About This Manual
This manual is an integral part of Solinteg MHS-3~8K series single-phase high-voltage


products.




not constitute any express or implied guarantee.
1
7.3 Advanced Setting …………………………………………………………… 58
 ……………………………………… 61
7.5 Auto-Test ……………………………………………………………………… 61
7.6 Reactive Power Regulation Mode…………………………………………… 63
8.1 Monitoring Device …………………………………………………………… 66
8.2 Monitoring APP………………………………………………………………… 67
8.3 Setup APP ……………………………………………………………………… 67
9.1 Error Message ………………………………………………………………… 68
 ………………………………………………………… 73
 ………………………………………………………… 74
10.1 Technical Parameters………………………………………………………… 75
10.2 Contact Information ………………………………………………………… 84




latest manual can be found at www. solinteg.com.
※
-


This manual is applicable to electrical installers with professional qualifications and

①
with hazards.
②Knowledge of the manual and other related documents.
③Knowledge of the local regulations and directives.
Indicates a hazard with a high level of risk that, if not avoided, will result
in death or serious inju.
DANGER
Indicates a hazard with a medium level of risk that, if not avoided, could
result in death or serious inju.
WARNING
※ 1.1 How To Use This Manual
※ 1.2 Target Groups
※ 1.3 Symbols
6
User Manual
MHS-3~8K series
Indicates a hazard with a low level of risk that, if not avoided, could
result in minor or moderate inju.
CAUTION
Indicates a situation that, if not avoided, could result in equipment or
propey damage, data loss, equipment peormance degradation.
NOTICE
Indicates additional information, emphasized contents or tips that may
be helpful, e.g., to help you solve problems or save time.
NOTE
7
User Manual
MHS-3~8K series
Safety Instructions
2
①
manual strictly.
②Installers need to undergo professional training or obtain electrical related professional

③


the warranty.
④All electrical installations must conform to local electrical safety standards.
⑤
system installation and maintenance.
⑥
authority.
⑦

⑧

⑨




①
②
③Damages caused by installation and use of equipment by non-professionals or un-
trained personnel.
④Damages caused by failure to comply with the instructions and safety warnings in this
document.
⑤Damages of running in an environment that does not meet the requirements stated in
this document.
⑥

※ 2.1 Safety Notes
※ 2.2 Statement
8
User Manual
MHS-3~8K series
⑦
software codes.
⑧

⑨Any damages caused by the process of installation and operation which don't follow the
local standards and regulations.
⑩Products beyond the warranty period.
9
User Manual
MHS-3~8K series
※
-

Product Description
3
Figure 3-1 Schematic diagram of hybrid system
The system is not suitable for supplying life-sustaining medical devices.
It cannot guarantee backup power in all circumstances.
NOTICE


PV
MODULES
BATTERY
HYBRID󶀅
INVERTER
BUCK-UP󶀅
LOAD
CURRENT
TRANSFORMER
002456
UTILITY󶀅METER
FOR󶀅BILLING
PURPOSES
UTILITY󶀅
GRID
SMART
METER
ON-GRID
LOAD
SMART
METER
※ 3.1 System Introduction
Figure 3-2 Applicable grid types
MHS-3~8K
TN-S
L
N
PE
TN-C
L
PEN
MHS-3~8K
TN-C-S
L
N
PE
MHS-3~8K
TT
L
N
PE
MHS-3~8K
10
User Manual
MHS-3~8K series
3.2.2 Appearance

-
ize intelligent power management and dispatching.
3.2.1 Models




Item Terminal Note
1Display and LED panel Display the operation information and working status of
the inveer.
2 Hanger Used to hang the inveer on the wall-mounting bracket.
3 DC switch Used to safely disconnect the DC circuit.
4 DC input terminal PV connector
5Batte input terminal Batte connector
6COM1 po WiFi/LAN/4G module connector
7COM2 po Multi-function Connector (Meter/BMS/RS485/DRED)
8 On-grid output terminal Used for On-grid output cable connection
9Back-up output terminal Used for Back-up output cable connection
3.2 Product Introduction
1
2
11
User Manual
MHS-3~8K series
3.2.3 Indicator

