Starwin FL30F-M User manual

1
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Starwin
uSat Fixed (Manual) Terminal User Manual
Name: Flat Panel Integrated Satellite Communication Terminal
Model Number: FL30F-M
FL30F-M uSat Flat Terminal
Make Satellite Simple & Easy
Make Antenna of the future

2
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Legal Rights
© Copyright 2013 China Starwin Science & Technology Co., Ltd. All rights reserved.
The material contained herein is proprietary, privileged, confidential and owned by China
Starwin or its third party licensors. No disclosure thereof shall be made
to third parties without the express written permission of China Starwin Science & Technology
Co., Ltd.
China Starwin Science & Technology Co., Ltd. reserves the right to alter the equipment
specifications and descriptions in this publication without prior notice. No part of this
publication shall be deemed to be part of any contract or warranty unless specifically
incorporated by reference into such contract or warranty.
Statement of Conditions
The information contained in this manual is subject to change without prior notice.
China Starwin Science & Technology Co., Ltd. shall not be liable for errors contained herein or
for incidental or consequential damages in connection with the furnishing, performance, or use
of this manual or equipment supplied with it.
Warranties and Disclaimers
All China Starwin Science & Technology Co., Ltd. (“China Starwin”) products purchased from
China Starwin or through any of its authorized by China Starwin distributors, resellers and
agents are subject to the following warranty and product liability terms and conditions.
Exclusive Warranty
China Starwin warrants that the Product hardware it supplies and the tangible media on which
any software is installed, under normal use and conditions, will be free from significant defects
in materials and workmanship for a period of twelve (12) months from the date of delivery of a
given Product to Purchaser (the "Warranty Period"). China Starwin will, at its sole option and as
Purchaser's sole remedy, repair or replace any defective Product in accordance with China
Starwin standard R&R procedure.
CHINA STARWIN SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING
AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT
DOES NOT EXIST OR WAS CAUSED BY PURCHASER'S OR ANY THIRD
PERSON'S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR IMPROPER
TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE
BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,
LIGHTNING OR OTHER HAZARD.

3
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Disclaimer
(a) THE PRODUCT IS SOLD ON AN "AS IS" BASIS. CHINA STARWIN, ITS AFFILIATES
OR ITS LICENSORS MAKE NO WARRANTIES, WHATSOEVER, WHETHER EXPRESS
OR IMPLIED, WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING
DOCUMENTATION. CHINA STARWIN SPECIFICALLY DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
AND NON-INFRINGEMENT WITH RESPECT TO THE SOFTWARE. UNITS OF PRODUCT
(INCLUDING ALL THE SOFTWARE) DELIVERED TO PURCHASER HEREUNDER ARE
NOT FAULT-TOLERANT AND ARE NOT DESIGNED, MANUFACTURED OR INTENDED
FOR USE OR RESALE IN
APPLICATIONS WHERE THE FAILURE, MALFUNCTION OR INACCURACY OF
PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE
PHYSICAL OR ENVIRONMENTAL DAMAGE ("HIGH RISK ACTIVITIES"). HIGH
RISK ACTIVITIES MAY INCLUDE, BUT ARE NOT LIMITED TO, USE AS PART OF
ON-LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING
FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR
FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR
TRAFFIC CONTROL, LIFE SUPPORT MACHINES, WEAPONS SYSTEMS OR
OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL
HAZARD. CHINA STARWIN SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES.
(b) PURCHASER'S SOLE REMEDY FOR BREACH OF THE EXPRESS WARRANTIES
ABOVE SHALL BE REPLACEMENT OR REFUND OF THE PURCHASE PRICE AS
SPECIFIED ABOVE, AT CHINA STARWIN’S OPTION. TO THE FULLEST EXTENT
ALLOWED BY LAW, THE WARRANTIES AND REMEDIES SET FORTH IN THIS
AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR
CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW,
STATUTORY OR OTHERWISE, INCLUDING BUT NOT LIMITED TO WARRANTIES,
TERMS OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION,
NON-INFRINGEMENT, AND ACCURACY OF INFORMATION GENERATED. ALL OF
WHICH ARE EXPRESSLY DISCLAIMED. CHINA STARWIN’ WARRANTIES HEREIN
RUN ONLY TO PURCHASER, AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
CHINA STARWIN NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO
ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE,
INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS.
Limitation of Liability
(a) CHINA STARWIN SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD
PARTY, FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF
BUSINESS OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR

