or
water heater delay between the controller and your device.
Make the connecon by following the 3 steps described below.
Pump Pump
Pump

18
What are the features required for the Bluetooth® product to work?
Android 4.3 and top phones and tablets equipped with Bluetooth Smart 4.0
and higher. Apple iPhone or iPad with iOS 9.0.
How can I resume the associaon or start-up procedure from scratch?
To resume an inializaon procedure, simply unplug and reconnect the power
supply.
If my device is no longer powered, do I lose the programs?
No, they’re never lost, they’re saved in a memory.
How do I reset my device’s programming?
Open the app, enter the product, then open the sengs and select «Delete
Programs and Duraons.»
FAQ
INFORMATION ABOUT THE STATE OF LED
Green LED: Normal operaon
Flashing green LED: An acve line is underway (the number of ashes
corresponds to the number of the acvated line).
Fixed Red LED: The product is in boot mode for 2 minutes
Flashing Red LED 2 mes: The programmer has lost the me, reconnect to
re-synchronize it.
LED o: The product is not powered.

19
This symbol indicates that the power supply has a thermal protecon of 130oC.
~
The «CE» symbol indicates that this device complies with European standards
on safety, health, the environment and user protecon. Devices with the
symbol «CE» are intended for sale in Europe.
This symbol indicates that these types of electrical and electronic devices must
be disposed of separately in European countries. Don’t throw this appliance
away with your household garbage. Please use the collecon and recycling
points available in your country when you no longer need this device.
This symbol indicates that power voltage is an alternave voltage.
This symbol indicates that the power supply is intended to be used only indoors.
This symbol indicates that the power supply has a Class 2 type dual insulaon.
GENERAL INFORMATION
READ THE FOLLOWING SAFETY INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR USING THE LR-OL. BE SURE TO STRICTLY FOLLOW THE
PRECAUTIONS OF USE.
The LR-OL must be installed indoors or under cover.
Install your product so that the socket outlet base is close to the material.
The socket outlet is a cung device, if there is a problem, it must be easily
accessible at all mes. Make sure that the power outlet on which your power
transformer is connected provides protecon against over-intensies and
short circuit 16A circuit breakers. Use only the power supply provided with the
product:
INPUT: 230V ~ 50Hz OUTPUT: 24V ~ 0.75A

20
TECHNICAL FEATURES
DIMENSIONS
Width: 11 cm
Height: 14,3 cm
Depth: 4,2 cm
INSTALLATION
Indoors or under cover.
Connecon: 4 relay 250VAC 16A . 3500W Max per relay.
Temperature of use: from -20C to 60C
Qualifying humidity: 90% (relave humidity).
POWER SUPPLY :
transformer : 230V ~ 50Hz / OUTPUT : 24V ~ 0.75A 50Hz
FEATURES
Bluetooth® Smart 4.0 Low Energy [2400-2483.5]Mhz
LoRaTM radio communicaon
Permanent backup of program
Backing up the internal clock in case of a break < 30s
Table of contents
Popular Controllers manuals by other brands

UTC Fire and Security
UTC Fire and Security DET-TRONICS 95-8533 instructions

Honeywell
Honeywell 6200 Series Installation, operation & maintenance manual

FUTABA
FUTABA PS-10 BR5.2 instruction manual

Pettinaroli
Pettinaroli VM000 Technical specification

Logosol
Logosol LS-231g3SB manual

Danfoss
Danfoss ICAD 600B installation guide