DANGER
WARNING
FOREWORD
Thank you for purchasing a generator.
This manual covers operation and maintenance of the generators.
All information in this publication is based on the latest production
information available at the time of approval for printing.
Pay special attention to statements preceded by the following words:
The generator is designed to give safe and dependable service if
operated according to instructions.
Do not operate the generator before you have read and understood
the instructions. Failure to do so could result in death, personal
injury or equipment damage.
Indicates a strong possibility of severe personal injury, loss of life and
equipment damage if instructions are not followed.
[CAUTION]
Indicates a possibility of personal injury or equipment damage if instructions
are not followed.
NOTE:
Gives helpful information.
If a problem should arise, or if you have any questions about the generator,
consult an authorized dealer or service shop
Indicates a possibility of death or serious injury if instructions are not
followed.
WARNING
SGX7500usGU7064.indd01
SGX7500usGU7064.indd01
2010/07/2214:04:36
2010/07/2214:04:36

ENGLISHFRANÇAISEESPAÑOL
CONTENTS
1. SAFETY PRECAUTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. PRE-OPERATION CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5. OPERATING PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.WATTAGE INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7. SPARK ARRESTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8. MAINTENANCE SCHEDULE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9. ”HOW-TO” MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
10. PREPARATION FOR STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
11.TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
12. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
13. ASSEMBLY PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SGX7500usGU7064.indd02
SGX7500usGU7064.indd02
2010/07/2214:04:37
2010/07/2214:04:37

ENGLISHFRANÇAISEESPAÑOL
-
1
-
1. SAFETY PRECAUTIONS
Please make sure you review each precaution carefully.
Do not operate the generator near gasoline or gaseous fuel because of the
potential danger of explosion or fire.
Do not fill the fuel tank with fuel while the engine is running. Do not smoke or
use open flame near the fuel tank. Be careful not to spill fuel during refueling.
If fuel is spilt, wipe it off and let dry before starting the engine.
Do not place in flammables near the generator.
Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in flammables
near the generator.
Do not enclose the generator nor cover it with a box.
The generator has a built-in forced air cooling system, and may become overheated if it is enclosed.
If generator has been covered to protect it from the weather during non use, be sure to remove it and
keep it well away from the area during generator use.
1m
1m
Operate the generator on a level surface.
It is not necessary to prepare a special foundation for the generator.
However, the generator will vibrate on an irregular surface, so choose a level place without surface
irregularities.
If the generator is tilted or moved during operation, fuel may spill and / or the generator may tip over,
causing a hazardous situation.
Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such
a case, piston seizure may occur even if the oil is above the upper level.
Pay attention to the wiring or extension cords from the generator to the connected device.
If the wire is under the generator or in contact with a vibrating part, it may break and
possibly cause a fire, generator burnout, or electric shock hazard.
Replace damaged or worn cords immediately.
Do not operate the generator inside a room, cave, tunnel, or other
insufficiently ventilated area.
Always operate it in a well-ventilated area, otherwise the engine may
become overheated, and the poisonous carbon monoxide gas, an
odorless, colorless, poison gas, contained in the exhaust gas will
endanger human lives.
Operate generator only outdoors and far from open windows, doors,
ventilation intakes and other openings.
Keep the generator at least 1 meter (3 feet) away , including overhead,
from any structure or building use.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
SGX7500usGU7064.indd1
SGX7500usGU7064.indd1
2010/07/2214:04:37
2010/07/2214:04:37

