SpectraPure Eliminator RO BASIC Series User manual

2019-09-30
Reverse Osmosis Water Purification System
Eliminator RO™ BASIC
INSTALLATION AND OPERATING MANUAL
WARNING
Please read carefully before proceeding with installation. Failure to
follow any attached instructions or operating parameters may lead to
the product’s failure and possible damage to property.
Eliminator RO™ 100-BASIC
Eliminator RO™ 200-BASIC

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
2
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise without the prior written permission of SpectraPure Inc.
COPYRIGHT 2002-2019© BY SPECTRAPURE INC
ALL RIGHTS RESERVED
TABLE OF CONTENTS:
Thank You for your purchase of a SpectraPure®System. With proper
installation and maintenance, this system will provide you with high quality
water for years to come. All SpectraPure®products are rigorously tested by
us for safety and reliability. If you have any questions or concerns, please
contact our customer service department at 1.800.685.2783.
Introduction ........................................................................................................ 3
System Specifications ........................................................................................ 4
System Description ............................................................................................ 5
Single Membrane System ................................................................................. 6
Working With Push Fittings ............................................................................ 7
System Installation & Initialization ................................................................ 8
Carbon Block Filter Replacement ................................................................... 9
RO Membrane Replacement ........................................................................ 10
RO Membrane Diagnostics ...........................................................................11
Testing the Quality of the Membrane .........................................................11
Membrane Production Calculation ............................................................ 12
Tips for Long Membrane Life ....................................................................... 14
Troubleshooting Guide ..................................................................................14
One Year Limited Warranty ........................................................................ 15
Terms and Conditions ....................................................................................15
Optional Accessories ..................................................................................... 16
Replacement Parts .......................................................................................... 16

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
The Eliminator RO™ -100, -200, BASIC Systems are low-
waste RO systems which have been specifically designed for
hydroponic, vegetable and flower gardens. Purified water
grows healthier, more beautiful and longer-lasting plants than
ordinary tap water. The Eliminator RO™ Systems maximize
nutrient uptake and stabilize pH for faster growth and greater
yields while eliminating up to 99% of contaminants harmful
to plant growth. Your plants will flourish with our “better
than rain” quality water.
Dimensions: 8" H x 15" W x 5" D
The Eliminator RO™ Systems come complete with:
• 100 gallon per day, high-rejection Spectrapure advanced
thin-film membrane in the Eliminator RO™ 100 BASIC
(200 gallon per day membrane for the Eliminator RO™
200 BASIC )
• 2:1 waste ratio produces 50% less waste water
• 5 micron carbon block prefilter eliminates dirt, chlorine,
herbicides and other organic pollutants.
• 5-foot feed tubing, 6-foot product and 5-foot waste
tubing
• Garden hose adapter for tap water hookup
• One year waranty

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
4
SpectraPure® Inc.Assumes no responsibility for water damage due to
leaks. It is the user’s responsibility to determine that the system is leak-free.
SYSTEM SPECIFICATIONS:
Carbon Prefilter 5 micron carbon block prefilter
RO Membrane Type Thin-Film Composite (TFC)
Rejection Rate Greater than 94%; 98% typical
Input Water Pressure 60 psi (4.15 bar) line pressure*
Input Water Temp 77°F (25°C)
Recovery Rate 33% (i.e. 33% of the water will be collected as pure water)
Nominal Membrane Flow Rates @ 60 psi, 77° F, & 500 ppm TDS :
GPD Product Water Flow Rate Concentrate Flow Rate
100 263 ml/min 657 ml/min
200 526 ml/min 1315 ml/min
Reverse Osmosis Feed Water Requirements:
Operating Pressure* 40 – 80 psi (2.75 – 5.5 bar)
pH Range 3 – 11
Maximum Temperature 113° F (45° C)
Maximum Turbidity 1.0 NTU
Maximum Silt Density Index 5.0 (based on 15 min. test time)
Maximum Chlorine less than 0.1 ppm
Maximum TDS 1500 ppm
Maximum Hardness 16 grains (272 ppm as CaCO3)
Maximum Iron less than 0.1 ppm
Maximum Manganese less than 0.1 ppm
Maximum Hydrogen Sulfide 0 ppm
Langelier Saturation Index LSI must be negative
*Operating pressure less than 40 psi may require a booster pump:
Operating pressure greater than 80 psi may require a pressure regulator.

