Space Bad Boy Delta User manual

This manual contains important information relating to
manual is left with the pump operator for future reference.
Model
–
Delta
Dual Speed Spa Pump
1
year warranty
This manual contains important information relating to
the installation, and operation of this pump. Please ensure this
manual is left with the pump operator for future reference.
Bad Boy
Spa & Swimming Pool
Pumps
the installation, and operation of this pump. Please ensure this

IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety
including the following: READ AND FOLLOW ALL INSTRUCTIONS.
1.
WARNING
To
reduce the risk of injury. Do not permit children to use this product
times.
2.
WARNING
Risk of Electrical Shock. Connected only to gro
interrupter (GFCI).
3.
Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI.
4.
CAUTION
Do not bury cord. Locate cord to minimise damage from other
5.
CAUTION
R
unning parts
can cause injury. D
system is ready for operation.
6.
WARNING
To
reduce the risk of electrical shock, replace damaged cord immediately.
7.
WARNING
To
reduce
the
risk
of
electrical
located
outlet.
8.
CAUTION
This
pump
is
for
use
in
fixed
9.
Do
not
install
within
an
outer
enclosure
10.
FOR
INDOOR
USE
ONLY.
11.
SAVE
THESE
INSTRUCTIONS.
12.
Household use
only.
13.
Connection
must
be
incorporated
into
14.
In
order
to
avoid
a
hazard
due
to
inadvertent
external switching device, such as a timer,
Do not dispose of
electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous subst
groundwater and get into the food chain, damaging your health and well
GENERAL
-
These instructions are for
the
correct installation, and opt
they should be read carefu
lly.
-
These are single
-
stage centrifugal pumps designed to operate with compact hydro massage equipment, They are
equipped with a total emptying system to prevent the discharge of residual water in each stop cycle
-
V/Hz 240/50: See pump nameplat
e.
-
These units are designed to operate with clean water at maximum water temperature of 50
-
Storage temperature:
-
10
O
C ~ +50
O
C. Relative Air Humidity: 95% Max.
-
Built of top quality materials; they are subjected to strict hydraulic and
-
Correct installation is ensured by following these instructions and those of the wiring diagram; otherwise, over loads may be
produced in the motor. We decline responsibility for any damage caused by not following these instru
INSTALLATION
-
Pumps must be level upon installation, Dimensions and position of the pump for supporting and fixing the pump within this
space (Fig.3).
-
Pump must be fixed by screws on the spa shelf, and fixed with a silent block or foam pad to
glue or tie down!
-
The pump will get hot during operation, To assist cooling, the minimum distance between the pump motor and the
surrounding
structure should be, not be less then 25mm.
-
The suction pipe of the pump shoul
d be as short as possible.
-
The rating label must be visible after installation.
-
Parts containing live parts, except parts supplied with safety extra low voltage<12V, must be inaccessible to a person in the
Spa.
-
Class I appliances must be permanently
control devices, must be located or fixed so that they cannot enter or fall into the bath.
PIPE ASSEMBLY
-
The maximum inle
t water pressure is
-
The suction pipes shoul
d have a diameter equal to or larger than that of th
loss of head and improves efficiency. The suction and discharge pipes should not be placed above the pump in all cases.
-
Ensure a good seal on all connectors
electrical.
-
Do not re
-
use old hose or connections. Replace with new hose and fittings.
ELECTRICAL CONNECTIO
N
-
The electrical installation should have a multiple separation sys
-
For continued protection against possible electric shock this unit is to be mounted to the base in accordance with the
installation instructions.
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety
precautions should always be
including the following: READ AND FOLLOW ALL INSTRUCTIONS.
reduce the risk of injury. Do not permit children to use this product
unless
they
are
closely
Risk of Electrical Shock. Connected only to gro
unding type receptacle protected by a ground fault circuit
Contact a qualified electrician if you cannot verify that the receptacle is protected by GFCI.