ENGLISHFRANÇAISEESPAÑOL
-
2
-
Do not contact the generator to a commercial power line. Connection to a commercial
power line may short circuit the generator and ruin it or cause electric shock hazard.
Use the transfer switch for connecting to domestic circuit.
Engine becomes extremely hot during and for some time after operation.
Keep combustible materials well away from generator area.
Be very careful not to touch any parts of the hot engine especially the muffler area
or serious burns may result.
No smoking while handling the battery. The battery emits flammable hydrogen gas,
which can explode if exposed to electric arcing or open flame.
Keep the area well-ventilated and keep open flames/sparks away when handling the battery.
Do not operate in rain, in wet or damp conditions, or with wet hands.
The operator may suffer severe electric shock if the generator is wet due to rain or snow.
Keep children and all bystanders at a safe distance from work areas.
If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it
with water.
Be extremely careful that all necessary electrical grounding procedures are followed during each and
every use. Failure to do so can be fatal.
It is absolutely essential that you know the safe and proper use of the power tool or appliance that you
intend to use. All operators must read, understand and follow the tool/appliance owners manual. Tool
and appliance applications and limitations must be understood. Follow all directions given on labels
and warnings. Keep all instruction manuals and literature in a safe place for future reference.
Use only "LISTED" extension cords.
When a tool or appliance is used outdoors, use only extension cords marked "For Outdoor Use".
Extension cords, when not in use should be stored in a dry and well ventilated area.
Always switch off generator's AC circuit breaker and disconnect tools or appliances when not in use,
before servicing, adjusting, or installing accessories and attachments.
Make sure the engine is stopped before starting any maintenance, servicing or repair.
Make sure maintenance and repair of the generator set are performed by properly trained personnel only.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
CAUTION
SGX7500usGU7064.indd2
SGX7500usGU7064.indd2
2010/07/2214:04:37
2010/07/2214:04:37

ENGLISHFRANÇAISEESPAÑOL
-
3
-
2. SPECIFICATIONS
MODEL SGX3500 SGX5000 SGX7500
Generator
Type Brush, self-exciting, 2-poles, single phase
Voltage regulating system AVR type
AC Output
Rated voltage-Frequency V-Hz 120/240-60
Rated current A 26.6/13.3 37.5/18.7 55.8/27.9
Rated output VA (W) 3200 4500 6700
Maximum output VA (W) 3500 4900 7300
Rated power factor 1.0
Safety device type Fuse-less circuit breaker
Engine
Model EX21D EX30D EX40D
Type SUBARU, Air-cooled, 4-stroke, OHC, Gasoline Engine
Displacement mL (cu.in.) 211 (12.88) 287 (17.51) 404 (24.65)
Fuel Automotive unleaded gasoline
Fuel Tank Capacity L (U.S.gal) 11.0 (2.91) 20.0 (5.28) 22.5 (5.94)
Engine oil capacity L (U.S.gal) 0.6 (0.16) 1.0 (0.26) 1.2 (0.32)
Spark plug TORCH E6RC
(NGK BR-6HS) NGK BR-6HS
Starting system Recoil starter Electric starter /
Recoil
Direction of rotation Counter - clockwise
Dimension
Length mm (in.) 685 (27.0) 770 (30.3) 845 (33.3)
Width mm (in.) 630 (24.8) 690 (27.2)
Height mm (in.) 635 (25.0) 665 (26.2)
Dry Weight kg (lb) 55.0 (121) 69.5 (153) 96.0 (212)
Specifications are subject to change without notice.
NOTE
Dimensions and dry weight include two wheels, handles and battery.
In dimensions, handles are measured being closed.
SGX7500usGU7064.indd3
SGX7500usGU7064.indd3
2010/07/2214:04:37
2010/07/2214:04:37

ENGLISHFRANÇAISEESPAÑOL
-
4
-
3. COMPONENTS
Tank cap Fuel gauge
Control panel
Oil gauge (oil filler)
Oil drain plug
Recoil starter
Recoil starter
handle
Fuel tank
Spark plug cap
Air cleaner
Choke lever
Spark arrestor
Muffler
SGX7500usGU7064.indd4
SGX7500usGU7064.indd4
2010/07/2214:04:37
2010/07/2214:04:37

