sugar-valley HIDROLIFE SAL16 User manual

Electronic unit
HIDROLIFE
QUICK INSTALATION GUIDE
Electrolysis
RCA flow detector
pH probe
Redox probe
Mains connection 220v.
3.15A fuse
250 mA fuse
On-off switch
Air vent
Acid pump connection
2
3
4
5
6
7
8
9
10
11
DESCRIPTION
1
Cell
Electrolysis cell
RCA flow detector
Cell connector
Flow/gas detector
1
2
3
Optional extras
pH Probe Conductividad ProbeRedox Probe
Cell housing
Probe
Probe casing
Connection housing
1
2
31
2
3
1
2
3
1
2
3
5
4
10
7
8
9
6
2
34
5
11
10
2
5
1
4
3
ThesaltwaterelectrolysisproducesChlorineonthebasesofsaltwateroflowsalinity(approximately5gSaltperlitre).As
the swimming pool water containing the salt flows through the electrolysis cell, the salt is converted to Sodium-hypo-
chloride (liquid chlorine). Organic mater present in the water is oxidised and eliminated by the chlorine. The Sodium-
hypo-chloridereconvertsintosaltonitswaybacktotheswimmingpool.
Probe
Probe casing
Connection housing
1
2
3
Probe
Probe casing
Connection housing
1
2
3

INSTALATION
2
System instalation diagram
Electrolysis cell (always in vertical position)
1
Filtration pump timer
ASand filter
BRecirculation pump
C
pH probe (Optional, for models with pH control)
3
Redox probe(Optional, for models with redox control)
4
Electrical housing
5Conductivity probe (Optional, for models with conductivity control)
6
Chlorine pump
(Optional, for models with redox or free chlorine control + auxiliary chlorine dosage)
11
Chlorine injector (Optional, for models with redox or free chlorine control)
12
Chlorine container (Optional, for models with redox or free chlorine control,
not supplied with unit)
13
10 Hydrochloric acid container
(optional, for models with PH control, not supplied with unit)
Acid pump (Optional, for models with PH control)
8Acid injector (Optional, for models with PH control)
9
Other pool equipment
(pool heating, heat exchanger, etc,)
15
Electrical consumption
HIDROLIFEsynchronizedwithFILTRATION
Ensure the electrolysis unit is synchronized with the pool filtration and stops functioning when
watercirculationhasstopped.
TITANIUMCELLconnectionoverheating
Ensure all electrical connections are firmly fixed to avoid false contacts and
subsequent overheating of system components (Especially concerning the
electrolysiscellwithusageabove33A).
A
B
C
1
3
4
5
6
15
13 12
11
10
9
8
min. 1m
SAL16
SAL22
SAL33
SAL50
SAL85
SAL125
180W
205W
228W
600W
1020W
1440W
Recommended
protection
Maximum
consumption 10A
10A
16A
16A
25A
25A
SAL175
SAL250 2040W
2880W 25A
25A
grCl2/h
16
22
33
50
85
125
175
250

