Assembly/operating instructions for SSC-LUXon wall light NORSU with motion detector
1. Intended use
This product is for lighting purposes only and:
- can be installed indoors and outdoors / protection type IP65, suitable for use in damp areas,
- must not be exposed to strong mechanical loads or heavy soiling,
- may not be operated after damp or dirty storage until after a condition check,
- may not be changed or modied, otherwise the operating permit and conformity will expire with immediate eect!
It is not allowed to remove the type plate.
 If the aforementioned points are not observed, a short circuit or electric shock may occur! There is danger to life!
2.General safety instructions
The complete installation may only be carried out by an authorized electrician who is familiar with the applicable guidelines. Hereinafter
referred to as „qualied electrician“.
For safe handling of the product, the user must have read and understood the installation/operating instructions completely before using
the device for the rst time.
 The product may only be used if it is alright. If the device or parts of it are defective, it must be repaired by a qualied electrician.
This product is not a toy and is not allowed be stored or used within the reach of children.
 Safe operation of the product is only guaranteed if these instructions are followed. Therefore, keep these assembly/operating instructions.
SSC-LUXon GmbH accepts no liability if the instructions given here are not followed or the lamp is subjected to improper use.
3. Assembly & conguration
Caution: The connecting cable must be disconnected from the power supply before starting work (switch o the main switch/fuse)! Only use
parts which are supplied with the product or which are clearly marked as equipment! Otherwise the product may not be suciently safe!
When drilling, pay attention to cables and gas and water lines.
3.1 Assembly location
The product may only be mounted on a stable, tilt-resistant and level surface. Do not cover the product under any circumstances, especially
not with insulating material!
4. Operation, faults & disorders
 Caution: Disconnect the connection cable from the power supply before starting work!
Never look directly into the light source!
What to do in case of error?
In case of an error, the device must be switched o immediately. The product may only be operated if it works correctly. The device may only
be put back into operation after it has been checked by a qualied electrician! This is the case if:
1. there is visible damage, 2. the product is not working corrctly, 3. there is smoke, steam, or audible crackling noises, 4. overheating can be
detected.
Caution: There is a danger to life! Repairs to the product or work on parts carrying mains voltage may only be carried out by qualied
electricians.
Avoidance of disturbances and re hazards:
It is not allowed to cover the product under any circumstances. Air circulation must be ensured. Nothing may be attached or hung on the
product, especially no decoration.
5. Cleaning & care instructions
The product may only be wiped dry or carefully with a slightly damp and lint-free cloth. The product is not allowed to be removed for this
purpose. Do not use abrasive or sharp objects or aggressive cleaning agents. Do not use solvents.
Technical data NORSU
Models: NORSU - 990010017 (1-ame) - 990010018 (2-ame)
Type: Wall light with motion detector PIR swivelling
Voltage: 220-240 V AC / 50-60 Hz
Protection type: IP65
Max. angle of coverage: 240°
Material: Aluminium & plastic
Operating temperature: -5°C - +45° C
Max. power: 990010017 - 30 W / 990010018 - 40 W
Protection class: I
Can be used
indoors and
outdoors
Notes / explanations & legend
Important information
Protection class I
Installation only by qualied
electrician
Disconnect the device from the
mains power before starting
any work
SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen, Germany
E-Mail: [email protected]; Phone: +49 7633 - 988 3000
SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen, Germany
E-Mail: [email protected]; Phone: +49 7633 - 988 3000
Vers. 04/2023
NORSU
Rotatable/swivelling: Yes
Colour: Black
Surface: Textured coated
Max. detection range: 10 m
Optimal installation height: 180 - 250 cm
Adjustable light duration: 10 sec. to 15 min.
Disposal instructions
Make sure to dispose packaging in accordan-
ce with the applicable guidelines of your local
authority. Devices marked with the crossed-
out waste garbage do not belong in the
household waste! You are obliged to hand
in these devices at one of the free collection
points in your municipality. You can obtain
more information from your local authority,
the relevant town hall or a local or regional
waste disposal company.
Keep packaging material and small parts
away from children and animals. Danger of
suocation!
Notes on use indoors & outdoors
Protection type IP2X: Use only indoors
and dry, i.e. do not use in damp or dirty
rooms and in areas of high humidity
Protection type IP4X, IP5X & IP6X: Can be
used indoors and outdoors
Onlineshop:
www.led-lichtraum.de
Satised with your product?
Then we look forward to your
product review in our online store,
on Amazon or eBay!
SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen, Germany
E-Mail: [email protected]; Phone: +49 7633 - 988 3000
1. Disconnect the connecting cable from the power supply!
2. Loosen screws (2x) on the side & remove plastic cover.
3. Mark out the drill holes with the help of the back plate or measure (see markings on the back
plate - 60 / 20 mm) and drill the holes. Insert the dowels into the drill holes. Guide the connection
cable through the round rubber seal (pierce).
4. Screw the back plate to the wall. The screws are screwed directly through the seals.
5. Connect the connecting cables (L, N and, if necessary, earth) to the light. The designations pro-
tective conductor, N & L are also printed on the luster terminal. Do not use the L' input for the main
connection - this is used as an output to couple other lights with the motion detector.
6. Place the light on the back plate on the wall. Screw the light back in place with the screws from
step 2.
7. Switch the connection cable to voltage, the product is now ready for use.
Assembly instructions
 Corner mounting: The light can be installed not only directly on the wall but also in the outer
corner with the help of the adapter. To do this, screw the corner adapter into the desired position.
The back plate is then screwed directly onto the adapter instead of onto the wall. The further instal-
lation steps are then identical.
Setting the range and brightness
1. Turn the Time knob (Time) counterclockwise to the minimum (10s). Turn the LUX (light sensitivity) knob clockwise at the maximum (sun). With this position of "LUX", the light also works in
daylight, so perfect for a rst test of the function.
2. If not already done, switch on the power; After a short warm-up time, the sensor can start working. When the sensor receives a signal, the lamp turns on. As long as there is no further
signal, the load should stop working within 10s±3s and the lamp switches o.
3. Now set the desired time with the Time button, the brightness with the Sens button and the light sensitivity with the LUX button. To nd out the desired light sensitivity, it is advisable to
set this at dusk or at night.
Tip: If you are testing in daylight, please turn the LUX knob to the (sun) position, otherwise you will not be able to test the light in daylight!
Norsu
Further light Further light
Solutions to problems
The light does not work:
1. Please check whether all cables have been connected correctly and whether the main switch (fuse box) has
been switched on.
2. Please check that the light is correctly connected to the power cable and that it is generally fully functional.
3. Please check whether the sensitivity (LUX) settings may be set too low.
The motion detector does not switch correctly:
1. Please check if there is an obstacle in front of the motion detector that does not allow the signals to be received.
2. Please check if the ambient temperature (-20° to +45°) is too high.
3. Please check if the movement is within the maximum detection range (10 metres).
4. Please check that the mounting height corresponds to the height described in the technical data.
5. Please check that the motion detector has been set (rotated) so that it is aligned with the area to be detected.
The light does not switch o automatically:
1. Please check if there is a continuous signal in the detection eld e.g. trees moving due to wind etc.
2. Please check if the time has been set to the maximum position, in this case the time is set to 15 min.
Adjusting the aperture on the sensor
With the aperture directly on the sensor, you can adjust the detection
range very precisely. To do this, simply turn the aperture so that the
area to be captured is in the "free" area of the aperture. Only move-
ments that occur in this area are detected.
Tip:
You can also enlarge the area. To do this, pull the bezel down and
enlarge the area with a sharp knife or scissors.
Set the detection range to 240°:
To use the entire detection range of 240°, simply pull o the cover
completely and use the NORSU wall luminaire without it. In this case,
you have the largest possible detection angle. If this is too large, simply
put the cover back on the light.

