Digital compound LCD biological microscope are high-tech products ,integrated in microscope, digital LCD
screen, high-resolution professional digital cameras and high-capacity memory card. Our LCD Microscope can
be used both traditional eyepieces and an 9inches HD LCD Screen for easy and comfortable viewing for yourself
and to share with others. This patented microscope thoroughly resolves dizziness and fatigue caused by using a
traditional microscope at work for a long time. It is not only features high resolution of LCD display to reverting
genuine photo and video, but also features for quick and easy snapshots or short videos. This unit integrates
magnification, digital enlarge, imaging, display, capture photo and video, sarchiving and printing for easy
exchange, store captured photos and clips on the optional SD card or transfer them to your personal computer
via included USB cable. All of which achieve a more convenient and effective breakthrough.
I. Safety note
1. Carefully open the box, avoid the accessories, like lens, dropping to ground and being damaged.
2. Do keep the instrument out of direct sunlight, high temperature or humidity, dusty and easy shaking
environment. Make sure the stage is smooth, horizontal and firm enough.
3. When moving the instrument, please use two hands to grip with the two sides of the microscope body.
4. If the bacterium solution or the water splash to the stage, objective or viewing tube, pull out the power
cord at once, and wipe up the microscope. Otherwise, the instrument will be damaged. When running,
the lamp house and nearby parts will be very hot. Please ensure there is enough cooling room for
them.
5. Make sure the instrument is earthed, to avoid lighting strike.
6. For safety, be sure the main switch is in “O” (off) state before replace the halogen lamp or the fuse,
then cut off the power, and do the operation after the lamp bulb and the lamp house completely cool.
7. Check the input voltage: be sure the input voltage which signed in the back of the microscope is
consistent with the power supply voltage, or it will bring a serious damage to the instrument.(Note;
Use the factory supplied power cord 12v for binocular LCD display please.)
8. The mechanical stage is distortion and damage ,when it places on overweight object
II. Maintenance
1. All the lenses have been well checked and adjusted. It is forbidden to disassemble them yourself.
2. The nosepiece and coarse/fine focus unit have a compact and precise frame, please don’t disassemble
them as possible as you can.
3. Keep the instrument clean, wipe dust regularly, and be attention to avoid contaminating the optical
elements especially.
4. The contaminations on the prism, as finger mark and oil, could be gently wiped with a piece of soft
cloth or tissue paper, gauze which has been immersed in pure alcohol or xylene. (note that the alcohol
and the xylene are all burned easily, do not let them near the fire, and use them in a drafty room as