Electronic housing display
ALARM
Excessiveincreaseor decreaseinparameters (+/-15%
fromtheselectedparameters).
CHECKLEVELSINACID/BASECONTAINERS
CHECKPROBECALIBRATION
InsufficientFLOWorcelldisconnected
Production halted due to lack of flow, or gas in the
titaniumcelldetector.
ONLY SYSTEMS WITH FREE CHLORINE CONTROL
(ppm's)
INSUFFICIENT FLOW in the CHLORINE detector. The
rotary sensor detects insufficient flow. CHECK the
rotameter pendel – and solve the system's hydraulic
problem (If there is a preceding filter this must be
cleaned).
Conductivity/Celllife
Lowconductivity(Seesection3)
Titaniumcellincrusted(Seecleaningprocessinsection5)
Cellsurfacecorroded(Seesection7)
ONLYSYSTEMSWITHREDOXORFREECHLORINE
The system has automatically stopped as Redox levels
areabovethechosenvalues(Seesection5)
Timedelay
Period of non-production of oxidant while system
changespolarity(0-120sec.)
Status led's
Electrolysis production
ENTER button
Right button
Left button
START UP
4
INITIAL ADJUSTMENTS
3
Water adjustments
1.Adjust the alkalinity between 90 and 110
ppm.
2.AdjustthePHbetween7,2and7,4
3.Adjust the chlorine between 1 and 1,5
ppm.
SHOULD the water be supplied from a well:
shock chlorinate with Tricloroisocyanuric
acid(2Kg./50m3ofwater)
Adding Salt to the Water
Start up
Add5to6GrammSalt(withoutYod)foreachlitreofwaterinyourswimmingpool(5to6
kgNaClperm3Water).Openthebottomvalveofyourswimmingpooland addthe Salt
directly to your swimming pool water. Let the circulation pump run during the first 24
hours your Hidrolife system is working in order to dissolve the Salt completely. Your
hidrolifeSystemwilloperatewithoutanyproblemswithsaltconcentrationsfrom2,5gto
50gSaltperlitre.
IN POOLS WHICH RECEIVE LARGEAMOUNTS OF STRONG SUNLIGHT 40gr/m3
OFSTABILYSER(Isocyanuricacid)MUSTBEADDED
Up button
Down button
pH Probe
Conductivity probe/
water temperature
Free Chlorine/Redox
TheHidrolifesystemcanbeusedinSPA´stoproduceBromine:Add0,12KgofSodiumBromineforeachm3ofWater(inconjunctionwiththenormalsalt
concentration-seeabove).Hidrolife/BionetwillgenerateenoughBrominetopurifyyourspa.

MAINTENANCE
6
1-Thepoolmustbevacuumedasusualandtheskimmersemptiedwhenevernecessary.
2-Filter backwashing: with Sugar Valley systems the filter requires only occasional backwashing; once every 20 days should be sufficient (providing the filter pressure does
notexceed1bar,inwhichcaseabackwashmaybenecessary).
3-ADDING NEW WATER:Always through the skimmers so that the new water passes through the Hidrolife before entering the pool. Remember to add the necessary salt:
6gr.peraddedlitreofwater.
4-InwinterCHANGINGTHEPOOLWATERISNOTRECOMMENDABLE.Werecommendthatthesystemruns2-3timesperweek(2-3hrs.perday).
DOSAGE PUMPS: Check regularly to ensure that the container contains liquid to prevent the dosage pump running dry. The dosage pump requires maintenance
(INSTRUCTIONSONBOX).
PH PROBES/REDOX/CONDUCTIVITY: Probes must be cleaned whenever necessary (check every 5-6 months). To clean the probe insert in distilled water (Clear liquid).
Aftereachcleaningtheprobesmustbecalibrated.
General maintenance
VERY IMPORTANT; Ensure that the system is turned off during filter backwashing.
FREE chlorine : 1.0 – 2.0 PPM
pH : 7,1 – 7,5
Fortnightly checks
TOTALalkalinity(TAC) :80-120ppm
Saltconcentration : 4.000–6.000ppm
Cyanuricacid : 30-50ppm
Titaniumcell :Visualinspectiontodetectincrustations.
Monthly checks
SYSTEMS WITH REDOX CONTROL
5
CleaningtheTitaniumcell:Maintenanceofthedisinfectionsystem(Electrolysis)consistsofcleaningthecellorelectrodeevery2-3monthsshoulditappearnecessary(carry
outavisualinspection)Tocleantheelectrode:
-Removethecellfromitssupport(afterturningoffthefiltrationsystemandclosingoffthenecessaryvalves).
-Placetheelectrodefornomorethan10min.in15%HYDROCHLORICACID(salfumant).1,5lofacidforeach8,5lofwater.
-Oncetheincrustationshavesoftenedremovewithahosetocompletecleaningthecell.
USE NO METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it vulnerable to chemicals, deteriorate the
cellandannultheguarantee.
Titanium cell maintenance
Duringthefirst10-15daysyourpoolsystemwillrequiremoreattentionandthefollowingcare:
1CHECK THE PH REMAINS BETWEEN THE IDEAL LEVELS (7,2-7,4). If the PH is unusually unstableAND USESA LOTOFACID check the alkalinity (Recommended
levelsbetween80and125ppm.).
2Thepoolmustbevacuumedandtheskimmerscleanedwhenevernecessarytoensureperfectwaterconditions.
REMEMBER
thattheSugarValleysystemrequiresacertainamountoftimetoadapttoyourswimmingpoolandwillrequireadditionalchemicalsduringthefirst3-5days.
Initial days of maintenance
The Redox level advises us of the potential oxidization or reduction level and is used to determine the level of water sterilization. The parameters or Set Points are the
minimum/maximumacceptedREDOXlevelsbeforethetitaniumcellisconnected/disconnected.
AdjustingtheidealREDOXlevel(setpoint)isthelaststepintheHIDROLIFEstartupsequence.TofindtheoptimumREDOXlevelforyourpoolfollowthesesteps:
1. Connectthepoolfiltrationsystem(Thesaltinthepoolmustbeadequatelydissolved)
2. Addchlorinetothepooltillalevelof1-1,5ppm.Isachieved(Approx.1-1,5gr/m3ofwater).PHlevelsshouldbebetween7,2and7,5.
3. After 30 min. test the free chlorine levels in the pool (DPD1 manual test kit) If the free chlorine level is between 0,8-1,0ppm. Look at the REDOX screen and memorize
thislevelasthesetpointtoCONNECT/DISCONNECTthehydrolysiscell(Tomemorizethesetpointseesection8)
4. Thenextdaycheckfreechlorinelevels(manualDPD1testkit)and REDOX,Raise/lowersetpointifnecessary

