Sterling 2000HG Manual

2000HG
NEW STYLE HELICAL GEAR
RATIO MULTIPLIER
INSTALLATION AND MAINTENANCE MANUAL
May 4, 2017
Indianapolis, Indiana (800) 866-7973
e-mail: sales@sterlingelectric.com
www.sterlingelectric.com

2
7997 Allison Avenue, Indianapolis, IN 46268
Website: www.sterlingelectric.com
(800) 866-7973 FAX (317) 872-0907
email:sales@sterlingelectric.com
2000HG NEW STYLE HELICAL GEAR RATIO MULTIPLIER
INSTRUCTION MANUAL
SELECTION INFORMATION
Read ALL instructions prior to operating unit. Improper maintenance or operation may cause
injury to personnel or reducer failure.
Written authorization from Sterling Electric is required to operate or use this unit in man lift or
people moving devices.
Check to make certain application does not exceed the allowable load capacities published in
the current catalog.
Buyer shall be solely responsible for determining the adequacy of the product for any and all
uses to which buyer shall apply the product. The application by buyer shall not be subject to
any implied warranty of fitness for a particular purpose. Information contained in this manual is
considered correct at the time of publication and is subject to change without notice.
SAFETY ALERT
WARNING: For safety, purchaser or user should provide protective guards over all shaft
extensions and any moving apparatus mounted thereon. The user is responsible
for checking all applicable safety codes in his area and providing suitable guards.
Failure to do so may result in bodily injury and/or damage to equipment.
WARNING: Hot oil or gear units can cause severe burns. Use extreme care when removing
lubrication plugs and vents.
WARNING: Make certain that the power supply is disconnected before attempting to service
or remove any components. Lock out the power supply and tag it to prevent
unexpected application of power.
WARNING: Any brakes that are used in conjunction with this unit must be sized or positioned
in such a way as to not subject the unit to loads beyond the catalog rating.
CAUTION: Test run unit to verify operation. If the unit tested is a prototype, that unit must be
of current production.
CAUTION: If the unit cannot be located in a clear and dry area with access to adequate
cooling air supply, then precautions must be taken to avoid the ingestion of
contaminants such as water and the reduction in cooling ability due to exterior
contaminants. Units located in confined spaces may require forced air-cooling.

3
IMPORTANT INFORMATION
In the event of the resale of any of the goods, in whatever form, Resellers/Buyers will include
the following language in a conspicuous place and in a conspicuous manner in a written
agreement covering such sale:
The manufacturer makes no warranty or representations, expressed or implied,
by operation of law or otherwise, as to the merchantability or fitness for a
particular purpose of the good sold hereunder. Buyer acknowledges that it alone
has determined that the goods purchased hereunder will suitably meet the
requirements of their intended use. In no event will manufacturer be liable for
consequential, incidental or other damages.
Resellers/Buyers agree to also include this entire document including the warnings above in a
conspicuous place and in a conspicuous manner in writing to instruct users on the safe usage of
the product.
This instruction manual should be read together with all other printed information such as
catalogs, supplied by Sterling Electric.
GENERAL OPERATION
1. Run the motor, which drives the unit, and check the direction of unit output rotation. Consult
motor nameplates for instructions to reverse the direction of rotation.
2. Attaching the load: On direct-coupled installations, check shaft and coupling alignment
between unit and loading mechanism. On chain/sprocket and belt/pulley installation, locate
the sprocket or pulley as close to the oil seal as possible to minimize overhung load. Check
to verify that the overhung load does not exceed specifications published in the catalog.
3. High momentum loads: If coasting to a stop is undesirable, a braking mechanism should be
provided to the unit output or the driven mechanism.
CAUTION: The system of connected rotating parts must be free from critical speed,
torsional or other type vibration, no matter how induced. The responsibility
for this system analysis lies with the purchaser of the speed reducer.
INSTALLATION
1. Mount the unit using grade 5 or higher fasteners.
2. For shipment, solid plugs are installed in the unit along with a vent plug with transportation
lock which is pre-installed assuming standard horizontal mounting (M1). The vent plug will
need to removed and relocated if the unit is to be mounted in any positon other than the
standard horizontal positon as shown in the chart under LUBRICATION. After the unit is
mounted, completely remove the transportation lock from the vent plug as directed under
VENT PLUG LOCATION. Failure to vent the unit can cause premature seal wear or loss of
seal and oil. These conditions are not covered by warranty. Check for correct oil level.
Contact the factory for level and vent recommendations on non-standard mounting positions.
CAUTION: Do not operate the unit without making sure it contains the correct
amount of oil. Do not overfill or underfill with oil, or injury to personnel,
reducer or other equipment may result.

