Powering On and Connecting to a Network
Controllers must be located in a secure area and connected to a network that is protected by a security system
(firewall, etc.). Note: a Stat c IP address should be used when a controller s conf gured as a server controller.
Client controllers may use DHCP.
In most cases, the controllers IP address will have to be changed to allow the controller to be recognized by the
local network. The controller s IP address is changed as follows.
1. Connect a programming computer directly to the Ethernet port of the controller. A standard CAT-5 cable is
used for direct connection. A crossover cable is not required.
2. Assign a static IP address to the computer of 192.168.0.10.
3. The factory default IP address of the controller is 192.168.0.250. Open a web
browser, such as Google Chrome, and enter the default IP address into the
address bar.
TI : As an alternat ve to d rectly connect ng a cable, the prov ded IP Installer ut l ty can be
used to change the controller's IP address.
4. The controller s login page is displayed as shown. To login enter the default User
ID: adm n and default PW: adm n
5. Controllers can be licensed as a server or a client. After first time
login, the license page is displayed. To get a license key, first
click on the Edit button. On the next page, click on A, the Get
License Key for a S RV R or click on B, the Get Client Key for
a CLIENT. Click OK to confirm and the license key will be auto
populated. Finish by clicking C, Apply License Key and the
controller will restart.
NOTE: The controller needs to access the
Internet to obta n a l cense key.
6. When the controller is licensed for a server, after logging in, the system configuration Wizard is started. The
Wizard is a guide that can be used to collect the basic information required to set up a system. The network
settings can be configured in the Wizard or by browsing to the Network Configuration.
7. The network configurations may be also accessed through the Sitemap by first clicking the icon at the
bottom of the page, then clicking IP Address under Network Settings.
8. After entering the network information, click Save & Reboot and the
controller will reboot. Typically rebooting will take less than 2 minutes.
8. After disconnecting the
programming computer, the
controller is ready for the local
network.
NOTE: System data may be lost f the
controller s powered down
w thout perform ng Save & Reboot.