EMERGENCY TANK SHOWER TRAINING | PG. 6
INSTALLATION
How to install
OPTIONAL: The Alarm is mounted and
shipped, so that the light faces towards
the inside of the shower area. The light
needs to be removed and fl ipped so it
rests outside the shower.
Connect drainage plumbing (if desired) to
the tank over-flow outlet, located in the
back of the unit.
The Tank Shower requires connection
to a 240 volt, single phase, 50/60Hz
electrical supply, to run the immersion
heater and all other electrical components.
Any electrical options you have specified
should be supplied through a minimum
30mA Ground Fault Protection Device
(GFPD).
NOTE: It is the responsibility of the
installer to ensure all installation of
electrical equipment is performed by
suitably qualified personnel. Failure to
do so can result in injury or death.
The electrical equipment fitted to the Tank
Shower is connected to a suitable
miniature circuit breaker for the water
heater, lighting, trace heating and alarm
system as necessary. If an alarm system is
fitted, then a junction box is also fitted in
the void of the ceiling space at the front of
the shower. The junction boxes are
accessible via a removable hatch in the
ceiling. If remote alarm monitoring is
required, then a 7 core 1mm SY type cable
is also brought out to the rear of the Tank
Shower for connection to the building
Building automation system. Connections
are Hot, Neutral and Ground, with a Single
Phase supply of either 50Hz or 60Hz,
240Volts.
Connect potable water supply to water
inlet located in the back of the unit. When
the tank reaches full capacity the Ballcock
fill valve, located inside the tank will shut
o the supply automatically. The main
water supply to the tank shower should be
turned o once filling
is complete.
WATER SUPPLY: The Tank Shower should
only be supplied from a potable water
supply. See Cleaning & Maintenance
section located in this document
regarding inspection and water quality.
NOTE: To ensure a full 15 minutes of
operation, be sure to refill the tank to
full capacity every time the shower or
eyewash Is activated.
Visual and audible alarms are available to
provide a warning when the shower or
eyewash has been activated, or to indicate
changes in the water temperature/levels.
• The temperature alarm is activated by a
temperature probe inside the shower and is
connected to the graphic display or a signal
conditioning relay if no graphic display is
used.
• The water level alarm is monitored by a level
transducer fi tted to the bottom of the tank
and the alarm sound when the level drops
either by usage or testing. The signal from
the transducer is connected to the graphic
display or a signal conditioning relay if no
display is used.
• The eyewash alarm is activated by means of
a tilt switch fi tted to the operating paddle.
• The local sounder/strobe alarm will sound
for 30 minutes before it automatically
switches itself o , the strobe light however
will continue to fl ash while an alarm
condition still exists.
11 1412
13
Shown flipped inside for
shipping.
Unit is supplied standard with mechanical
style visual water level indicator located
on the front of the shroud face. This level
indicator is operated mechanically by a
ball float inside the water tank.
Remote
alarm from low
voltage
enclosure
Main electrical inlet single phase 230
volt 3.055Kw 4kva
Remote alarm
Core 1 cannon
Core 2 n/o low alarm
Core 3 n/o high alarm
Core 4-7 spare
Remove screws and flip to mount alarm,
using same holes, so light is outside the
shower area.
Main supply
isolator on rear
panel