4
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER ARISING UNDER
BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY
OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR
OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
(b) TO THE EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL
THE LIABILITY FOR DAMAGES HEREUNDER OF CHINA STARWIN OR ITS
EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT
BY PURCHASER, NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL
PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID FOR
THAT PRODUCT BY THAT PARTY (EXCEPT IN THE CASE OF A BREACH OF A
PARTY'S CONFIDENTIALITY OBLIGATIONS).
Electronic Emission Notices
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Safety Considerations
For the following safety considerations, "Instrument" means the ‘uSat Flat Terminal’ units,
components and their cables.
It is necessary to read the instructions carefully before using the uSat flat portable terminal. The
terminal usage shall be carried out in accordance with the described steps and methods to ensure
the safety and accuracy of equipment operation.
Radio
The instrument transmits radio energy during normal operation. To avoid possible harmful
exposure, to this energy, do not stand or work for extended periods of time in front of its antenna.
The long-term characteristics or the possible physiological effects of Radio Frequency
Electromagnetic fields have not been yet fully investigated.
Caution
1. To avoid electrical shock, do not perform any servicing unless you are qualified to do so.
2. Before connecting this instrument to a power source, make sure that the voltage of the
power source matches the requirements of the instrument.

5
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Disposal of Electronic and Electrical Waste
Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with
unsorted waste. Please contact your local recycling authority for disposal of this product.
Important Notice
This user manual is delivered subject to the following conditions and restrictions:
▪This manual contains proprietary information belonging to China Starwin Science &
Technology Co., Ltd. Such information is supplied solely for the purpose of assisting
properly authorized users of the respective China Starwin products.
▪No part of its contents may be used for any other purpose, disclosed to any person or firm
or reproduced by any means, electronic and mechanical, without the express prior written
permission of China Starwin Science & Technology Co., Ltd.
▪The text and graphics are for the purpose of illustration and reference only. The
specifications on which they are based are subject to change, without prior notice.
▪The software described in this document is furnished under a license. The software may be
used or copied only in accordance with the terms of that license.
▪Information in this document is subject to change without prior notice.
▪Corporate and individual names and data used in examples herein are fictitious, unless
otherwise noted.
▪China Starwin Science & Technology Co., Ltd. reserves the right to alter the equipment
specifications and descriptions in this publication without prior notice. No part of this
publication shall be deemed to be part of any contract or warranty unless specifically
incorporated by reference into such contract or warranty.
▪The information contained herein is merely descriptive in nature and does not constitute an
offer for the sale of the product described herein.
▪Any changes or modifications of the equipment, including opening of the equipment when
not expressly approved by China Starwin Science & Technology Co., Ltd., will void
equipment warranty and any repair thereafter shall be liable to a charge. It may also void
the user's authority to operate the equipment.
Some of the equipment provided by China Starwin and specified in this manual, is manufactured
and warranted by third parties. All such equipment must be installed and handled in full
compliance with the instructions provided by such manufacturers as attached to this manual or

6
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
provided thereafter by China Starwin or the manufacturers. Non compliance with such
instructions may result in serious damage and/or bodily harm and/or void the user's authority to
operate the equipment and/or revoke the warranty provided by such manufacturer.
Instructions
The uSat Terminal is a full satellite earth station system for communication in Ku-band. The
satellite parameters shall be selected only according to the specific user conditions required.
The China Starwin uSat Terminal User Manual provides operational instructions, for the device,
which are standard for applications in Ku-band. However, the specific modem and antenna
electrical performance parameters need to be taken in account. This manual is intended for
technicians responsible for the installing, setting up and operating of the uSat Terminal and for
system administrators who are responsible for managing the system.