Do not bury cord. Locate cord to minimise damage from other
equipment & n
earby objects.
can cause injury. D
o not make the electric
pump
live
before
the
pipeline
has
reduce the risk of electrical shock, replace damaged cord immediately.
electrical
shock,
do
not
use
an
extension
cord
to connect
to
electric
supply;
fixed
-
installed
bath
tubs & Spas;
it
is
not
suitable
for swimming pools.
enclosure
or
beneath
the
skirt
of
a
hot
tub
unless so
marked.
into
fixed
wiring
in
accordance with
NZ wiring
regulations.
inadvertent
resetting
of
the
thermal
cut
-
out,
this appliance must not be supplied through an
external switching device, such as a timer,
or
connected
to
a
circuit
that
is
regularly
switched
on
and
electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous subst
ances can leak into the
groundwater and get into the food chain, damaging your health and well
-
being.
correct installation, and opt
imum performance of Bad Boy
Delta dual speed spa pumps, so
stage centrifugal pumps designed to operate with compact hydro massage equipment, They are
equipped with a total emptying system to prevent the discharge of residual water in each stop cycle
These units are designed to operate with clean water at maximum water temperature of 50
°
C.
C. Relative Air Humidity: 95% Max.
Built of top quality materials; they are subjected to strict hydraulic and
electrical control
s and are carefully verified.
Correct installation is ensured by following these instructions and those of the wiring diagram; otherwise, over loads may be
produced in the motor. We decline responsibility for any damage caused by not following these instru
Pumps must be level upon installation, Dimensions and position of the pump for supporting and fixing the pump within this
Pump must be fixed by screws on the spa shelf, and fixed with a silent block or foam pad to
lower noise and vibration. Do not
The pump will get hot during operation, To assist cooling, the minimum distance between the pump motor and the
structure should be, not be less then 25mm.
d be as short as possible.
The rating label must be visible after installation.
Parts containing live parts, except parts supplied with safety extra low voltage<12V, must be inaccessible to a person in the
Class I appliances must be permanently
connected to fixed wiring. Parts including electrical components, except remote
control devices, must be located or fixed so that they cannot enter or fall into the bath.
t water pressure is
≤0.15 MPa.
d have a diameter equal to or larger than that of th
e discharge pipes.
This assists and
loss of head and improves efficiency. The suction and discharge pipes should not be placed above the pump in all cases.
Ensure a good seal on all connectors
and unions. Avoid any water dripping onto motor, to avoid damage to motor and
use old hose or connections. Replace with new hose and fittings.
The electrical installation should have a multiple separation sys
tem with contacts opening at least 3mm.
For continued protection against possible electric shock this unit is to be mounted to the base in accordance with the
2
precautions should always be
followed,
closely
supervised
at
all
unding type receptacle protected by a ground fault circuit
earby objects.
has
been
connected &
supply;
provide
a
properly
for swimming pools.
this appliance must not be supplied through an
and
off
by
the
utility.
electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available.
ances can leak into the
Delta dual speed spa pumps, so
stage centrifugal pumps designed to operate with compact hydro massage equipment, They are
equipped with a total emptying system to prevent the discharge of residual water in each stop cycle
s and are carefully verified.
Correct installation is ensured by following these instructions and those of the wiring diagram; otherwise, over loads may be
produced in the motor. We decline responsibility for any damage caused by not following these instru
ctions.
Pumps must be level upon installation, Dimensions and position of the pump for supporting and fixing the pump within this
lower noise and vibration. Do not
The pump will get hot during operation, To assist cooling, the minimum distance between the pump motor and the
Parts containing live parts, except parts supplied with safety extra low voltage<12V, must be inaccessible to a person in the
connected to fixed wiring. Parts including electrical components, except remote
This assists and
avoids
the
loss of head and improves efficiency. The suction and discharge pipes should not be placed above the pump in all cases.
and unions. Avoid any water dripping onto motor, to avoid damage to motor and
tem with contacts opening at least 3mm.
For continued protection against possible electric shock this unit is to be mounted to the base in accordance with the

o
The
protection
of the
tripping current
not
o
Single
-
phase motors have built
-
The electric connection should be carried out by qualified staff following strictly appr
-
Be sure that the earth cable connection is correctly made.
-
Wires serving as equipotential bonding conductors shall have a cross sectional area between 2.5 mm
receptacles
.
CONTROLS PRIOR TO IN
ITIAL START
-
Verify
that the pump shaft turns freely.
-
Check that the mains voltage and frequency are according to the name plate.
-
The hydromassage assembly should be equipped with a system to prevent
level
is not
present.
-
Check the
rotating direction
of
the motor, which should concur with
-
If the motor does not start up, try to locate the problem in the table of most
provided further on
in this manual.