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SYSTEM DESCRIPTION:
The ELIMINATOR™ System gives you a continuous supply of sparkling
clear, delicious water for drinking, cooking, hydroponics, etc. Foods will
look better and taste better, too. The reliability with the ELIMINATOR™
Water Treatment System is greatly improved over other systems and costly
maintenance may be avoided. The system eliminates the need to buy
bottled water. Instead, it puts high quality water at your fingertips.
The incoming feed water from a cold water source is directed through
BLACK tubing to the 5 micron carbon block prefilter. This filter is used to
remove dirt, organics and chlorine from the feed water that can damage
the membrane. The second stage of the system is the RO membrane.
Household water pressure is used to force tap water through the
semipermeable RO membrane. The membrane only allows the purest of
water molecules to pass through it while over 98% of
most inorganic salts,
all microorganisms and almost all high molecular weight organics in the
water
are rejected and automatically rinsed from the membrane and sent
down the drain.
There is a thin capillary tube (called a Flow Restrictor) located inside the
yellow waste tubing that restricts and regulates the amount of water that
goes to drain. This water is necessary to help keep the membrane flushed
free of pollutants.
An optional manually-operated Flush Valve can be used to periodically
rinse the accumulated impurities and concentrated waste water from the
surface of the RO membrane to help increase the life of the membrane.

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
6
SINGLE MEMBRANE SYSTEM - 100 GPD & 200 GPD:
TFC RO Membrane (ELIM-MEM-100 or
ELIM-MEM- 200) & Housing
5 micron
Carbon Block
Filter
(ELIM-IL-CB-12)
Feed Water
Attaches
Here
Blue Product
Water Tubing
Yellow Waste
Water Tubing

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
WORKING WITH PUSH FITTINGS:
Push fittings are very reliable and convenient tubing connectors.
To remove the tubing from its push fitting:
1. Firmly depress and hold the push fitting collar down with your
thumbnail.
2. While the push fitting collar is depressed, pull the tubing straight out
of the push fitting. Once the tubing is removed, release the collar.
To reinsert the tubing into its push fitting:
1. Moisten the O-ring seal inside the push fitting by dripping a few drops
of clean water into the fitting.
2. Grasp the tubing near the end, and insert the tubing into the push
fitting.
3. Push the tubing into the fitting until resistance is felt, approximately
1/2 inch (12.7 mm). The tubing is now resting on the O-ring seal
inside the fitting.
4. Firmly push the tubing approximately an additional 1/4 inch (6.35
mm) further into the fitting to completely seat the line into the fitting
and past the O-ring seal.
5. Turn on the system water supply and check for leaks prior to further
use or testing. If a leak is observed, you may not have pushed the
tubing into the push fitting far enough to seal the tubing against the
O-ring. Turn off the system water supply and reseat the tubing as
described above.

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
8
SYSTEM INSTALLATION & INITIALIZATION:
1. Most of the components of this system are plastic and are subject to
damage by ultraviolet light from the sun and other sources such as
metal halide lighting.
2. Avoid installing this unit in an area where it may be subjected to
bright light or direct sunlight, as algae is more likely to thrive inside
the clear filter housings when exposed to bright light.
3. The unit must be kept out of areas that are subject to freezing
temperatures.
4. High temperatures greater than 100° F (38° C) must be avoided. If
the unit is used outside, avoid putting the system in direct sunlight
or connecting it to a garden hose that may be exposed to sunlight.
5. Attach the garden hose adapter (connected to the black
tubing) to your cold water source. Never run hot water
(greater than 113° F/45° C) through the system.
6. Place the yellow concentrate (waste) tubing and the blue
purified (product) water tubing temporarily into a drain. Do not
restrict flow from these lines.
7. Open the cold water supply valve. The pressure should not exceed 80
psi
.
8. Check the system to ensure that all fittings are tight and leak-
free before leaving the system unattended. (If anything is
leaking, contact SpectraPure for assistance.)
NOTE: It is recommended that at least 2 gallons (7.57 liters) of
purified water be discarded now before collecting purified
water for use. If the unit is not used for several days, run the
system for about 10 minutes before collecting any water.
This will flush out any stale water in the system.
9. Finish the installation by directing the yellow line to a drain.
10. Direct the blue line to a collection reservoir.