7
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Safety Alert Messages
Safety alert messages call attention to potential safety hazards and tell you how to avoid them.
These messages are identified by the signal words DANGER, WARNING, or NOTICE, as
illustrated below. To avoid possible property damage, personal injury, or in some cases possible
death, read and comply with all safety alert messages.
DANGER: Indicates a potentially hazardous situation which, if not avoided, will result in death or
serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in minor
or moderate injury.
NOTICE: It is used for advisory messages concerning possible property damage, product damage
or malfunction, data loss, or other unwanted results – but not personal injury.
Indicates a safety message that concerns a potentially hazardous situation in which you could fall.
Indicates a safety message that concerns a potential electric shock hazard.

8
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Contents
1 INTRODUCING THE USAT FLAT-PANEL FL30F-M FIXED TERMINAL ..................................................... 1
2 TECHNICAL SPECIFICATION........................................................................................................................... 2
3PACKING LIST ................................................................................................................................................ 4
3.1 UNPACKING AND INSPECTION ....................................................................................................................................4
3.2 FREIGHT DAMAGE ..................................................................................................................................................... 4
3.3 MATERIAL-MISSING OR DAMAGED ...........................................................................................................................4
3.4 BASIC EXTERNAL CONFIGURATION OF USAT TERMINAL............................................................................................5
4DESCRIPTION OF FIXED TERMINAL ........................................................................................................ 6
4.1 TERMINAL STRUCTURE DIAGRAM .............................................................................................................................6
4.2 TERMINAL INSTALLATION METHODS ..................................................................................................................7
4.3 TERMINAL WIRELESS ACCESS DETAILS.....................................................................................................................9
5TERMINAL INSTALLATION, INITIALIZATION AND ALIGNMENT......................................................10
5.1 TERMINAL INSTALLATION........................................................................................................................................10
5.2 TERMINAL INITIALIZATION ...................................................................................................................................... 12
5.2 TERMINAL ALIGNMENT ...........................................................................................................................................16
6MODEM STATUS INDICATION ...................................................................................................................22
7APPLICATION (‘APP’) FOR TERMINAL CONTROL ................................................................................23
8TROUBLESHOOTING AND MAINTENANCE ............................................................................................29
9.1 TROUBLESHOOTING.................................................................................................................................................29
9.2 MAINTENANCE ........................................................................................................................................................29
9TECHNICAL SERVICE CONTACT INFORMATION .................................................................................30
10 PRODUCTION SPEC......................................................................................................................................30

1
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
1 Introducing the uSat Flat-Panel FL30F-M Fixed Terminal
FL30F-M series integrated satellite communication terminal has completely changed the standard parabolic form
used for satellite communication for a long time, and is the real next generation of satellite communication
terminal. Fl30F-M integrated satellite broadband portable terminal adopts advanced high gain horn waveguide
array antenna and integrates necessary components of satellite communication: Antenna system, RF unit, Servo
system, Satellite modem, Wireless router and Power supply system, which makes FL30F-M completely separated
from the traditional Parabolic form, with a simpler appearance and structure, and more convenient for
transportation and operation.
Fl30F-M fixed integrated satellite broadband terminal can be flexibly installed on the wall, column and other
buildings or fixed with triangular support according to the situation of the site. It can be installed and debugged by
one person without building a special antenna foundation.
The fixed satellite broadband terminal is suitable for government agencies, enterprises and industry applications.
In the blind area of communication coverage, permanent or semi permanent communication blind compensation is
carried out; It is used to establish a variety of data transmission channels such as IoT (Internet of things), sensors,
field monitoring, etc., so as to reduce the dependence on ground network access services.
Figure 1-1 FL30F-M

