Installation
Caution
To prevent the camera from falling, make sure to attach the supplied wire
rope.
Suitable lens
The camera is equipped with 1/2type iris components. Only a 1/2type lens is
suitable. If the lens is a C-mount type, you should install the attached C-mount
adaptor first, and then install the lens.
If the lens is a CS-mount type, the protrusion behind the mounting surface
should be 5.5 mm (/ inch) or less.
Installation of an Auto Iris Lens Connector
Install the lens connector (not supplied) when using an Auto Iris Lens.
This installation should be done only by qualified service personnel or system
installers. A lens connector is not included with this camera package.
1Cut the iris control cable at the edge of the lens connector to remove the
existing lens connector and then remove the outer cable cover as shown
in the diagram on the left.
2Solder the lens cable to the pins of the lens connector.
Caution
When you install it into a wall or a ceiling, check that the wall or the ceilingˎ
is strong enough to hold the weight of the camera including the mounting
bracket, and install it without fail. If not, the camera falls down and causes
a serious injury.
Also, check if the mounting is not loosened at least once a year. Make the
checking interval short according to use condition.
Performance will depend on the installation environment and the lensˎ
itself. For details, contact your authorized Sony dealer.
Attaching the wire rope
When you install the camera on a ceiling or a high position, be sure to attach the
supplied wire rope to prevent the camera from falling.
Attach the wire rope to the screw hole on the rear of the camera, as in the
illustration.
Note
Take care not to short-circuit the power terminal or the cable with the wire rope
when you attach it.
1Secure the wire rope to the junction box on the ceiling.
Use a screw to match the screw hole of your junction box (not supplied).
2Secure the wire rope to the wire rope mounting screw hole on the rear of
the camera using the supplied screw.
Caution
Use the supplied screws for installation. If not, the wire rope may not function
properly.
Adjusting the Camera Coverage and Focus
1 Unscrew the lens mount cap.
2 Screw in the lens, and turn it until it is secured.
3 Insert the lens plug into the LENS connector.
When fitting a manual-iris lens, omit step 3.
4Loosen the zoom ring locking screw to adjust the camera shooting
coverage.
5Tighten the locking screw to fix the zoom.
6Loosen the focus ring locking screw to adjust the focus.
7Tighten the locking screw to fix the focus.
8Press the Easy Focus button on the rear to automatically adjust the
focus.
Note
You may not achieve satisfactory focus with the Easy Focus button due to the
shooting environment.
In this condition, press and hold Easy Focus button for more than 4 seconds to
return to the default flange back position. Then, adjust the focus following
step 6 and 7.
Connection
Connecting to the Network
Connect the network cable of the camera to a router or hub in the network using
the network cable.
Connecting the Power Source
There are three ways to supply power to this camera, as follows.
12 V DCˎ
24 V ACˎ
Power supply equipment pursuant to IEEE802.3af (PoE* system)ˎ
*PoE stands for Power over Ethernet.
Note
Do not turn off the camera immediately after turning it on. Wait for at least fiveˎ
minutes before turning off the camera.
Do not connect thˎe power input cable if power is supplied by a PoE system.
Connecting to 12 V DC or 24 V AC source
Connect the power input cable of the camera to a 12 V DC or 24 V AC source.
Use a 12 V DC or 24 V AC source isolated from 100 to 240 V AC. The acceptableˎ
voltage ranges for each are as follows.
12 V DC: 10.8 V to 13.2 V
24 V AC: 19.2 V to 28.8 V
- In the USA, The product shall be powered by a UL Listed Class 2 Power
Supply Only.
- In Canada, The product shall be powered by a CSA certified Class 2 Power
Supply Only.
Use UL cable (VW-1 style 10368) for these connections.ˎ
Recommended cable
12 V DC:
CABLE(AWG) #24 #22 #20
Max. length(m(feet)) 8 (26.2) 14 (45.9) 20 (65.5)
24 V AC:
CABLE(AWG) #24 #22 #20
Max. length(m(feet)) 11 (36.1) 19 (62.3) 28 (91.9)
Connecting to the power supply equipment pursuant
to IEEE802.3af
The power supply equipment pursuant to IEEE802.3af supplies the power
through the network cable. For details, refer to the Instruction Manual of the
equipment.
Specifications
Compression
Video compression format JPEG/H.264
Audio compression format G.711/G.726/AAC
Maximum frame rate 60 fps
Camera
Signal system NTSC color system/PAL color system
(switchable)
Image device 1/1.9type CMOS (Exmor)
Effective picture elements:
Approx. 2,380,000
Synchronization Internal synchronization
Horizontal resolution 700 TV lines (monitor display ratio 4:3)
Video S/N More than 50 dB (Auto gain control maximum
rate 0 dB)
Minimum illumination View-DR Off/VE* Off/Auto gain control
maximum rate MAX/30 fps/ F1.2
50 IRE (IP) Color: 0.04 lx Black & White: 0.03 lx
30 IRE (IP) Color: 0.02 lx Black & White: 0.01 lx
* VE stands for Visibility Enhancer.
Interface
LAN (PoE) 10BASE-T/100BASE-TX, auto negotiation (RJ-45)
I/O port Sensor input: × 2, make contact, break contact
Alarm output: × 2, 24 V AC/DC, 1 A max.
(mechanical relay outputs electrically isolated
from the camera)
RS-485:RS-485(Half-duplex) terminated inside of
camera
C
CS-mount lens
5.5 (/) or less
Unit: mm (inch)
D
E
Screw (supplied)
Wire rope (supplied)
F
G
Front
Side
Unit: mm (inches)
79 (3 /)
145 (5 /)
43.5 (1 /)
56 (2 /)
147 (5 /)
73 (2 /)
74 (3)
SD memory card slot
Video output VIDEO OUT: BNC, 1.0 Vp-p, 75 ohms,
unbalanced, sync negative
Microphone input* Minijack (monaural)
Plug-in-power supported (rated voltage: 2.5 V
DC)
Recommended load impedance: 2.2 k
Line input* Minijack (monaural)
* The microphone input and the line input are switchable with operating menu.
Line output Minijack (monaural), Maximum output level:
1 Vrms
Others
Power supply 12 V DC ± 10%
24 V AC ± 20%, 50 Hz/60 Hz
IEEE802.3af compliant (PoE system)
Power consumption 6.0 W max.
Operating temperature Start temperature: 0°C to 60°C (32°F to 140°F)
Working temperature: –10°C to +60°C
(14°F to 140°F)
Storage temperature –20°C to +60°C (–4°F to +140°F)
Operating humidity 20% to 80%
Storage humidity 20% to 95%
Dimensions (w/h/d)
79 mm × 74 mm × 145 mm (3 1/8inches ×
3 inches × 5 3/4inches) not including the
projecting parts and lens
Mass Approx. 570 g (1 lb 4.1 oz)
Supplied accessories CD-ROM (Supplied programs) (1)
Wire rope (1)
Screw M4 (1)
DC 12 V/AC 24 V connector (1)
Safety Regulations (1)
Installation Manual (this document) (1)
C-mount adaptor (1)
Design and specifications are subject to change without notice.
3
1
2
4
Rib
Lens Connector (not supplied)
[English]
Rib (If the cable is thick, cut this o.)
Pin 4 DC control Drive – (Ground)
Pin 2 DC control Control +
Pin 1 DC control Control –
Pin 3 DC control Drive +