4
CAUTION: A unit cannot be used as an integral part of a machine superstructure
which would impose additional loads on the unit other than those imposed
by the torque being transmitted either through a shaft-mounted
arrangement, and any shaft mounted power transmitting device. (e.g.
sprockets, pulleys, couplings)
CAUTION: For safe operation and to maintain the unit warranty, when changing a
factory installed fastener for any reason, it becomes the responsibility of
the person making the change to properly account for fastener grade,
thread engagement, load, tightening torque and the means of torque
retention.`
LUBRICATION
CAUTION: On ALL quill style input units with a motor mounted vertical shaft up or
quill under on the input will require a double input seal arrangement to
prevent leakage or C-face coupled style units should be used. Consult
factory.
All standard helical ratio multipliers ordered from the factory are shipped with standard
compounded lubricant and is good for ambient temperature ranges of 30F to 104F. All
washdown and stainless steel helical ratio multipliers ordered from the factory are shipped with
synthetic NSF H1 Food Grade lubricant and are good for ambient temperature ranges of -10F
to 105F. Double reduction units have separate oil sumps and must be filled and checked
independently. Use of synthetics can cause problems if they are not compatible with the seals
or conventional lubes they replace. Prior to startup, verify that the oil is at the level shown
on the drawing below. If the ambient temperature will be outside the range for the lubricant
installed at the factory, drain and refill the reducer with the proper viscosity lubricant prior to use.
VENT PLUG LOCATION
Washdown and stainless steel units are supplied with a Heinrichs Breather with a rubber
transportation lock. The transportation lock must be completely removed before operation.
Failure to do so may cause the unit to leak. See below.
Before putting the unit into operation, it may be necessary to relocate the vent plug for positions
other than standard (M1). Substitute the vent plug for the solid plug at the position desired.
Install the solid plug in the location the vent plug was removed from. Refer to the following chart
for the recommended vent plug locations based on mounting position.

5
VENT/ LEVEL/ DRAIN LOCATIONS
M1
STANDARD POSITION
M2
M3
M4
M5
M6
NOTE: The unit is filled at the factory with the proper amount of oil for the STANDARD
mounting position. The level plug is for reference only so the unit can be checked for
proper oil level prior to installation and start-up. All other mounting positions will require the
oil level to be measured out prior to filling the unit based on the value in the table labeled
OIL CAPACITIES below.
CAUTION: On ALL quill style input units, cast iron and stainless with the input
mounted vertical shaft up or input under will require a double input seal
arrangement to prevent leakage or C-face coupled style units should be
used. Consult factory
OIL & WEIGHT SPECIFICATIONS
RECOMMENDED LUBRICATION OIL (ISO 150)
OIL CAPACITIES (FLUID OUNCE)
Mineral Oil
PAO†Synthetic
PAO†Synthetic H1
Food Grade
56C/140TC
180TC/210TC
Mobilgear
600XP-150
Mobil SHC 150
Mobil Cibus 150
14
16
†The use of PAG synthetics is not recommended.
Change Intervals: Standard compounded lubricants should be changed every six months or
2500 operating hours, whichever comes first. Synthetic lubricants should be changed every two
years or 6000 hours, whichever comes first.
CAUTION: Oil should be changed more often if the unit is used in a severe
environment. (i.e. dusty, humid)
CAUTION: In the Food and Drug Industry (including animal food), consult the
lubrication supplier for recommendation of lubricants which are
acceptable to the Food and Drug Administration and/or other authoritative
bodies having jurisdiction.

6
MAINTENANCE
Your Sterling Electric unit has been tested and adjusted at the factory. Dismantling or
replacement of components must be done by Sterling Electric to maintain the warranty.
Frequently check the oil level of the unit. If oil level is low, (refer to the vent and level position
chart) add proper lubrication through the filler plug until it comes out the oil level plug.
Inspect vent plug often to insure it is clean and operating.
CAUTION: Mounting bolts should be routinely checked to ensure that the unit is firmly
anchored for proper operation.
CLASS OF SERVICE
All capacity ratings are based on American Gear Manufacturers Association (AGMA) Standards.
Load conditions must be within cataloged ratings published in the current Sterling Electric
Catalog (available upon request).
LONG-TERM STORAGE (6 MONTHS UP)
Units must be stored indoors, in a dry, warm temperature.
Completely fill the unit with oil.
Rotate the input shaft so that the output shaft rotates at least one revolution per month.
Completely cover the input and output shaft with grease.
At the time of start up, drain the storage oil, install the breather, and fill to the proper oil level
with correct lubricant for the operating condition.
WARRANTY (LIMITED)
The warranty will cover all of the parts in the gearmotor or reducer unit for 12 months from the
date of shipment.
The warranty is only for parts and labor. In no event shall our liability exceed the original price
of the unit, nor does it cover cost of on site repair, installation, or freight.
Contact the service department for a complete explanation as to the full warranty policies and
conditions of sale.
All dimensions designs and specifications are subject to change without notice