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
CARBON BLOCK FILTER REPLACEMENT:
A Carbon Filter will usually last 4-6 months, depending on the chlorine (or
chloramine) content of your tap water. The best way to determine when
your Carbon Block Prefilter needs replacement is to use a chlorine test kit.
Any chlorine level above 0.1 ppm will cause damage to the membrane
and indicates that the carbon block filter must be changed. To test for
chlorine breakthrough , collect a 10 ml sample of the concentrate from
the yellow tubing and test the chlorine concentration using test kit TK-CL-
5-KIT. If the chlorine concentration is above 0.1ppm, replace the carbon
prefilter.
NOTE: A drop in the system’s production is, in most cases, an indication
that the carbon filter has become saturated with contaminants. If
the carbon becomes plugged with sediment, it will no longer be
able to remove chlorine.
Carbon Block Filter Replacement
Materials Required: 5 micron Carbon Block Filter (ELIM-IL-CB-12),
Chlorine Test Kit (TK-CL-5-KIT)
Procedure:
1. Turn off water supply to the system.
2. Disconnect the two black tubes, remove the old filter and discard.
3. Install the new carbon block filter and reconnect the two black tubes.
4. Turn on system water supply and check for leaks.

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
10
RO MEMBRANE REPLACEMENT:
1. Turn off the water supply to the RO system. Place the system where
the membrane housing(s) can be easily accessed.
2. Remove the black tubing from the membrane feed push fitting by
depressing the collar on the fitting with your thumb and pulling the
tubing from the push fitting. You should not have to remove the blue
and yellow tubes.
3. Lift the membrane housing from the retention clips and unscrew the
membrane housing cap. This may require two people.
4. Use a pair of pliers to grasp the membrane stem and pull the membrane
from the housing.
5. Remove the black housing O-ring. Wash the empty housing with
soapy water. Rinse thoroughly with hot, clean water.
6. Insert the new membrane into the housing, with the double O-ring
end first. The O-rings and tube must fit into the recess at the bottom
of the membrane housing. When the membrane is aligned with the
recess, firmly push the membrane into the recess until it bottoms out.
7. Place the black housing O-ring on the housing rim and carefully screw
the lid back on to the base. Hand-tighten.
8. Reconnect the black tubing to the membrane feed push fitting.
9. Check for leaks.
NOTE: In some locations, extreme hard water can lead to a premature
fouling of the membrane. Those users have two options:
a.) Replace the membrane and continue to save on the water
wasted.
b.) Request a “hard water” flow restrictor configured for those
hard water locations that will extend the life of the membrane,
but increase the waste water produced.
Softened feed water can eliminate the problem described above.

