Adjust the flow settings carefully. Repeated false dead-end detection
indicates that the Cal value should be increased (less sensitive).
For safety wire through the pump pressure switch. (The pressure
switch can be bypassed if absolutely necessary - the unit will protect
itself under normal conditions.)
This is a WATER PUMP controller: it will not work with air in the system.
Always prime the system before starting work. If air in the system
causes false dead-end detection, increase Cal value until air is removed.
Do not set the Cal value too high. Setting it higher than necessary
places extra strain on both the pump and the controller in a dead
end situation. This can result in damage to both the pump and
your controller.
* Your battery is at risk of permanent damage if you disable low battery cutoff and continue
to use your controller for long periods when the battery voltage has fallen below +10.5V.
Operating Warnings
DISCLAIMER
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES TO ANY PRODUCT HEREIN TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN. THE MANUFACTURER DOES NOT ASSUME ANY LIABILITY ARISING
OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
For more information and videos on how to use Spring controllers please visit: www.springltd.co/videos
Copyright © 2021 Spring (Europe) Ltd. All rights reserved. PATENT PENDING 1918133.8
Specification
Supply Voltage
Maximum Current
Typical Drive Current
Voltmeter Accuracy
Enclosure Material
Water Resistance
Dimensions
Working Temperature
11 - 15 VDC
35A
15A
+- 100mV
Polycarbonate
IP65
115 x 90 x 55 (mm)
0 to 40 Deg C