MENU ACCESS
7
q
Hold for 3 seconds to access/exit user menu
Accessing user menu
User menu
pH SET POINTS
To modify parameters/maximum pH set point
To LOWER pH - maximum water pH - CONTROLS THEACID PUMP (optional equipment)
CHLORINE PRODUCTION LEVEL
To modify level
To confirm and change menu
To modify parameters/minumum pH set point
To INCREASE pH - minimum water pH - CONTROLS THE BASE PUMP (optional equipment)
pH PROBE CALIBRATION
Insert probe in pH 7 sample,
wait till reading has stabilized
Clean probe in NEUTRAL.
Insert probe in pH 10
sample and wait till reading
is stable.
REDOX SET POINT
To modify parameters/Redox set point To confirm and change menu
REDOX PROBE CALIBRATION
Insert probe into 465mv sample,
wait till reading is stable
CONDUCTIVITY SET POINT
To modify parameters/conductivity set point To confirm and change menu
CONDUCTIVITY PROBE CALIBRATION
Insert the probe in
sample, wait until reading
is stable.
To change menu
and return to Ion menu.
Displays
Conductivity control
5
Redox/Free chlorine control
pH control
Electrolysis level
4
3
2
1
q
Insert the probe in
sample, wait until
reading is stable.
Calibration correct
Repeat calibration or
change probe.
Calibration correct
Repeat calibration
or change probe
RECOMMENDED LEVEL: 6,8
RECOMMENDED LEVEL BETWEEN 7,2AND 7,5
RECOMMENDED LEVEL: MAXIMUM level according to model (see page2)
DISPLAY 1
DISPLAY 2
DISPLAY 3
DISPLAY 4
1
2
3
4
Calibration correct
Repeat calibration
or change probe