CAUTION: THE PUMP SHOULD NEVER OPERATE DRY.
START
-
UP
-
Ensure Spa valves are open and water is available to flow.
-
Start electrically, the pump only, when the suction and discharge pipes are connected to the corresponding inlets and
outlets.
-
Switch on pump
and
suitably adjust
MAINTENANCE AND CLEA
NING
Our pumps for
hydromassage/Spa facilities do not require any special maintenance or programming. If the pump will remain
idle for a long period of time, it is recommended to disassemble, clean and store it in a dry, well ventilated place. If the
cord is damaged,
it must be replaced by the manufacturer or its service agent or a suitably qualified person to avoid a hazard.
TROUBLE SHOOTING GUI
DE
SYMPTOM
POSSIBLE
CAUSE
Pump
Does
No
t
Turn
No
Power
To
Pump
-
Incoming power to the pump?
-
Is circuit breaker
-
Is GFCI operating properly?
-
Is the air switch plugged in?
Air Switch
Disconnected
-
Is the air switch hose connected to the pump?
-
Is the air switch hose connected to the actuator button on the tub
deck?
Pump Not
Pumping
Properly
Blockage Or
Leak
-
Is the water level in Spa adequate?
-
Jets should be pointed away from the suction inlet so air is not
forced into pump suction.
-
Is the in tub
-
Is there any debris in the pump housing?
-
Is there a leak
Low
Voltage
-
Is the proper voltage applied to the pump?
-
Is there an extension cord being used?
INSTALLATION DIAGRAM
The colours of the wires in the mains lead
correspond with the
coloured markings identifying the terminals in your
connection unit, proceed as follows. The wire which is coloured green
yellow must be connected to the terminal in the connection unit which is
marked with the letter E or by the earth symbol or colour
and
-
yellow.
Brown wire and Blue wire connected with power supply is low speed.
Black wire and Blue wire connected with power supply is high speed.
of the
system should
be
based
on
a
residual
current
device (RCD) with
not
exceeding 30mA
.
The
supply cable should comply
with
phase motors have built
-
in thermal protection.
The electric connection should be carried out by qualified staff following strictly appr
opriate NZ standards.
Be sure that the earth cable connection is correctly made.
Wires serving as equipotential bonding conductors shall have a cross sectional area between 2.5 mm
ITIAL START
-
UP
Check that the mains voltage and frequency are according to the name plate.
The hydromassage assembly should be equipped with a system to prevent
the
pump from
starting
the motor, which should concur with
that
indicated on the fan cover.
If the motor does not start up, try to locate the problem in the table of most
common faults and their possible solutions that is
CAUTION: THE PUMP SHOULD NEVER OPERATE DRY.
Ensure Spa valves are open and water is available to flow.
Start electrically, the pump only, when the suction and discharge pipes are connected to the corresponding inlets and
suitably adjust
the
jets
to
obtain
the
desired
flow
.
NING
hydromassage/Spa facilities do not require any special maintenance or programming. If the pump will remain
idle for a long period of time, it is recommended to disassemble, clean and store it in a dry, well ventilated place. If the
it must be replaced by the manufacturer or its service agent or a suitably qualified person to avoid a hazard.
CHECK
Incoming power to the pump?
Is circuit breaker
on?
Is GFCI operating properly?
Is the air switch plugged in?
Is the air switch hose connected to the pump?
Is the air switch hose connected to the actuator button on the tub
Is the water level in Spa adequate?
Jets should be pointed away from the suction inlet so air is not
forced into pump suction.
Is the in tub
suction inlet
blocked
or
covered?
Is there any debris in the pump housing?
Is there a leak
in the piping or the pump?
Is the proper voltage applied to the pump?
Is there an extension cord being used?
The colours of the wires in the mains lead
of this appliance may not
coloured markings identifying the terminals in your
connection unit, proceed as follows. The wire which is coloured green
-
and
-
yellow must be connected to the terminal in the connection unit which is
marked with the letter E or by the earth symbol or colour
ed green or green
-
Brown wire and Blue wire connected with power supply is low speed.
Black wire and Blue wire connected with power supply is high speed.
3
device (RCD) with
a rated
with
EMC
standards.
opriate NZ standards.