This manual suits for next models

2

Other SSC-LUXon Lighting Equipment manuals

SSC-LUXon ClickConnect Basic Quick reference guide

SSC-LUXon

SSC-LUXon ClickConnect Basic Quick reference guide

SSC-LUXon TWEO Quick reference guide

SSC-LUXon

SSC-LUXon TWEO Quick reference guide

SSC-LUXon ATUNI Quick reference guide

SSC-LUXon

SSC-LUXon ATUNI Quick reference guide

Popular Lighting Equipment manuals by other brands

BARRON Trace-Lite AXL2 installation instructions

BARRON

BARRON Trace-Lite AXL2 installation instructions

Lightolier EG2-12 Specification sheet

Lightolier

Lightolier EG2-12 Specification sheet

Exit Light NYCLSM Series installation instructions

Exit Light

Exit Light NYCLSM Series installation instructions

IEK 5050 BASIC INFORMATION

IEK

IEK 5050 BASIC INFORMATION

Chauvet Professional onAir IP panel min user manual

Chauvet Professional

Chauvet Professional onAir IP panel min user manual

LEGRAND LED SATELLITE Installation instruction sheet

LEGRAND

LEGRAND LED SATELLITE Installation instruction sheet

FLEXSTAR 120W DIMMABLE instruction manual

FLEXSTAR

FLEXSTAR 120W DIMMABLE instruction manual

LumX HS-1000 instruction manual

LumX

LumX HS-1000 instruction manual

Whelen Engineering Company ECE Cenator HC Series installation guide

Whelen Engineering Company

Whelen Engineering Company ECE Cenator HC Series installation guide

NETO M-PANEL user manual

NETO

NETO M-PANEL user manual

Beamever LINIO NEON 1220 SV BLACK installation instructions

Beamever

Beamever LINIO NEON 1220 SV BLACK installation instructions

Ikan ID508-v2 quick start guide

Ikan

Ikan ID508-v2 quick start guide

Stahl TRANBERG IMT ILED CIRCLE-H 2.0 installation manual

Stahl

Stahl TRANBERG IMT ILED CIRCLE-H 2.0 installation manual

STMicroelectronics STCF03 manual

STMicroelectronics

STMicroelectronics STCF03 manual

Artecta Aviano 10 CCT V1 user manual

Artecta

Artecta Aviano 10 CCT V1 user manual

Chalmit Protecta III 02L Installation, operation and maintenance instructions

Chalmit

Chalmit Protecta III 02L Installation, operation and maintenance instructions

Brilliance BriLux DMX Power Washer manual

Brilliance

Brilliance BriLux DMX Power Washer manual

Life 39.9PF2023C quick start guide

Life

Life 39.9PF2023C quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.