7
SEAL AND BEARING SIZES
Input Bearing
Motor
Bearing Part Number and Size
Input
Series
OD (mm)
ID (mm)
Width (mm)
Sterling P/N
56C/140TC
6206
62
30
16
400-0008-9
180TC/210TC
6206
62
30
16
400-0008-9
ODE Output Bearing
Motor
Bearing Part Number and Size
Output
Series
OD (mm)
ID (mm)
Width (mm)
Sterling P/N
56C/140TC
6305
62
25
17
400-0495-5
180TC/210TC
6305
62
25
17
400-0495-5
DE Output Bearings
Motor
Bearing Part Number and Size
Input
Series
OD (mm)
ID (mm)
Width (mm)
Sterling P/N
56C/140TC
6206
62
30
16
400-0008-9
180TC/210TC
6207
72
35
17
400-0009-7
Input Seal
Motor
Bearing Part Number and Size
Input
Shaft (mm)
Bore (mm)
Width (mm)
Sterling P/N
56C/140TC (Item #4)
35
50
8
404-0292-8
56C/140TC (Item #15)*
35
62
7
404-0350-0
180TC/210TC (Item #21)
50
60
8
404-0377-3
180TC/210TC (Item #24)*
50
62
7
404-0452-8
*Only present on units with double input seal option.
Output Seal
Motor
Bearing Part Number and Size
Output
Shaft (mm)
Bore (mm)
Width (mm)
Sterling P/N
56C/140TC
30
50
7
404-0291-9
180TC/210TC
35
55
8
404-0294-6

8
56C/140TC PARTS
Item
No.
Description
Qty
Item
No.
Description
Qty
1
INPUT QUILL SHAFT
1
13
HEINRICHS BREATHER
1
2
BALL BEARING
2
14
SEAL PLUG
4
3
EXTERNAL SNAP RING
1
15
METRIC SEAL
1
4
METRIC SEAL
1
16
SPACER RING/ SPLASH GUARD
1
5
METRIC SEAL
1
17
SOLID OUTPUT GEAR
1
6
BALL BEARING
1
18
PINION
1
7
SOCKET HEAD CAP SCREW
10
19
SPACER
1
8
O-RING
1
20
SS2RBQ ONE PIECE HOUSING
1
9
METRIC KEY
1
21
C-FACE OUTPUT CAP
1
10
SLINGER
1
22
OUTPUT SHAFT
1
11
KEY
1
23*
O-RING
1
12
INTERNAL SNAP RING
1
24
INPUT FLANGE
1
*Applies to Stainless Steel units only.

9
180TC/210TC PARTS
Item
No.
Description
Qty
Item
No.
Description
Qty
1
ONE PIECE HOUSING
1
14
C-FACE OUTPUT CAP
1
2
BALL BEARING
1
15
SOCKET HEAD CAP SCREW
6
3
EXTERNAL SNAP RING
1
16
OUTPUT SHAFT
1
4
BALL BEARING
1
17
BALL BEARING
1
5
SPACER
1
18
METRIC SEAL
1
6
O-RING
1
19
KEY
1
7
METRIC KEY
1
20
INPUT FLANGE
1
8
INTERNAL SNAP RING
1
21
INPUT QUILL SHAFT
1
9
HEINRICHS BREATHER
1
22
METRIC SEAL
1
10
SEAL PLUG
4
23
SOCKET HEAD CAP SCREW
4
11
PINION
1
24
V-SEAL
1
12
OUTPUT GEAR
1
25
METRIC SEAL
1
13
SPACER RING/ SPLASH GUARD
1
26*
O-RING
1
*Applies to Stainless Steel units only.

10
Indianapolis, Indiana (800) 866-7973
e-mail: sales@sterlingelectric.com
www.sterlingelectric.com
Table of contents
Popular Industrial Equipment manuals by other brands

Twister
Twister batchone GO user manual

Bosch
Bosch BS 2/R Assembly technology

SMC Networks
SMC Networks MWB-X3075 Series Original instructions

Jung
Jung 505KO5VEUM Series quick start guide

GCC Technologies
GCC Technologies Laser Pro DFS Installation & operation manual

Aerotech
Aerotech BA50 Series Hardware manual