2
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
2 Technical Specification
Antenna
Model No.
FL30F-M
Antenna Type
Horn waveguide array antenna
Equivalent to parabolic antenna size
0.3m
RF Performance
Frequency Range
Tx
14.00~14.50 GHz
Rx
10.70~12.75 GHz
Polarization
Linear Horizontal / Vertical
Rx Gain
31.2dBi(in range of ±10 degree)
3.11dBi(out range of ±10 degree)
Tx Gain
33.11dBi(in range of ±10 degree)
3.11dBi(out range of ±10 degree)
G/T
10dB/K, 25° Elevation
EIRP
44 dBW (16W BUC)
First Sidelobe
≤ -14dB
Power And RF Performance
DC Power Supply
DC24V ±5% (With AC Adapter)
Typical Satellite Modem
Select small-size Modems according to customer
requirements, such as IQ200, UHP210/220, etc.
Typical BUC
16W
Power Consumption
16W BUC
150W
Mechanical Performance
Satellite Acquisition
Manually pointing to satellite, level error<0.2°
Azimuth Range
±70°, fine adjustment ±5°
Elevation Range
10°~ 90° continues, fine adjustment ±5°
Polarization
±70°
Terminal Dimensions
(Exclude mounting bracket)
L 15.2 × W 13.8 × H 2.4 in.
L 385× W 350× H 60 mm
Terminal Weight
6 kg;
13.2 lbs.
Environmental Performance
Operational Wind
20.5m/s (74km/h)
Operational Temperature
-25°C to +50°C
Ingress Protection
IP66
Humidity
0 ~ 95%
Interfaces
Power
DC Power waterproof aviation connector
LAN
1 RJ45 10/100/1000
Other Function
Wireless Router
IEEE 802.11b/g/n at 2.4GHz

3
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
Access number: 30
Coverage (Unobstructed):50~100m
Bluetooth Device
V4.2
GNSS Device Supports
GPS/ BeiDou-2

4
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
3Packing List
Internal Packing of Terminal As Follows:
❖Waveguide array antenna (Equivalent aperture 0.30 m, including LNB and BUC modules)
❖Modem module (When the Modem is built in)
❖GPS module
❖Display module
❖ACU module
❖Power module
❖WiFi module
The basic configuration can be designed according to user requirements.
3.1 Unpacking and Inspection
When you receive the system containers, unpack and inspect the components and hardware to ensure that all parts
have been received in good condition.
3.2 Freight Damage
If any parts appear to have been damaged in transit, immediately contact the freight carrier.
3.3 Material-Missing or Damaged
If any parts appear to be missing or damaged, but not as a result of handling in transit, contact your dealer or
distributor.

5
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
3.4 Basic External Configuration of uSat Terminal
Item
Photo
Part Name
Quantity
Remarks
01
uSat Ku-band Fixed Flat Terminal
1
Standard
02
Bracket
1
Standard
03
Screw
1
Standard
04
Network Cable – 10m
CAT5 with two RJ-45 jacks
(Waterproof at the Terminal side)
1
Standard
05
24V Power Cable -10m
1
Standard

6
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
4Description of Fixed Terminal
4.1 Terminal Structure Diagram
The dimension drawing of the uSat Flat Terminal (Unit: mm), as shown in Figure 4-1.
Figure 4-1 Outline and Dimension Drawing

7
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
4.2 Terminal Installation Methods
1. The Terminal can be wall mounted (as shown in Figure 4-2) and hoop mounted (as shown in Figure 4-3)
on the pole.
Item
Description
Quantity
1
Prevailing torque type hexagon nuts with flange (with non-metallic insert) M6
4
2
Expansion Bolt
4
3
Wall
1
4
Bracket Assembly
1
5
Terminal Assembly
1
Figure 4-2 Wall Mount
Item
Description
Quantity
1
Pole Mount Support
1
2
U Bolt
2
3
Prevailing torque type hexagon nuts with flange (with non-metallic insert) M6
4
4
Bracket Assembly
1
5
Hexagon Bolts With Flange-Enlarge series B M6×12
4
6
Terminal Assembly
1
Figure 4-3 Pole Mount

8
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
2. The bracket installation diagram is shown in Figure 4-4, and the installation hole position is shown in
Figure 4-5.
Item
Description
Quantity
1
U Bolt
2
2
Prevailing torque type hexagon nuts with flange (with non-metallic insert) M6
4
3
Bracket Assembly-Cross bar
1
4
Bracket Assembly-Elevation Bracket
1
5
Bracket Assembly-Polarization Bracket
1
6
Prevailing torque type hexagon nuts with flange (with non-metallic insert) M6
4
7
Bracket Assembly-Azimuth Bracket
1
Figure 4-4 Installation of bracket
Figure 4-5 Mounting Hole Drawing
Hoop type installation: The outer diameter of the vertical pole is 3.5-5.5 inches (89-140mm), and the wall
thickness is ≥2mm.
DANGER
(1) The power supply requirement is 85-264VAC 50 / 60Hz

