Spring S3 User manual

Operating Warnings S3 Pump Controller
Overview
S3
Thank you for buying an S3 Static RO Controller. This is an advanced pump controller
solution for your system and should give you complete control over water production.
Follow this manual carefully. It explains in detail how to connect and operate the pump
controller. Most connections are shown on the system diagram, however further details
are provided throughout the rest of the manual. Complete ALL wiring connections
BEFORE connecting the unit to the mains supply. Ensure the controller, sensors and
cables are firmly fixed in place before using your controller.
The S3 controls the filling side of your water tank (inlet and pure water production). The
controller has a number of other advanced features to increase ease of use and report
on the operational status of the system.
Filling
The controller opens the solenoid valve to fill the water tank until the high level float
switch activates. This is a one time operation and will stop once the tank is full. The
controller will automatically flush your RO membrane on a regular basis to keep it at
optimum performance and to increase its service life.
The controller can be configured to stop filling if the TDS is too high. This can be set to
either after the RO membrane (due to an RO failure) or after the DI vessel (if resin is
spent). It will also shutdown the fill if mains water pressure is too low.
The controller has a flowmeter to measure the amount of water used, this can also
indicate the filter life.
The controller also incorporates a pressure sensor which allows the controller to report
on the state of the carbon and sediment filters. The addition of a pressure sensor also
allows the controller to shut down the pump in the event of mains water failure.
Fitting
The S3 is supplied already wired. There is no need to disconnect any wires. Follow these
instructions carefully and refer to the system diagram.
IT IS RECOMMENDED THAT THE S3 IS FITTED AGAINST A WALL OR SIMILAR VERTICAL
SURFACE.
1. Ensure the S3 is NOT PLUGGED INTO THE MAINS SUPLLY.
2. Remove the top cover by loosening the four corner screws. Remove top cover by
folding to the right.
3. Screw unit to the wall or vertical surface through the four ready drilled holes in the
back box corners.
5. Carefully replace the top cover and tighten the four corner screw.
Specification
Mains Supply Voltage
Pump Voltage
Fuse Rating
Maximum Pump Power
Enclosure Material
Water Resistance
Dimensions
Working Temperature
90 - 260 Vac
90 - 260 Vac
5A Quick Blow
1000VA
ABS
IP65
240 x 160 x 90 (mm)
0 to 40 Deg C
Value
DISCLAIMER
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES TO ANY PRODUCT HEREIN TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN. THE MANUFACTURER DOES NOT ASSUME ANY LIABILITY ARISING
OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
For more information and videos on how to use Spring controllers please visit: www.springltd.co/videos
Set up the system carefully. Follow these instructions very closely, paying close
attention to all warnings and diagrams.
The S3 is fused at 5A. Always fit the correct 5A quick blow mains fuse. The S3 can
control pumps up to 1000VA (1000W). DO NOT USE THE S3 WITH PUMPS GREATER
THAN 1000VA.
The S3 and pump mains socket are supplied in a waterproof enclosure. The mains
plug is NOT WATERPROOF. Do not plug the mains plug into a socket that could
become wet during operation, failure to do so will result in damage to the unit.
Ensure the 230Vac pump mains socket enclosure is closed tightly before turning the
controller on. This will prevent the connection getting splashed or wet during use,
failure to do so will result in damage to the unit.
Filling & Fitting
THE UNIT MUST BE INSTALLED BY A COMPETENT ELECTRICIAN OR ELECTRICAL
ENGINEER. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD INVALIDATE
THE CONTROLLER WARRANTY.
ALWAYS DISCONNECT THE MAINS SUPPLY BEFORE OPENING UNIT.
ALWAYS DISCONNECT THE MAINS SUPPLY BEFORE CONNECTED THE PUMP.

S3 Controller
FILL
WATER
IN
CARBON +
SEDIMENT
FILTERS
WASTE
WASTE
RO
FILTER
DI
VESSEL WATER TANK
230Vac
BOOSTER
PUMP
RO INLET
SOLENOID
VALVE
FLOW
METER
PRESSURE
SENSOR
AUTOFLUSH
VALVE
MANUAL FLOW
RESTRICTOR
VALVE
TDS RO TDS DI
HIGH LEVEL
SWITCH
AUTOFILL CONTROL
TDS DI
YELLOW
YELLOW
TDS RO
AUTOFLUSH
SOLENOID 2
PRESSURE
SENSOR
FLOW METER
FILL
SOLENOID 1
WHITE
WHITE
PLUGABLE
CONNECTOR
PLUGABLE
CONNECTOR
GREY
GREY
S3 Pump Controller
Overview
F
230Vac
PUMP
MAINS
SOCKET
P
F
230Vac
PUMP
MAINS
SOCKET