Wires serving as equipotential bonding conductors shall have a cross sectional area between 2.5 mm
2
terminal suitable
starting
up if
a
minimum water
indicated on the fan cover.
common faults and their possible solutions that is
Start electrically, the pump only, when the suction and discharge pipes are connected to the corresponding inlets and
hydromassage/Spa facilities do not require any special maintenance or programming. If the pump will remain
idle for a long period of time, it is recommended to disassemble, clean and store it in a dry, well ventilated place. If the
supply
it must be replaced by the manufacturer or its service agent or a suitably qualified person to avoid a hazard.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
lack of experience
and
knowledge,
unless they have been given adequate
the
appliance
by
a
person
responsible
Children should be supervised to ensure that they do not play with this appliance.
If the supply cord is damaged, it m
ust be replaced by the manufacturer, service agent or a qualified person in order to avoid
hazards.
WARRANTY
In the unlikely event you experience any issues with your Bad Boy pump, within
the dealer from whic
h you purchased the Pump who will organise repair or replacement. Ensure you have a valid proof of
purchase that clearly demonstrates the product name, its date of purchase and the place of purchase
warranty. The onus is on the pu
rchaser to return the pump to the dealer at the purchasers own expense.
ITEMS NOT COVERED BY
THE WARRANTY
-
Claims outside the
1
year warranty period
-
Fair wear & tear
-
Consumables
–
including mechanical seals, bearings, capacitors, o
-
Damage resulting f
rom misuse, neglect, improper use outside design parameters
-
Improper or inadequate installation or operation
-
Voltage spikes, corrosive chemicals
-
Unauthorised persons attempting repairs or modifications
-
When used in a commercial or non
Space Industries Ltd is not liable for any consequential losses associated with this Bad Boy Pump for whatever reason. Nor ar
they liable for any damage or injury caused directly or indirectly as a result of the operation of this Bad Boy Pump.
This limi
tation does not negate our obligations under the New Zealand Consumer Guarantees’ Act.
Space Industries Limited
16
0
Plunket Ave
Manu
kau City
Auckland 2104
Ph (09) 262 3902
reception@spaceindustries.co.n
z
www.spaceindustries.co.nz
Code
Output P2
KW
BBS
D0215
(Low speed)
(high speed)
BBSD0320
(Low speed) 0.3
0.
(high speed)1.5
2.0
BBSD04
25
(Low speed) 0.
35
0.45
(high speed)1.85
2.5
Performance Curve
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
unless they have been given adequate
supervision
or
instruction
responsible
for their
safety.
Children should be supervised to ensure that they do not play with this appliance.
ust be replaced by the manufacturer, service agent or a qualified person in order to avoid
In the unlikely event you experience any issues with your Bad Boy pump, within
1
year
of the date of purchase;
h you purchased the Pump who will organise repair or replacement. Ensure you have a valid proof of
purchase that clearly demonstrates the product name, its date of purchase and the place of purchase
.
rchaser to return the pump to the dealer at the purchasers own expense.
THE WARRANTY
year warranty period
including mechanical seals, bearings, capacitors, o
-
rings
rom misuse, neglect, improper use outside design parameters
Improper or inadequate installation or operation
Voltage spikes, corrosive chemicals
Unauthorised persons attempting repairs or modifications
When used in a commercial or non
-
domestic application, warranty is for
6 months
only.
Space Industries Ltd is not liable for any consequential losses associated with this Bad Boy Pump for whatever reason. Nor ar
they liable for any damage or injury caused directly or indirectly as a result of the operation of this Bad Boy Pump.
tation does not negate our obligations under the New Zealand Consumer Guarantees’ Act.
L
L1
L2
L3
H
HP
434
197
73
202
197
0.25
1.5
0.
38
2.0
0.45
2.5
4
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or
instruction
concerning
use
of
ust be replaced by the manufacturer, service agent or a qualified person in order to avoid
of the date of purchase;
p
lease contact
h you purchased the Pump who will organise repair or replacement. Ensure you have a valid proof of
.
This is a return to base
rchaser to return the pump to the dealer at the purchasers own expense.
Space Industries Ltd is not liable for any consequential losses associated with this Bad Boy Pump for whatever reason. Nor ar
e
they liable for any damage or injury caused directly or indirectly as a result of the operation of this Bad Boy Pump.
This manual suits for next models