ENGLISHFRANÇAISEESPAÑOL
-
5
-
CONTROL PANEL
[Electric starter model]
Key switch
(
SGX3500
)
(SGX7500)
(
SGX5000
)
Hour meter
Hour meter
Hour meter
AC receptacle
20A (MAX 13A)
AC receptacle
20A (MAX 19A)
AC receptacle
20A (MAX 19A)
AC receptacle
20A (MAX 20A)
AC receptacle 20A (MAX 13A)
Earth (ground)
terminal
Earth (ground)
terminal
Earth (ground)
terminal
AC circuit
breaker
AC circuit
breaker
AC receptacle
30A (MAX 28A)
AC circuit
breaker
AC circuit
breaker
Oil warning
lamp
SGX7500usGU7064.indd5
SGX7500usGU7064.indd5
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
6
-
4. PRE-OPERATION CHECKS
Upper level
Oil filler cap
(Oil gauge)
Lower level
CHECK ENGINE OIL
Before checking or refilling oil, be sure
generator is located on stable and level
surface with engine stopped.
Remove oil filler cap and check the
engine oil level.
If oil level is below the lower level line,
refill with suitable oil (see table) to
upper level line. Do not screw in the
oil filler cap when checking oil level.
Change oil if contaminated.
(See "How-To" Maintenance.)
Oil capacity (Upper level) : L (U.S. gal)
SGX3500 . . . . . . . . . . . . . . .0.6 (0.16)
SGX5000 . . . . . . . . . . . . . . .1.0 (0.26)
SGX7500 . . . . . . . . . . . . . . .1.2 (0.32)
Recommended engine oil:
Use 4-stroke automotive detergent
oil of API service class SE or
higher grade (SG, SH or SJ is
recommended). SAE 10W-30
or 10W-40 is recommended for
general, all-temperature use. If
single viscosity oil is used, select
the appropriate viscosity for the
average temperature in your area.
Ambient
temperature
Single grade
Multigrade
5W
10W
20W
#20
#30
#40
10W
-
30
10W
-
40
SGX7500usGU7064.indd6
SGX7500usGU7064.indd6
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
7
-
Check fuel level at fuel level gauge.
If fuel level is low, refill with
unleaded automotive gasoline.
Be sure to use the fuel filter screen
on the fuel filter neck.
Fuel Amount
up to “LEVEL” position : L (U.S. gal)
SGX3500 . . . . . . . . . . . . . .11.0 (2.91)
SGX5000 . . . . . . . . . . . . . .20.0 (5.28)
SGX7500 . . . . . . . . . . . . . .22.5 (5.94)
LEVEL
Fuel filter screen
Fuel tank cap
FULL
EMPTY
Do not refuel while smoking or near open flame or other such potential
fire hazards. Otherwise fire accident may occur.
CHECK ENGINE FUEL.
Make sure you review each warning in order to prevent fire hazard.
Do not refill tank while engine is running or hot.
Close fuel valve before refueling with fuel.
Be careful not to admit dust, dirt, water or other foreign objects Into
fuel.
Wipe off spilt fuel thoroughly before starting engine.
Keep open flames away.
NOTE :
THIS ENGINE IS CERTIFIED TO OPERATE
ON AUTOMOTIVE UNLEADED GASOLINE.
WARNING
WARNING
SGX7500usGU7064.indd7
SGX7500usGU7064.indd7
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
8
-
CHECKING COMPONENT PARTS
Check following items before starting engine:
Fuel leakage from fuel hose, etc.
Bolts and nuts for looseness.
Components for damage or breakage.
Generator not resting on or against any adjacent wiring.
CHECK GENERATOR SURROUNDINGS
Make sure you review each warning in order to prevent fire hazard.
Keep area clear of in flammables or other hazardous materials.
Keep generator at least 3 feet (1 meter) away from buildings or other
structures.
Only operate generator in a dry, well ventilated area.
Keep exhaust pipe clear of foreign objects.
Keep generator away from open flame. No smoking!
Keep generator on a stable and level surface.
Do not block generator air vents with paper or other material.
Battery Box
Gasket
Gasket
(Battery Hold Down Bracket)
Battery Hold
Down Bracket
Battery Cable
(Red)
Battery Cable
(Black)
Lock Nut
Washer
Bolt
WARNING
BATTERY INSTALLATION (Electric Starter Model)
Recommended Battery
Type ; Lead-acid battery (SEALAKE FM12180)
Capacity (Ah/20hr) ; 12V-18AH
Size ; 178(L) x 75(W) x 167(H) mm
SGX7500usGU7064.indd8
SGX7500usGU7064.indd8
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
9
-
Death, personal injury and/or property damage may occur unless
instructions are followed carefully.
Use battery of recommended capacity.
Turn the starter switch to the “STOP” position when mounting or
dismounting battery. When mounting battery, connect the positive (+)
cable first and then the negative (
-
)
cable to the battery. Be careful not to
short battery cables.
When dismounting battery, disconnect negative (
-
)
cable first.
RED CABLE : To positive (+) terminal
BLACK CABLE : To negative (
-
) terminal
Should the connection be made in incorrect manner, the generator will
be broken.
Tighten bolts and nuts on terminals securely so they will not be
loosened by vibration.
Disconnect battery cables when charging battery.
WARNING
GROUNDING THE
GENERATOR
To ground the generator to the earth,
connect the grounding lug of the
generator to the grounding spike
driven into the earth or to the
conductor which has been already
grounded to the earth.
If such grounding conductor or
grounding electrode is unavailable,
connect the grounding lug of the
generator to the grounding terminal of
the using electric tool or appliance.
Grounding spike
SGX7500usGU7064.indd9
SGX7500usGU7064.indd9
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
10
-
5. OPERATING PROCEDURES
(a) Turn the Engine switch to the position
"ON". (Except SGX7500)
(b) Turn the AC circuit breaker to the
position "OFF".
(c) Open the fuel valve.
(d) Set choke lever to close if the engine
is cold.
STARTING THE GENERATOR
Check the oil level before each operations as outlined by the article
"CHECK ENGINE OIL"
[CAUTION]
ON
OFF
CLOSE
OPEN
Choke lever
CLOSE
OPEN
ON
OFF
OFF
SGX7500usGU7064.indd10
SGX7500usGU7064.indd10
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
11
-
Pull briskly
(e) [Recoil starter model]
Pull the starter handle slowly until
passing the compression point
(resistance will be felt), then return
the handle to its original position
and pull briskly.
If the engine fails to start after several
attempts, repeat above procedures
with choke lever returned to "OPEN"
position.
Do not fully pull out the rope.
After starting, allow the starter handle
to return to its original position while
still holding the handle.
(f) [Electric starter model]
Insert the key into the key switch and
turn it clockwise to the "RUN" position
to start the engine.
Then turn the key further to the
"START" position. The engine will be
started by starting motor.
RUN
STOP
STOP
RUN
START
START
Do not run the starting motor over 5 seconds continuously.
If the engine fails to start, return the key to the "RUN" position and wait
about 10 seconds then start again.
Do not turn the key switch to "START" position when the engine is running
to prevent damage of starting motor.
When starting the engine by recoil starter, set the key switch at the "RUN"
position and pull the starter handle.
[CAUTION]
SGX7500usGU7064.indd11
SGX7500usGU7064.indd11
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
12
-
(g) After the engine started, return the
choke lever gradually to "OPEN"
position.
Choke lever
CLOSE
OPEN
(h) Warm up the engine without a load for
a few minutes.
SGX7500usGU7064.indd12
SGX7500usGU7064.indd12
2010/07/2214:04:38
2010/07/2214:04:38