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
RO MEMBRANE DIAGNOSTICS:
In order to accurately determine the condition and performance of the
RO Membrane, a conductivity tester capable of reading the tap water
conductivity (or TDS) and the product water conductivity (or TDS) would
typically be required.
You may also use an alkalinity test kit (on softened water sources) or a
hardness test kit (on non-softened water sources).
Note: All water sources are different and are subject to changes in
conductivity from season to season which could affect the TDS
reading depending on the time of the year. For this reason, we
recommend the use of a conductivity (TDS) tester in order to determine
the most accurate measurement for determining the condition of the
RO membrane.
TESTING THE QUALITY OF THE MEMBRANE:
The performance of a RO membrane is measured by its ability to reject
salts or TDS (Total Dissolved Solids). This procedure will require a TDS
Meter. SpectraPure offers several models:
ELIM-MTR-TDS-EZ HM Digital Hand-held TDS Meter
ELIM-MTR-TDS-DM1 HM Digital InLine Dual Probe TDS Meter
Procedure:
1. Measure tap water TDS. (Call it X)
2. Run the system for 15-20 minutes.
3. Rinse test instrument cell 2-3 times with RO water.
4. Measure RO water TDS directly from the blue product water line.
(Call it Y).
5. Subtract RO water TDS from tap water TDS. (X - Y)
6. Divide this quantity by tap water TDS. (X - Y) ÷ X
7. Rejection = [(X - Y) ÷ X ] ×100
TDS in the above procedure is measured in ppm or mg/l.
Important: Test the quality of the membrane once every 6 months.
(continued on next page)

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
12
MEMBRANE PRODUCTION CALCULATION:
Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars)
operating pressure, 77°F (25°C) operating temperature and with no more
than 500 ppm total dissolved solids.
Membrane output gallons per day (GPD) depends on operating pressure,
water temperature and the TDS in the feed water.
Expected GPD = Rated GPD × PCF × TCF
PCF is the pressure correction factor
TCF is the temperature correction factor
Calculation of Pressure Correction Factor (PCF): The output (GPD) from
the membrane is directly proportional to the applied pressure.
Note: The membrane is rated to produce the rated GPD at 60 psi. For any
pressure other than 60 psi the output GPD is multiplied by the PCF.
PCF = Line Pressure (in psi) ÷ 60
Calculation of Temperature Correction Factor (TCF): The output (GPD)
decreases with a decrease in temperature. This is due to water viscosity
increasing with a decrease in water temperature.
Rejection of the RO Membrane Calculation Example
1. Tap water TDS = 150 ppm (X)
2. RO water TDS = 15 ppm (Y)
3. X - Y = 135 ppm
4. (X - Y) ÷ X = 135 ÷ 150 = 0.90
5. Rejection = [ ( X - Y) ÷ X ] ×100 = 0.90 ×100 = 90%
Rejection rates less than 95% may indicate that the membrane should be replaced.

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
Membrane Output Calculation Example
What is the expected GPD from a 100 GPD System at 40 psi pressure
and 60°F water temperature?
PCF = 40 ÷ 60 = 0.666
TCF = 0.754 (from Table above)
Expected GPD = 100 × 0.666 × 0.754 = 50.2 GPD ± 15%
50.2 GPD would be the Actual Production Rate
Temperature Correction Factor Table (TCF)
°F /°C TCF °F /°C TCF °F /°C TCF
41.0 /5 0.521 59.0 /15 0.730 77.0 /25 1.000
42.8 /6 0.540 60.8 /16 0.754 78.8 /26 1.031
44.6 /7 0.560 62.6 /17 0.779 80.6 /27 1.063
46.4 /8 0.578 64.4 /18 0.804 82.4 /28 1.094
48.2 /9 0.598 66.2 /19 0.830 84.2 /29 1.127
50.0 /10 0.620 68.0 /20 0.857 86.0 /30 1.161
51.8 /11 0.640 69.8 /21 0.884 87.8 /31 1.196
53.6 /12 0.661 71.6 /22 0.912 89.6 /32 1.232
55.4 /13 0.684 73.4 /23 0.941 91.4 /33 1.267
57.2/14 0.707 75.2 /24 0.970 93.2 /34 1.304

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
14
TIPS FOR LONG MEMBRANE LIFE:
1. Replacement of 5 micron carbon block filter at least once every
6 months or when chlorine breakthrough occurs or when water
production is severly reduced. This will ensure good membrane life
and protect the membrane from chlorine damage.
2. Membrane should not be operated at lower than the specified 2:1
concentrate to purified water ratio.
3. Operating reverse osmosis systems on softened feed water greatly
reduces the chances of membrane fouling.
4. Use an optional flush valve after each use of the system to extend
membrane life.
STORAGE
1. It is recommended that you store your RO System in a cool place when
not being used.
2. Your RO System must always be protected from freezing or
temperatures above 113° F (45°C).
TROUBLESHOOTING GUIDE:
Product Water - Low Production Rate
Cause Corrective Action
Plugged prefilters Replace prefilters
Low water temperature Heat feed water or use higher GPD membrane
Low feed pressure Use booster pump or use higher GPD membrane
Fouled membrane Replace membrane