Quick Start Guide S3
Filling - Wiring
Fill - Autoflush
System System
Filling
Connect the pump controller following this diagram. Use only wire from the middle
gland. NOTE: only fit the fuse once all connections are made.
To start filling the tank simply press the ‘F’ (Fill) button briefly. This will activate the RO
inlet solenoid valve, allowing water to fill the tank, until the float switch detects that the
tank is full.
When fill is started the system will open the
Autoflush valve for 5 mins (in every hour) to
clean RO.
The Autoflush valve will then close when
flushing has finished and controller will
continue to fill via the RO inlet valve.
After flushing the booster pump will turn
on if ‘boost on flush’ is ‘off’.
System
Full
When the tank water level rises sufficiently
to activate the level switch, filling is stopped.
All valves are closed.
To manually stop the tank filling, (if ‘On
Demand’ is ‘Off’) press the ‘F’ (Fill) button
again breifly. The display will remove the
‘Fill’ message.
NOTE 1: The solenoid valve will be turned off if the unit detects a loss of mains
water pressure (below 10 PSI).
RO Inlet (Fill) Valve Autoflush Valve High Level Switch
Grey White
F
F
TDS Wiring S3
For the TDS probes in John Guest 1/2” equal tee pieces (not supplied) as shown on
the diagram.
We recommend RO TDS probe to be fitted after the RO (reverse osmosis) filter. You can
then check the RO is working correctly. If you see these values rising over time it could
indicate a problem with the RO.
We recommend DI TDS probe be fitted after the DI (de-ionising) vessels. You can then
check DI vessels are working (and that the resin is not depleted).
For good cleaning a TDS value below 5ppm after the DI is recommended.
The TDS function provides an indication of the water purity. The TDS values displayed
are in ppm (parts per million). The TDS meter has a max reading of 50ppm.
To monitor the current TDS reading press enter repeatedly until it displays the TDS screen.
TDS RO 30
TDS DI 1
Install on
RO outlet
Install on
DI outlet
RO TDS
Probe
DI TDS
Probe
Take care when handling TDS probes. Do not damage gold plated contacts
as this will affect TDS accuracy.
Ensure gold plated contacts are clean before use. Clean with ISOPROPANOL
alcohol (IPA) and a soft cloth.
Dirty contacts will affect TDS accuracy, clean with IPA if readings appear to
deviate over time.
F
F
230Vac
PUMP
MAINS
SOCKET
230Vac
PUMP
MAINS
SOCKET
230Vac
PUMP
MAINS
SOCKET