ENGLISHFRANÇAISEESPAÑOL
-
13
-
(a) Make sure the pilot lamp is turned on.
(b) Turn off the switch (es) of the electrical
appliance (s) before connecting to the
generator.
(c) Insert the plug (s) of the electrical
appliance(s) into the receptacle.
(1) AC APPLICATION
USING ELECTRIC POWER
Make sure that the appliance is switched OFF before connecting it to
the generator.
Do not move the generator while it is running.
Be sure to ground the generator if the connected appliance is
grounded. Failure to ground unit may lead to electrical shock.
Check the amperage of the receptacles used referring to TABLE 1, and be
sure not to take a current exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated
output of the generator.
WARNING
SGX7500usGU7064.indd13
SGX7500usGU7064.indd13
2010/07/2214:04:39
2010/07/2214:04:39

ENGLISHFRANÇAISEESPAÑOL
-
14
-
NOTE :
When the AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check
the appliance and / or generator for overloading or detect and have repaired as
necessary by Robin America dealer or service shop.
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.
Be sure to ground the generator if
the connected electrical device Is
grounded.
TWIST
Style Ampere Receptacle AC plug Description
up to 20A NEMA
5-20R
NEMA
5-20P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex
up to 20A NEMA
L5-20R
NEMA
L5-20P Locking Receptacle
up to 20A NEMA
L14-20R
NEMA
L14-20P Locking Receptacle
up to 30A NEMA
L5-30R
NEMA
L5-30P Locking Receptacle
up to 30A NEMA
L14-30R
NEMA
L14-30P Locking Receptacle
TABLE 1
WARNING
SGX7500usGU7064.indd14
SGX7500usGU7064.indd14
2010/07/2214:04:39
2010/07/2214:04:39