Item Indicator Status Description
1Power and
Alarm Indicator
O No power.
Blue
Quick ashing Inveer entered self-test status.
Slow ashing Inveer entered waiting status.
Breathe ashing Inveer works normal.
Orange Breathe ashing Low batte warning, the batte power is
about to reach the SOC protection value.
Red Always on An alarm or fault is detected, view the fault
info on the display.
2Grid
Indicator
O Grid lost.
Slow ashing Inveer detected grid but not running in on-grid mode.
Always on Inveer works in on-grid mode.
3Communica-
tion Indicator
Green Always on The inveer communication is running nor-
mally.
Green Flashing The inveer communicates with EMS or
Master inveer through RS485 or CAN.
Orange Always on The inveer isn’t communicating with Solin-
teg sma meter.
Red Always on The inveer isn’t communicating with the
BMS.
4Display Display o to save power, press the button to wake up the display.
5 Button Switch display information and set parameters by sho press or long press.
1
32
4
5
12
User Manual
MHS-3~8K series
Symbol Description
To avoid the potential eects on the environment and human health as a result
of the presence of hazardous substances in electrical and electronic equipment,
end-users of electrical and electronic equipment should understand the meaning
of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsoed mu-
nicipal waste and have to collect such WEEE separately.
Please read the instructions carefully before installation.
Do not touch any internal pas of the inveer being disconnected from the mains,
batte and PV input for 10 minutes..
CE mark, the inveer complies with the requirements of the applicable CE guide-
lines.
Danger. Risk of electric shock!
The suace is hot during operation and do not touch.
Additional grounding point.
※ 3.3SymbolsOntheInveer
13
User Manual
MHS-3~8K series

-
ure the operation mode as per your preference in the App.
General Mode
In this working mode, when the power from the
PV array is sucient, PV power will supply the
loads, battery, and grid in the order ofloads
rst, batte second, and grid last.
(You can set the power to the grid to 0W when
the local grid doesn’t allow inverter power to
feed to the grid).
When the PV power is insufficient, the battery
will discharge to supply loads, and the grid will
join in if the battery is not enough to supply
loads.
PV Loads
Grid
PV Loads
Grid
※ 3.4 Operation Modes
14
User Manual
MHS-3~8K series
Peak load Shifting (Load Shifting)
Set the maximum power Pmax (kVA) contracted
with the grid.
When the load consumption is less than the
Pmax, the PV will charge the battery first, and
the grid supplies the load. When the batte is
full, PV will supply the load together with the
grid, but the batte doesn't.
When the load consumption exceeds the Pmax,
the inveer will take power from the batte and
PV to supply power to the load to compensate
for the power that exceeds the Pmax.
*To realize the “Peak load Shifting” function, the load power that exceeded Pmax has to be within the inveer
max output power, otherwise, the inveer will only output the max power which allowed.
PV Loads
Grid
PV Loads
Grid

Pload>Pmax
15
User Manual
MHS-3~8K series
UPS Mode
In this working mode, the inverter will use the
power from PV or grid to charge the battery
until it is fully charged, and as long as the grid is
there, the batte won’t discharge.
When the grid fails, power from PV and batte
will supply loads connected on the back-up side
(UPS).
PV Loads
Grid
PV Back-up Loads
Grid
X
16
User Manual
MHS-3~8K series
Economic Mode
In this working mode, you can set charge/dis-
charge power and time in the App, inveer will
use the power from PV or grid (whether to use
can be set in the App) to charge the batte in
the predetermined period.
Inveer will use power from PV and batte to
supply loads in the predetermined period and
the insucient pa will be supplied by the grid.
PV Loads
Grid
PV Loads
Grid
17
User Manual
MHS-3~8K series
O-gridMode
In the purely o-grid mode, power from PV will
supply the back-up loads rst and then charge
the batte if there's surplus power.
When the power from PV isn’t enough, the
batte will discharge to supply back-up loads
together with PV.
PV Back-up Loads
No Grid
PV Back-up Load
No Grid
18
User Manual
MHS-3~8K series


using the Back-Up function smoothly are as follows for your awareness.
①Do not connect loads that are dependent on a stable energy supply for a reliable opera-
tion.
②Do not connect the loads whose total capacity is greater than the maximum Back-Up
capacity.
③


④-

※ 3.5Back-UpandO-GridOutput



surges.
-

after receiving the device.