Pressure Thresh
Enter to set
Pressure Thresh
30 PSI
Press the down and enter buttons to access
the controller settings menu. ‘Pressure
Threshold’ will be displayed. Press enter to
change this item.
Use up or down button to change. ‘Off’
disables pressure sensor warnings. ‘Cal’
calibrates for a new filter, press enter to
start calibration. ‘Cal’ must be set at time of
insallation of new filter to provide accurate
carbon filter warnings.Press enter again to
go back to the settings menu
Tot Flow Thresh
Enter to set
Press up to display the next settings menu
item, ‘Total Flow Threshold’. This sets the
water life warning for the RO Press enter
to set this value e.g. 600KL
Use up or down button to set the total
water use which will give a warning when
reached. Press enter again to go back to
the settings menu.
Tot Flow Thresh
600KL
TDS RO Limit
Enter to set
Press up to display the next settings menu
item, ‘TDS RO Limit’. TDS readings over this
value from the RO will display a warning and
if shutdown enabled stop the fill. Press enter
to change this value.
TDS RO Limit
30
,
Use the up or down button to set. ‘Off’
disables TDS control. Set from 1-50 TDS.
Press enter to go back to the settings menu.
+
,
,
,
,
,
,
TDS DI Limit
Enter to set
TDS DI Limit
5
Press up to display the next settings menu
item, ‘TDS DI Limit’. TDS readings over this
value from the DI will display a warning and
if shutdown enabled stop the fill. Press enter
to change this value.
Use the up or down button to set. ‘Off’
disables TDS control. Set from 1-10 TDS.
Press enter to go back to the settings menu.
PRESS AND HOLD ENTER TO EXIT SETTINGS MENU.
Note: you can adjust this value manually
with the up or down button.
TDS RO Shutdown
Enter to set
Press up to display the next settings menu
item, ‘TDS RO Shutdown’. ‘On’ will stop the fill
if the TDS level is above the limit value. ‘Off’
disables this function. Press enter to change
this setting.
TDS RO Shutdown
On
Use the up or down button to chnage
between on or off. Press enter to go back
to the settings menu.
,
,
TDS DI Shutdown
Enter to set
Press up to display the next settings menu
item, ‘TDS DI Shutdown’. ‘On’ will stop the fill
if the TDS level is above the limit value. ‘Off’
disables this function. Press enter to change
this setting.
TDS DI Shutdown
On
Use the up or down button to chnage
between on or off. Press enter to go back
to the settings menu.
,
,
Set Up S3
Controller Settings
S3 Pump Controller
Set Up Controller Settings
,
Boost on flush
Enter to set
Boost on flush
On
Press up/down to scroll through the settings
menu until you reach the menu item ‘Boost
on flush’ press enter to change the Booster
pump socket setting.
Use the up/down button to change. ‘On’
Enables the booster pump when system is
autoflushing. ‘Off’ Disables the booster
pump when system is autoflushing.
,
Fill on demand
Enter to Set
Press up to display the next settings menu
item, ‘Fill on demand’. Press enter to change
this value.
Fill on demand
On
Use the up or down button to set. ‘On’
will set to Fill on demand (refills every
time the level switch drops). ‘Off’ will set
to One time fill (stops when the level
switch activates/lifts).
Press enter to go back to the settings menu.
,
,

TDS RO 30
TDS DI 1
Press enter to display current TDS values
after the RO and after the DI.
Press enter again to display:
Total water used since last pre-filter change
and zeroing of counter.
Overall amount of water used since install.
Total 12.3kl
Overall 200.5kl
Pressure 44psi
Temperature 18c
Press enter again to display:
Pressure of mains water in PSI.
Temperature of water to hose (degrees C)
WARNING
Water Discnnectd
This message during a fill suggests that the
mains water has been disconnected.
WARNING
Pressure Error
This message indicates that the pressure
sensor has been disconnected or has
failed.
The pressure has dropped below the value
set in Pressure Threshold, indicating a
blocked carbon or sediment filter.
WARNING
Carbon Filter
WARNING
Chk RO Membrane
This message is displayed when the amount of
water that has flowed goes over the Total Flow
Threshold. Check the RO membrane.
TDS RO 30
TDS DI 1
Press enter again to return to TDS values.
The S3 has a number of warning messages for when something goes wrong in the
system, these are designed to help with trouble shotting.
F
Start / Stop Filling Increase a value
or go up to next
menu item
Decrease a value
or go down to
next menu item
Enter / Set a
value or scroll to
next display item
Operation S3 Warning Messages S3
Flow 2.4l/m
Press enter again to display:
Flow in litres per minute.
This message is displayed when the
system is flushing.
System
Fill- Autoflush
System
Ignoring TDS
This message is displayed when the system is
flushing and shortly after the system has
completed flushing.
This message is displayed when the
system is full.
System
Full
System
Filling
This message is displayed when the system is
filling.
This message is displayed when the system
is paused by the TDS exceeding the limit
and the TDS Shutdown is ‘On’.
System
Filling paused
WARNING
High RO TDS
This message is displayed when the the TDS
exceeds the set limit.
WARNING
High DI TDS
Table of contents
Other Spring Controllers manuals
Popular Controllers manuals by other brands

Montalvo
Montalvo Z4 Technical manual

Siemens
Siemens Flowrite 599 Series Technical instructions

Norac
Norac UC4+ Hardi OEM installation manual

elsner elektronik
elsner elektronik KNX S1R-B4 compact Installation and adjustment

FlowCon
FlowCon SM Series Installation and operation instruction

SKF
SKF Ecomag Installation, operation and maintenance

Eaton
Eaton EPCT Fire Series installation manual

United Process Controls
United Process Controls PROTHERM 50 operating manual

Matelec
Matelec FPC-15205 Owner's operation manual

Axxeron
Axxeron HESCH HE 5710 operating instructions

COPES-VULCAN
COPES-VULCAN 700 instruction manual

3M
3M EX II 3000SP reference guide