manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Spring
  6. •
  7. Controllers
  8. •
  9. Spring V11 DUAL User manual

Spring V11 DUAL User manual

Other Spring Controllers manuals

Spring V11M User manual

Spring

Spring V11M User manual

Spring V11 Hot Water Instruction Manual

Spring

Spring V11 Hot Water Instruction Manual

Spring V11 User manual

Spring

Spring V11 User manual

Spring V16 HC RW User manual

Spring

Spring V16 HC RW User manual

Spring S3 User manual

Spring

Spring S3 User manual

Spring V11M BPC User manual

Spring

Spring V11M BPC User manual

Spring V16 HC User guide

Spring

Spring V16 HC User guide

Spring V16M BPC FL User manual

Spring

Spring V16M BPC FL User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Pump 2
Operating Warnings Pump Controller - Quick Start Guide V11 DUAL
Adjust your flow settings carefully. Repeated false dead-end detection
indicates that the Cal value should be increased (less sensitive).
For absolute safety always wire through the pump pressure switch.
(The pressure switch can be bypassed if absolutely necessary - the
unit will protect itself under normal conditions.)
This is a WATER PUMP controller: it will not work with air in the system.
Always prime your system before starting work. If air in the system
causes false dead-end detection, increase Cal value (less sensitive).
Do not set the Cal value too high. Setting it higher than necessary
places extra strain on both the pump and the controller in a dead
end situation. This can result in damage to both the pump and
your controller.
Specification
Supply Voltage
Maximum Current
Typical Drive Current
Voltmeter Accuracy
Enclosure Material
Water Resistance
Dimensions
Working Temperature
11 - 15 VDC
15A
7-9A
+- 100mV
ABS
IP65
195 x 80 x 55 (mm)
0 to 40 Deg C
Value
DISCLAIMER
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES TO ANY PRODUCT HEREIN TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN. THE MANUFACTURER DOES NOT ASSUME ANY LIABILITY ARISING
OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
Make sure correct fuse is fitted inline. Failure to do so will result in damage to the unit.
Observe correct battery polarity. Failure to do so will result in damage to the unit.
* Your battery is at risk of permanent damage if you disable low battery cutoff and continue
to use your controller for long periods when the battery voltage has fallen below +10.5V.
Fuse 15A
+
12V
Pump 1
Battery
1 12 2
Step 1
Connect the pump controller in accordance with this diagram. NOTE:
only fit the fuse once all connections are made.
V11 DUAL Wiring
For more information and videos on how to use Spring controllers please visit: www.springltd.co/videos
Step 2 Step 3 Operation
Set up - Auto Calibrate V11 DUAL V11 DUAL
Connect your hose and brush to the pump.
Turn on the controller by pressing the up or down button.
Keep the button held until the display lights up.
Press up until the display shows 30.
Press and hold the up and enter buttons to calibrate. CAL will be displayed.
Press the down button to select Auto Cal, AUt will be displayed. Press the
enter button to start. Auto Cal starts from C99.
After several moments the calculated CAL value (e.g. C50) will be displayed
and the controller is ready to use. Press enter to exit calibration.
The CAL value can be adjusted manually by following the same steps and
adjusting the CAL value by pressing the up or down button instead of using AUt.
To enable or disable the low battery cut-off (that stops your pump when
the battery voltage is below 10.5V) press and hold the down and enter
buttons on PUMP 1.
Then use the up or down button to select ON or OFF. Press enter to save.
NOTE: ‘ON’ keeps your battery protected.
Press up or down to set a suitable flow of water.
Press enter (PUMP 1 only) to display the current battery voltage.
Press enter again to return to the current flow rate.
To turn the controller off, press and hold enter.
+
+
,
,
,
Message
An error has occured while using AutoCal. This will
happen when the motor is not connected or the
enter button has been pressed to cancel it.
Pressure switch has activated or the motor is
disconnected.
A dead end has been detected. If this is not the case, try
increasing the calibration value.
This message will start to flash when the battery is low
(<11.0V). If the battery is below 10.5V the pump will be
disabled to protect the battery (unless low battery cutoff
is disabled*).
Description