SOYAL
ACCESS CONTROL SYSTEM
®AR-881EF/AR-881EV
V110221
Command List (By WG Keyboard)
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
Exiting programming mode and enabling all device
into arming status. Including 881EF/EV, WG Reader
Enabling each device into arming status. U U=Enable target unit (0=881EF/EV , 1=WG Reader)
Node ID setting 00 NNN MMM AAA
NNN=Node ID,(001~254)
MMM=881EF/V Door Number,(001~255)
AAA=WG Reader Door Number,(001~255)
IP Address assign (Must power reset)
01 0 CCCCCCCCCCCC
default value = 192.168.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise
will disable DHCP
01 1 255255255000 Netmask
01 2 192168001254 Gateway assign
Door relay time setting 02 U TTT
U=Enable target unit (0=881EF/EV , 1=WG Reader)
TTT=Door relay time
000 (Output constantly)
001~600=1-600 Sec.;601~609=0.1~0.9Sec.
Alarm relay time setting 03 TTT TTT
=Alarm relay time
001~600=1~600 Sec.
Arming delay time setting 05 TTT Base on second, range: 001~255
Alarm delay time setting 06 TTT Base on second, range: 001~255
Master card setting 07 SSSSS EEEEE SSSSS-EEEEE=00000~15999
SSSSS= starting user address; EEEEE= ending user address
Auto-open zone setting 08 MW NN HHMMhhmm
6543217H
M=881EF/EV; W=WG Reader (0=disable; 1=enable)
NN=16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
6543217: 7 days of week -Sat/Fri/Thu/Wed/Tue/Mon/Sun
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete tags Suspend:10 SSSSS EEEEE :Suspend :Delete
SSSSS= starting user address; EEEEE= ending user address
Delete: 10 SSSSS EEEEE
Recover tag 11 SSSSS EEEEE SSSSS= starting user address; EEEEE= ending user address
Setting up Card or PIN mode by user address 12 UUUUU PPPP UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card or PIN)
Arming output setting 14 TTT Base on 1ms, range:1~255, default value=10,
Input 0= Timeless
Duress code setting 15 PPPP PPPP=4-digit PWD (0001-9999)
Default value:4321 ;disable PIN=0000)
Arming PWD setting 17 PPPP PPPP=4-digit PWD (0001-9999)
Default value:1234 ;disable PIN=0000)
Enabling or Disabling into arming status Card+NNNN NNNN
:Arming PWD
U=Enable target unit (0=AR-881EF/EV , 1=WG Reader)
Enabling or Disabling each device into arming status. Card+NNNN U
Enabling all device into arming status. Card+NNNN
Disabling all device into arming status. Card+NNNN
Door open waiting time 18 TTT TTT=Door open waiting time: 001~600=1~600 sec.;
default value: 15 sec.
Set the card by induction 19 UUUUU QQQQQ UUUUU=user address
QQQQQ=Card quantity(00001=Continuously inducting)
Reader additional setting 20 U DDD U=Enable target unit (0=AR-881EF/EV , 1=WG Reader)
DDD=Function default value
Lift control setting: multi-doors 21 UUUUU G LLLLLLLL UUUUU=user address;G=4 sets of lift control(0~3);
LLLLLLLL=8 assigned oor (F=0: Disable, 1: Enable)
AR-401RO16/ AR-401RO16B relay time setting 23 MMM TTT MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.
Factory setting 24 U DDD U=Enable target unit (0=AR-881EF/EV , 1=WG Reader)
DDD
:Function default value
Real time clock setting 25 YYMMDDHHMMSS YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.
9
9
9