9
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
(2) If you work on a roof, tower or other high structure or use a ladder or scaffold to access the work site,
follow these precautions to prevent personal injury or death:
❖Walk only on sound roof structures.
❖Ensure that the antenna assembly and installation surface are structurally sound so that they can
support all loads (equipment weight, ice, and wind).
❖Use safety equipment (for example, a lifeline) appropriate for the work location.
❖Follow all manufacturer safety precautions for all safety and other equipment used.
❖Perform as many procedures as possible on the ground.
(3) Do not work in high wind or rain; or if a storm, lightning, or other adverse weather conditions are
either present or approaching.
(4) Do not connect the other side of the power cable to the power source until the terminal installation
completion.
4.3 Terminal Wireless Access Details
❖Terminal Serial No (S/N):
PMXXXXXXXXX (XXXX is the number of the following device)
❖MODEM:IQ200 (Take the IQ200 as example)
IP:192.168.0.1
User: admin Password: iDirect
❖Wi-Fi Router:
SSID: HILINK-XXX
Default IP Address: 192.168.16.254
User Name: admin Password: admin
❖Bluetooth:
Device Name: uSATXXXX
❖Polarization:
Tx(H); Rx(V)

10
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
5Terminal Installation, Initialization and Alignment
5.1 Terminal Installation
1. Fix the bracket on the Terminal firstly, and do not tighten the screws, as shown in Figure 5-1.
Figure 5-1 Fix the bracket on the Terminal
2. The bracket is fixed on the wall with expansion screw, as shown in Figure 5-2.
Figure 5-2 The bracket is fixed on the wall

11
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
DANGER
Do not connect the other side of the power cable to the power source until the terminal installation
completion.
3. Connect the power cable to the power debugging interface of the Fixed Terminal. The power requirement is
100-240VAC 50/60Hz, as shown in Figure 5-3.
Figure 5-3 Power Switch/Power Socket/Network Interface
NOTICE
Direction to the satellite must be clean from obstacles during the terminal operation.
Power
Switch
Power
Socket
Network
Interface

12
www.starwincom.com
Tel: +8629-88664381, E-mail: tech@starwincom.com
5.2 Terminal Initialization
1. Connect the Power cable to the Power Source. Upon connection, the display will show the Logo, as shown in
Figure 5-4.
Figure 5-4 LOGO
DANGER
The standard requirements to Power Source are 100-240VAC 50/60Hz. (Or 24V + 5% DC, according to
configuration for selection)
2. When the Terminal is powered on, the Terminal will display with indicator and abbreviated text. The display
icon description of system initialization is shown in Table 5-1. The first three items are main power supply
detection, general power supply, LNB power supply and BUC power supply. As shown in Figure 5-7, the
power quantity is displayed; when the self-test passes, it will be displayed as shown in Figure 5-8.
Table 5-1 System Initialization Icon Description
Indication
Indicator Flashes
General Power
Supply is in process
of detection
LNB Power Supply
is in process of
detection
BUC Power Supply
is in process of
detection
GNSS signal is in
process of detection
Attitude is in process
of detection
Indication
Indicator Lights
Continuously
General Power
Supply is detected
LNB Power Supply
is detected
BUC Power Supply
is detected
GNSS signal is
acquired
Attitude is detected
Figure 5-5 Battery Indicator
Table of contents
Popular Touch Terminal manuals by other brands

Elavon
Elavon Ingenico IWL 250 instruction manual

AGFA
AGFA Drystar Kiosk 5370/100 Operator's manual

Axon
Axon P900 Series manual

FEC
FEC AerPOS AP-3617 System manual

Network Computing Devices
Network Computing Devices ThinSTAR 300 user guide

National Instruments
National Instruments TB-2632B instruction manual