ENGLISHFRANÇAISEESPAÑOL
-
15
-
(d) Turn the AC circuit breaker to the
position "ON".
(e) Turn on the switch of the appliance.
ON
ON OFF
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
[CAUTION]
GFCI RECEPTACLE
After starting the engine, check the GFCI for proper functioning by the following test
procedure.
Push blue TEST button, The red RESET button will pop out exposing the word
TRIP. Power is now off at the outlets protected by the GFCI, indicating that the
device is functioning properly.
If TRIP dose not appear when testing, do not use the generator. Call a qualified
electrician.
To restore power, push RESET button.
If the RESET button pops out during operation, stop the generator
immediately and call a qualified electrician for checking generator and
the appliances.
WARNING
SGX7500usGU7064.indd15
SGX7500usGU7064.indd15
2010/07/2214:04:39
2010/07/2214:04:39

ENGLISHFRANÇAISEESPAÑOL
-
16
-
STOPPING THE GENERATOR
(a) Turn off the power switch of the
electric equipment and unplug the cord
from receptacle of the generator.
(b) Turn the AC circuit breaker to the
"OFF" position.
(c) Allow the engine about 3 minutes to
cool down at no-load before stopping.
(d) [Recoil starter model]
Turn the engine switch to the position
"OFF".
[Electric starter model]
Turn the key switch to the STOP
position.
(e) Close the fuel valve.
OIL SENSOR
(a) The oil sensor detects the fall in oil
level in the crankcase and automati-
cally stops the engine when the oil
level falls below a predetermined level.
(b) When engine has stopped
automatically, switch off generator's
AC circuit breaker, and check the oil
level.
Refill engine oil to the upper level as
instructed on page 6 and restart the
engine.
(c)If the engine does not start by usual
starting procedures, check the oil level.
CLOSE
OPEN
Oil sensor
ON
OFF
ON
OFF
STOP RUN
STOP
RUN
START
START
SGX7500usGU7064.indd16
SGX7500usGU7064.indd16
2010/07/2214:04:39
2010/07/2214:04:39

ENGLISHFRANÇAISEESPAÑOL
-
17
-
6.WATTAGE INFORMATION
Some appliances need a "surge" of energy when starting.
This means that the amount of electrical power needed to start the appliance may
exceed the amount needed to maintain its use.
Electrical appliances and tools normally come with a label indicating voltage, cycles /
Hz, amperage (amps) and electrical power needed to run the appliance or tool.
Check with your nearest dealer or service center with questions regarding power
surge of certain appliances or power tools.
Electrical loads such as incandescent lamps and hot plates require the same
wattage to start as is needed to maintain use.
Loads such as fluorescent lamps require 1.2 to 2 times the indicated wattage
during start-up.
Loads for mercury lamps require 2 to 3 times the indicated wattage during start-up.
Electrical motors require a large starting current. Power requirements depend on
the type of motor and its use. Once enough "surge" is attained to start the motor,
the appliance will require only 50% to 30% of the wattage to continue running.
Most electrical tools require 1.2 to 3 times their wattage for running under load
during use. For example, a 5,000 watt generator can power a 1800 to 4000 watt
electrical tool.
Loads such as submersible pumps and
air compressors require a very large force
to start. They need 3 to 5 times the normal running wattage in order to start.
For example, a 5,000 watt generator would only be able to drive a 1,000 to
1,700 watt pump.
NOTE:
The following wattage chart is general guide only. Refer to your specific appliance
for correct wattage.
To determine the total wattage required to run a particular electrical appliance or
tool, multiply the voltage figure of the appliance/tool by the amperage (amps) figure
of same. The voltage and amperage (amps) information can be found on a name
plate which is normally attached to electrical appliances and tools.
Applications Applicable Wattage(W)
SGX3500 SGX5000 SGX7500
Incandescent lamp, Heater 3200 4500 6700
Fluorescent lamp, Electric tool 1750 2500 3700
Mercury lamp 1250 1800 2650
Pump, Compressor 800 1100 1650
SGX7500usGU7064.indd17