manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SPAUN
  6. •
  7. Switch
  8. •
  9. SPAUN SMS 41209 WBP Owner's manual

SPAUN SMS 41209 WBP Owner's manual

• The wideband multiswitches of the SMS 41x09 WBP series are
designed to distribute the KA KU band signals from the DIRECTV 5
LNB system to 12 or 16 subscribers
• It is possible to get the HD channels using a HD capable
receiver
• The multiswitches are fed by an external wall power supply SNG 18/1000.
The maximum current is 1000 mA
Byk-Gulden-Str. 22 · D-78224 Singen
Telefon: +49 (0) 7731 - 8673-0 · Telefax: +49 (0) 7731 - 8673-17
E-Mail: [email protected] · www.spaun.de
Important: please observe the following instructions!
• The equipment described is designed solely for
use in installation of satellite receiver systems.
• Any other use, or failure to comply with these
instructions, will result in voiding of warranty cover.
• It is a must to comply with all country specific
installation and safety regulations.
• The equipment may only be installed in dry indoor
areas. Do not mount on or against highly combus
tible materials.
• The safety regulations in accordance with EN 50083-
and EN 60065 A 11 must be observed.
• Fixings: Wood screws, max. : 4,5 mm
• Connector: Screw coupling 75 (series F) to IEC 60169.
• Unused subscriber connections should be terminated
by 75 Ohm resistors (e.g. ZFR 75 DC).
SPAUN electronic confirms the keeping of the EMC
requirements in accordance to the EU product norm
EN 50083-2 and the keeping of the safety requirements
in accordance to the EU product norm EN 50083-1
by the CE sign.
The multiswitches meet the more stringent screening
requirements according to EN 50083-2, quality grade A.
All components are equipped with an earthing
terminal for connecting to the main potential equalization.
for the wideband devices
SMS 41X09 WBP, GMS 5XX09 WBP,GBK 5500 WBP, GTS
525 WB and GZR 5550/15 WB
Technical Instructions
Application example 14 V 18 V 14 V + 22 kHz 18 V + 22 kHz
Stack Plan
Ka-Low
Ku
Ka-High
99° L
101° L
99° L
99° R
101° R
99° R
103° L
119° L
103° L
103° R
110° / 119° R
103° R
SAT IF frequencies
Ka-Low
Ku
Ka-High
250 - 750 MHz
950 - 1450 MHz
1650 - 2150 MHz
Model
Art. No.
GTS 525 WB
842233
Inputs
SAT/Terr.
5
4 / 1
Outputs / Subscribers 2 x 5
Through loss
Terr.: 5 ... 160
MHz
5 dB
Through loss
SAT-IF: 250 ... 2200
MHz
6 dB
Isolation
Input / Input > 26 dB
Isolation
Output Terr.: > 20 dB
Isolation
Output SAT: > 15 dB
Isolation of taps > 26 dB
max. LNB supply current 450 mA
DC-through max. 30 V / 2 A
Ambient temperature 68 ... 122 °F
Dimensions in inch 6,14 x 6,02 x 1,46
Model
Art. No.
GZR 5550/15 WB
841155
Inputs
SAT/Terr.
5
4 / 1
Outputs / Subscribers 2 x 5
Through loss
Terr.: 5 ... 160 MHz 3 dB
Through loss
SAT: 250 ... 2200 MHz 5 dB
Tap loss
Terr.: 5 ... 160 MHz 10 dB
Tap loss
SAT-IF: 250 ... 2200 MHz 15 ... 13 dB
Isolation
trunk / trunk
trunk / tap
tap / tap
> 26 dB
> 26 dB
> 26 dB
DC-through max. 30 V / 2 A
Ambient temperature 68 ... 122 °F
Dimensions in inch 6,14 x 6,02 x 1,46
Model
Art. No.
GBK 5500 WBP
842451
Inputs
SAT/Terr.
5
4 / 1
Outputs / Subscribers 5
Trunk gain
Terr.: 5 ... 160 MHz - 2 dB
Trunk gain
SAT-IF:250 ... 2200 MHz 18 ... 28 dB
Maximum output level
250 ... 2200 MHz
35 dB IMA3/ EN 50083-3
1,25 dBm
Isolation of taps > 26 dB
max. LNB supply current 450 mA
Ambient temperature 68 ... 122 °F
Dimensions in inch 3,75 x 6,02 x 1,46
External power supply
SNG 18 / 1000
100-240V, 50-60Hz
DC 18 V / 1000 mA
The wall power supply SNG 18/1000 is
included in the delivery for the following
products: SMS41x09, GMS 5XX09
WBP, GBK 5500 WBP
Stand-By Mode
The multiswitches have a stand-by
mode. In stand-by mode the satellite IF
amplifier stages and the supply for the
LNB are switched off. If a receiver or
antenna test equipment with LNB pow-
er supply is connected to a subscriber
output, then the multiswitch switches
automatically to standard mode.
Specifications and design are subject to change due to our policy of continual technical improvement. 104056/07.08
Current-carrying unit
• Do not open or manipulate the unit!
• When working on the system always unplug the mains plug from the
wall outlet!
• Ensure adequate clearance! min. 5 cm to all sides!
• Free circulation of air must be possible to discharge the heat emitted
by the unit. Risk of overheating!
• Permissible ambient temperature -20 ...+50° C (253 K ... 323 K)
Attention:
• No liquid-filled items may be placed on top of the power supply unit.
• The power supply unit must not be exposed to dripping or
splashing water.
• The mains plug must be easily accessible and operable.
Power supply:
The wideband multiswitches have to be fed by an external wall power supply
called SNG 18/1000.
The supply voltage range is:
The supply voltage frequency may vary between:
Output voltage is 19 V with a maximum current of
LNB remote voltage:
The LNB inputs provide a voltage as shown below.
Please have a look to our stack plan to connect the LNB inputs in the right way.
100 ... 240 V ~
47 and 63 Hz
1000 mA
99°/101°L
14 V
99°/101°R
18 V
103°/101°/113°L
14 V / 22 kHz
103°/119°R
18 V / 22 kHz
12 or 16 Receiver
LNB remote current
- Total current:
- Single port current:
Current consumption:
max. current consumption from Receiver:
400 mA
400 mA
450 mA
50 mA
The LNB inputs provide a voltage as shown below.
Please have a look to our stack plan to connect the LNB inputs in the right way.
Model
Art. No.
SMS 41209 WBP
842446
SMS 41609 WBP
842447
Inputs
SAT 4
Outputs / Subscribers 12 16
Tap gain
SAT-IF: 250 ... 2200 MHz - 2 ... +7 dB
Maximum output level
250 ... 2200 MHz
35 dB IMA3/ EN 50083-3
- 14 dBm
Isolation of taps > 26 dB
max. LNB supply current 400 mA
Current consumption
from each receiver 50 mA
Ambient temperature 68 ... 122 °F
Dimensions in inch 8,31 x 5,71 x 1,54
External power supply
SNG 18 / 1000
100-240V, 50-60Hz
DC 18 V / 1000 mA
Model
Art. No.
GMS 5809 WBP
842461
GMS 51209 WBP
842452
GMS 51609 WBP
842453
Inputs
SAT/Terr.
5
4 / 1
Outputs / Subscribers 8 12 16
Tap loss
Terr.: 5 ...160 MHz 20 ... 22 dB
Tap gain
SAT-IF: 250 ... 2200 MHz 2 ... 8 dB - 6 ... 3 dB
Maximum output level
250 ... 2200 MHz
35 dB IMA3/ EN 50083-3
- 13 dBm
Isolation of taps > 26 dB
max. LNB supply current 400 mA
Current consumption
from each receiver 50 mA
Ambient temperature 68 ... 122 °F
Dimensions in inch 9,29 x 6,02 x 1,46
External power supply
SNG 18 / 1000
100-240V, 50-60Hz
DC 18 V / 1000 mA
Application example 14 V 18 V 14 V + 22 kHz 18 V + 22 kHz
Stack Plan
Ka-Low
Ku
Ka-High
99° L
101° L
99° L
99° R
101° R
99° R
103° L
119° L
103° L
103° R
110° / 119° R
103° R
SAT IF frequencies
Ka-Low
Ku
Ka-High
250 - 750 MHz
950 - 1450 MHz
1650 - 2150 MHz