TROUBLESHOOTING
8
Display blank
*CheckOn/Offswitchisilluminated
*Checkexternal250mAfusehasnotfused.
*Checkelectricsupply:210-230V50Hz
*IfproblempersistscontactTECHNICALSERVICE
Electrolysis does not reach maximum intensity
*Checksodiumbromideorcommonsaltconcentrationinwater.
*Checkcellstatus(maybeincrustedorcalcified).
*Cleanelectrodefollowinginstructionsinsection6.
*Cleanflowdetectorsituatedinthecellcasing.
*Check titanium cell is not worn (remember that the cell is guaranteed for 5000-6000
hours(approx.2-3yearsofSummerusage)- seetroubleshootingformoreinformation).
Polarity 1 reaches max. intensity but polarity 2 (Auto clean) does not
*IFSALTLEVELISCORRECT(4-6kg./m3) cellisreachingendoflife.Asofthismomentcheckintensityevery15-30days
*Whenpolarity2doesnotreach50%werecommendsubstitutingcellforanewoneif during the summer or maximum usageperiod.Ifthisshouldhappeninwinterchangebefore
thenextseason(summer).
Free chlorine levels don't reach 0,8ppm. First thing in the morning
*INCREASEFILTRATIONINTERVAL.
*INCREASEelectrolysislevel.
*Checklevelsofsodiumbromideorcommonsaltinthepool(6gr.NaCl/L).
*Checklevelofisocyanuricacidinpool(30-50ppm.)ONLYifusingCOMMONSALT.
*CheckreactiveagentsintestkitarenotTOOOLD.
*Hasthetemperatureoramountofusersrisen(see3.1/3.2seechapter“Watermaintenance”).
*pHisabove7,8andmustbeadjusted.
Electrolysis display shows LO
*Waterlacksconductivity(seesection3“waterpreparation”).
*Checkforincrustationsoncell.
*Seetroubleshooting“Hydrolysisdoesnotreachmaximumintensity”.
White flakes in pool
*Thishappensinexcessivelyhardunbalancedwaters.
*Balancethewaterandcheckthecell,proceedingtocleanitifnecessary.
Electrolysis display shows FL
*Checkflowdetectorcable.
*Cleanincrustationsofflowdetectorattopofcellcasing.
*Checksystemisfreeofair(Probemustbealwayssubmerged).
RUST on metallic components in pool
*Metallicelementslackstandardizedearthconnection.Contactanelectriciantosolve
problem.
*Rustedcomponentsarenotstainlesssteel:minimum304-recommended316.
EARTHING
All metallic components in the pool, such as lamps, ladders, heat exchangers, drains or similar elements within 3.00m. from pool (10feet) must be connected to an earth
below37Ohms.
WERECOMMENDHEATEXCHANGERSBEMADEOFTITANIUM.
CLEANINGFILTER
EnsureHIDROLIFEisNOTRUNNINGduringbackwash.
VERYIMPORTANT
REMEMBERthatthesystemneedssometimetoadapttoyourpoolandyouwillhavetoincreasechemicallevelsforthefirst5days.
WARNING
Keepchemicallevelsinpoolasinstructedinthismanual
SECURITY
Toavoidaccidentsthisproductshouldnotbehandledbychildrenunlesssupervisedbyanadult.Childrenshouldbesupervisedatalltimeswheninornearaspa,poolorJacuzzi.
HANDLINGANDDOSINGDANGEROUSCHEMICALS
Chemicalsshouldbehandledwithextremeprecaution.WhenpreparingACID,ALWAYSADDTHEACIDTOWATER,neveraddwatertoacid!!!VERYdangerousgassesmaybeproduced.
Excess chlorine in water
*Lowerelectrolysiscellintensity.
*If your system includesAUTOMATIC REDOX CONTROL check REDOX
SETPOINT.
*CheckREDOXprobeandcalibrateifnecessary.
Titanium cell incrusted in less than 1 month
*Veryhardwaterswithahigh pH and totalalkalinity (Balance water adjusting
pHandtotalalkalinity).
*Checktoensurethesystemautomaticallychangespolarity(LED'salternate
every300min.approx.).
*CONSULT with our technical service to consider ACCELERATING THE
polaritychange(Auto-cleaning)WARNING:acceleratingthepolaritychange
decreasesthecelllife(5000hours)proportionally.
This manual suits for next models
7
Table of contents
Popular Swimming Pool Filter manuals by other brands

Jacuzzi
Jacuzzi COMMANDER II JC5 Installation and operation manual

GRE
GRE AR720 Installation and maintenance manual

Hayward
Hayward SwimClear owner's manual

SMC Networks
SMC Networks SMC20TA-2500 PPM instruction manual

Pentair Pool Products
Pentair Pool Products Filter CFW Series owner's manual

EINHELL
EINHELL SF 1000 operating instructions

Hayward
Hayward EZ-CHEM owner's manual

Procopi
Procopi Aquareva RTM SIDE S-610-A Instructions for installation and use

Hayward
Hayward OmniPL HLXPROUPG installation manual

ACIS
ACIS weltico A600 ELEGANCE Assembly instructions

Regal
Regal SMARTVALVES Instruction bulletin

XtremepowerUS
XtremepowerUS 90151 Owner's manual and safety instructions