SpectraPure
®
SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
ONE YEAR LIMITED WARRANTY:
SpectraPure, Inc.®warrants the product to the original owner only to be free of defects in material and workmanship for
a period of one year from the date of receipt. SpectraPure’s liability under this warranty shall be limited to repairing or
replacing at SpectraPure’s option, without charge, F.O.B. SpectraPure’s factory, any product of SpectraPure’s manufacture.
SpectraPure will not be liable for any cost of removal, installation, transportation or any other charges which may arise
in connection with a warranty claim. Products which are sold but not manufactured by SpectraPure are subject to the
warranty provided by the manufacturer of said products and not by SpectraPure’s warranty. SpectraPure will not be
liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized
alteration or repair or, if the product was not installed in accordance with SpectraPure’s or other manufacture’s printed
installation and operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God.
SpectraPure will not be responsible for any consequential damages arising from installation or use of the product, including
any water or mold damage due to flooding which may occur due to malfunction or faulty installation, including, but not
limited to failure by installer to over- or under-tighten fittings, housings, and/or push-style fittings, or improper installation
of push-style fittings. Consumable items such as prefilters and membranes are not covered under the one year warranty.
To obtain service under this warranty, the defective system or components must be returned to SpectraPure with
proof of purchase, installation date, failure date and supporting installation data. Any defective product to be returned
to the factory must be sent freight prepaid. Documentation supporting the warranty claim and a Return Merchandise
Authorization (RMA) number must be included. SpectraPure will not be liable for shipping damages due to the improper
packaging of the returned equipment and all returned goods must also have adequate insurance coverage and a tracking
number.
SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, proliferation, spread or
any activity of “fungus”, wet or dry rot or bacteria. Such loss or damage is excluded regardless of any other cause or event
that contributes concurrently or in any sequence to the loss. We will not pay for loss or damage caused by or resulting
from continuous or repeated seepage or leakage of water, or the presence or condensation of humidity, moisture or
vapor, that occurs over a period of 14 days or more. “Fungus” and “fungi” mean any type or form of fungus or Mycota
or any byproduct or type of infestation produced by such fungus or Mycota, including but not limited to, mold, mildew,
mycotoxins, spores, scents or any biogenic aerosols.
SpectraPure will not be liable for any incidental or consequential damages, losses or expenses arising from installation,
use, or any other causes. There are no expressed or implied warranties, including merchantability or fitness for a particular
purpose, which extend beyond those warranties described or referred to above.
* The one year limited warranty does not apply to consumable items, including but not limited to, filters and
cartridges unless specifically stated above.
TERMS AND CONDITIONS:
1. Shipping charges on units or parts submitted to our facility for repair or replacement must be borne by the
registered purchaser. After repair or replacement, the factory will return the unit or part freight prepaid to the
customer.
2. We assume no warranty liability in connection with our equipment other than as herein specified.
3. This warranty is in lieu of all other warranties expressed or implied, including warranties of fitness for a particular
purpose.
4. We do not authorize any person or representative to assume for us any other obligation on the sale of our
equipment. This is the exclusive remedy and liability for consequential damages under any and all warranties which
are excluded to the extent exclusion is permitted by law.
5. Proof of original purchase date must accompany all warranty claims.
6. SpectraPure, Inc. Reserves the right to change prices without notice when necessary. All prices in the catalog are
quoted in US dollars.
7. Claims for error in quantity or condition must be made within 10 days of receipt of material. SpectraPure, Inc. will
not be responsible for any claimed shortages not reported within 10 days. Returns other than warranty claims may
be subject to 20% restocking fee.
8. SpectraPure, Inc. cannot be held liable for damage or loss to a shipment by a freight carrier. Check shipment for
damage before acceptance or note on freight bill subject to inspection for concealed damage. Consignee must file
claim. SpectraPure, Inc. will offer as much assistance as possible.
9. A complete credit check is required prior to shipping on a Net 30 basis. In the interim period during which credit
references are being evaluated, all orders must be prepaid until approved.
10. All returned checks (due to insufficient funds or closed accounts) will be subjected to a $35 penalty charge.
11. Invoices on Net 30 accounts not paid within 30 days of shipment will be considered delinquent and will accrue
Finance charges at the rate of 1.5% per month (18% per annum).

