Thermometer
MODEL: 620011
INSTRUCTION MANUAL
Stalgast sp. z o.o. ul. Staniewicka 5 03-310 Warszawa
CHARACTERISTICS OF THE DEVICE1.
Broad scope of measurement•
Rotating probe•
Low battery use•
Stainless steel probe•
Pocket size•
Max/min temperature memory•
Hold reading function•
Possibility to display measurement in two different scales: Celsius and Fahrenheit•
TECHNICAL SPECIFICATION2.
Range of measurement -50 ~ 300 ° C/- 58 ~ 572°F
Accuracy of the display ±2° C between –50 ~ -20°C / ±3.6° F between –58 ~ -4°F
±1° C between –20 ~ 150°C / ±1.8° F between -4oF ~ 302oF
±3° C between 150 ~ 250°C / ±5.4° F between 302° F ~ 482°F
±4° C between 250 ~ 300° C / ±7.2° F between 482° F ~ 572°F
Minimum read on the display 0.1° within range
Alarm setting accuracy 1° within range
Update frequency of the temperature reading 1 Second
Temperature unit °C or °F factory settings
Automatic disabling of the device After 10 minutes of inactivity
The display size 28 (W) x 16 (H) mm
Battery 1.5 Volt, type AAA (sold without batteries)
Battery Life Ca. 8,000 hours continuous work
The probe dimensions 3.5 (Ø) x 1 5 (length) mm
Dimensions of the device 52 (W) x 160 (H) mm
Working temperature 0 ~ 50 °C / 32 ~ 122 °F
INSTALLATION3.
Open the battery container1.
Install battery, mind the polarity (+/-)2.
Close the battery container lid.3.
OPERATING THE DEVICE4.
MEASUREMENT4.1.
Pull the probe and turn it clockwise to set it at the desired angle1.
Place the probe in the product intended for measurement, insert it to a depth of 25mm (1”) and read the temperature.2.
UNIT OF TEMPERATURE MEASUREMENT4.2.
Press and hold the [°C/°F] button for about 3 seconds, then release the button and choose the unit of measurement