This manual suits for next models

15

Other SPAUN Switch manuals

SPAUN SMS 9807 NF User manual

SPAUN

SPAUN SMS 9807 NF User manual

SPAUN SMS 9807+ NF User manual

SPAUN

SPAUN SMS 9807+ NF User manual

SPAUN SMS 607 Plus NF User manual

SPAUN

SPAUN SMS 607 Plus NF User manual

SPAUN SMS 5607+ NF User manual

SPAUN

SPAUN SMS 5607+ NF User manual

Popular Switch manuals by other brands

Cisco C-series Nexus 5010 manual

Cisco

Cisco C-series Nexus 5010 manual

Network Technologies ST-nXm-U Installation and operation manual

Network Technologies

Network Technologies ST-nXm-U Installation and operation manual

ATEN Master View SlideAway ACS-1208L user manual

ATEN

ATEN Master View SlideAway ACS-1208L user manual

Conrad RSLT4 operating instructions

Conrad

Conrad RSLT4 operating instructions

Renesas IDT 89HPES12T3G2 user manual

Renesas

Renesas IDT 89HPES12T3G2 user manual

Ocean Matrix OMX-PSW6SV instruction manual

Ocean Matrix

Ocean Matrix OMX-PSW6SV instruction manual

Cisco Catalyst 3750-E Series Software configuration guide

Cisco

Cisco Catalyst 3750-E Series Software configuration guide

B&B Electronics Elinx EIRHP305-T manual

B&B Electronics

B&B Electronics Elinx EIRHP305-T manual

Perle IDS-509G quick start guide

Perle

Perle IDS-509G quick start guide

Belkin F1DJ102PeaB user manual

Belkin

Belkin F1DJ102PeaB user manual

Quirky R-INS-TAPT-WH02 installation instructions

Quirky

Quirky R-INS-TAPT-WH02 installation instructions

infobit iShare+ user manual

infobit

infobit iShare+ user manual

LEGRAND 4 126 23 quick start guide

LEGRAND

LEGRAND 4 126 23 quick start guide

Leviton 47611-8PT Instructions for use

Leviton

Leviton 47611-8PT Instructions for use

Briggs & Stratton 1917 Installation & operator's manual

Briggs & Stratton

Briggs & Stratton 1917 Installation & operator's manual

Sensio Link-S SE781990 quick start guide

Sensio

Sensio Link-S SE781990 quick start guide

Danfoss BCP1H installation guide

Danfoss

Danfoss BCP1H installation guide

Arista 720D Series quick start guide

Arista

Arista 720D Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.