3.6.1 Packing List

accessories in the packing box are complete when receiving the goods.
※ 3.6 Unpacking and Storage
19
User Manual
MHS-3~8K series
DEF
GHI
ABC
Figure 3-5 Packing list
JK L
User
Manual
ON-GRID
BACK-UP
20
User Manual
MHS-3~8K series
Item Name and Quantity Note
A Inveer (1pcs)
BWall-mounting bracket (1pcs), Expansion plug set (5pcs), M5 screws (1pcs)
COn-grid connector set (1pcs) Blue
DBack-up connector set (1pcs) Black
E PV terminal (MHS-3~3.6K-30 1pairs / MHS-4.2~8K-30 2pairs)Black
FBatte terminal (1 pairs) Blue
G Meter with 1 CTs (1pcs)
HCOM2 connector set (1pcs)
IMonitoring device (1pcs)
J10m meter communication cable (1pcs), 3m batte communication cable (1pcs)
K PE terminal(1pcs)
LUser guide

①Do not dispose of the original packing case. It is recommended to store the device in
the original packing case when the device is decommissioned.
②

③
than 6 levels.

This manual suits for next models

5

Other SOLINTEG Inverter manuals

SOLINTEG OGS-3.6K User manual

SOLINTEG

SOLINTEG OGS-3.6K User manual

SOLINTEG Integ M Operating manual

SOLINTEG

SOLINTEG Integ M Operating manual

SOLINTEG MHT-25-50K User manual

SOLINTEG

SOLINTEG MHT-25-50K User manual

SOLINTEG INTEG M MHT Series User manual

SOLINTEG

SOLINTEG INTEG M MHT Series User manual

SOLINTEG MHT-4-20K Series User manual

SOLINTEG

SOLINTEG MHT-4-20K Series User manual

SOLINTEG INTEG M MHS-3-8K-30 User manual

SOLINTEG

SOLINTEG INTEG M MHS-3-8K-30 User manual

SOLINTEG M Series User manual

SOLINTEG

SOLINTEG M Series User manual

SOLINTEG INTEG M MHS Series User manual

SOLINTEG

SOLINTEG INTEG M MHS Series User manual

Popular Inverter manuals by other brands

PrimeVOLT PV 5KTL-D3/G2 user manual

PrimeVOLT

PrimeVOLT PV 5KTL-D3/G2 user manual

SDMO KOHLER PERFORM 3000 TB UK C5 Instruction and maintenance manual

SDMO

SDMO KOHLER PERFORM 3000 TB UK C5 Instruction and maintenance manual

Strend Pro RY-WT8C58-C instruction manual

Strend Pro

Strend Pro RY-WT8C58-C instruction manual

SolaX Power X3-MGA-20K-G2-LV installation manual

SolaX Power

SolaX Power X3-MGA-20K-G2-LV installation manual

Power Electronics SD 300 Series Getting started manual

Power Electronics

Power Electronics SD 300 Series Getting started manual

Tektronix TG700 Technical reference

Tektronix

Tektronix TG700 Technical reference

SMA Solar Technology Sunny Tripower 15000TL Service manual

SMA Solar Technology

SMA Solar Technology Sunny Tripower 15000TL Service manual

Fusion 782-2234 owner's manual

Fusion

Fusion 782-2234 owner's manual

Delta M100 210 Operation and installation manual

Delta

Delta M100 210 Operation and installation manual

Mitsubishi Electric FR-F802 instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-F802 instruction manual

Clenergy PV-ezRack SolarRoof installation guide

Clenergy

Clenergy PV-ezRack SolarRoof installation guide

Fusion 300W INVERTER owner's guide

Fusion

Fusion 300W INVERTER owner's guide

Avsl Mercury IPS300-12 user manual

Avsl

Avsl Mercury IPS300-12 user manual

Goodwe GW5000-MS-30 Quick installation guide

Goodwe

Goodwe GW5000-MS-30 Quick installation guide

Zeversolar Zeverlution 1000S Quick installation guide

Zeversolar

Zeversolar Zeverlution 1000S Quick installation guide

Mastervolt WHISPER 16 ULTRA user manual

Mastervolt

Mastervolt WHISPER 16 ULTRA user manual

EBARA E-SPD Series Instruction and maintenance manual

EBARA

EBARA E-SPD Series Instruction and maintenance manual

Hitachi L100DN DeviceNet Series Addendum Read this first

Hitachi

Hitachi L100DN DeviceNet Series Addendum Read this first

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.