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
16
OPTIONAL ACCESSORIES:
UV PURIFIER KIT (ELIM-UV-1GPM-KIT) - Are you on a private well or other
potentially unreliable source of water? You may require a UV kit to destroy harmful
bacteria, viruses and other contaminants. Ultraviolet kills up to 99% of all viruses
and bacteria for the safest water. This kit contains everything you need to add UV
to your Eliminator™100/200/400 Reverse Osmosis System.
CLONE MASTER DI (ELIM-DI-CMCI-KIT) - Delicate plant cloning requires some
of the purest water on the planet, even beyond that produced by traditional
RO systems. By adding the SpectraPure CloneMaster DI™ stage to your existing
Eliminator™ RO system you can produce the ultra-purified water necessary for
these delicate growth challenges.
BOOSTER PUMP KITS (ELIM-BPK-100/200), (ELIM-BPK-400) - SpectraPure®
Booster Pump Kits are ideal for use on water sources with pressures below 40
psi such as private wells, gravity feed water systems and high-rise apartments. A
pressure gauge is necessary to monitor the booster pump pressure.
CARBON INLINE POST FILTER KIT - Install the Eliminator Post Filter Add-On
Kit on the product water line of your Eliminator™ 100, 200 or 400 gpd RO system
to assure elimination of hard-to-remove volatile organic chemicals and residual
chloramines. This kit includes a disposable 2” x 10” Granular Activated Carbon
cartridge with Quick Connect fittings and mounting clips.
REPLACEMENT PARTS:
Part Number Description
ELIM-IL-CB-12 5 micron Carbon Block Prefilter
ELIM-MEM-100 100 gpd TFC Membrane
ELIM-MEM-200 200 god TFC Membrane
ELIM-FR-100 Flow Restrictor for 100 gpd System
ELIM-FR-200 Flow Restrictor for 200 gpd System
ELIM-GHA-4 1/4" Garden Hose Adapter for 100/200 gpd
OTHER ACCESSORIES:
Part Number Description
ELIM-PGK Pressure Gauge Kit
ELIM-BV-4JG 1/4" Ball Valve
ELIM-MTR-TDS-EZ Handheld TDS Meter
ELIM-MTR-TDS-DM1 InLine Dual-Probe TDS Meter
ELIM-MTR-PH80 Handheld pH Meter
ELIM-FAU-SNP Quick Connect Faucet Adapter
TK-CL-5-KIT Total Chlorine Test Kit
This manual suits for next models
2
Table of contents
Other SpectraPure Water Dispenser manuals
Popular Water Dispenser manuals by other brands

Q&C
Q&C Nano user manual

Newa
Newa Duetto DJ50 Instructions and warranty

Whirlpool
Whirlpool Hot water dispenser Installation instructions and use and care guide

Kool Tek
Kool Tek FCCW2 user manual

Aquverse
Aquverse Water Cooler installation and troubleshooting instructions

Scarlett
Scarlett SC-1221 instruction manual

A.O. Smith
A.O. Smith AO-WH-SOFT-450T owner's manual

Elkay
Elkay LVRCGRN8 Series Installation, care & use manual

Everpure
Everpure 255348 manual

Aqua Computer
Aqua Computer Aquaduct 240 Operating and assembly manual

clage
clage ZIP HYDROTAP G4 BC 100/75 Operating and installation instructions

Bartscher
Bartscher 200.054 instruction manual