Sun Power PVS6 User manual

•
•
•
•
•
•
•
Safety Instructions
Safety & Certications
NOTE:
•
•
•
IMPORTANT NOTES:
Radiation Exposure Statement
CAUTION:
FCC Compliance
•
•
Safety Certication
1. Mount the PVS6
2. Wire the PVS6 power
Danger! Hazardous voltages! Do not power up the system until after you
complete Sections 1 through 3.
°
•
•
•
Note:
L1
L2NGND
3. Install and wire the consumption CTs
Danger! Hazardous voltages! Do not power up the system until after you
complete Sections 1 through 3.
Refer to the Consumption Meter CT Installation Instructions.
THIS SIDE TOWARD SOURCE toward the utility meter and away from the
loads.
•L1 CT
•L2 CT
• Running CT wires:
• Extending CT leads:
Note: Continental Control Systems: Current Transformer (CT) Wire Extension
L1 CT and L2 CT CONS L1 and CONS L2
Caution!
4. Verify CT voltage phases
• 0V
•
5. Connect the system communication
Warning!
• AC modules
• SMA US-22 inverter: RS-
485 2-WIRE
• SMA US-40 inverter: LAN1
6. Connect the PVS6 to the internet
• Ethernet cable:(recommended method)
• Customer’s Wi-Fi network:
7. Commission with the PVS Management App
• AC module or SMA US-22: LAN 1
• SMA US-40 inverter: (A or B) in
Routing wire and cable:
• Fill all openings in the enclosure with components
rated NEMA Type 4 or better to maintain the integrity
of the enclosure’s environmental system.
•do not
•
•
•
•
Kit includes:
•
•
•
•
•
You will need:
•
•
•
•
•
•
•
•
•
PVS6 Installation Instructions
See the Equinox Installation Guide (#518101) for the
complete Equinox system installation instructions.
Intended Use:
–
Input
−OR
−
If the equipment is used in a manner not specied by SunPower, the protection provided by the equipment may be impaired.
Environmental Ratings
−°°

L2
L1
CT CT
3. Wire PVS6 power
°
Install a
4. Install consumption CTs
Refer to Section 3 on the other side for complete CT installation instructions.
6. Replace PVS6 wiring covers
5. Wire consumption CTs
7. Connect DC inverter communication
Never run
communication cable and
AC wiring in same conduit
SMA US-40
Inverter
SMA US-22
Inverter
2
7
10. Replace PVS6 cover
8. Connect PVS6 to the internet
Customer’s Wi-Fi
Ethernet Cable
6
9. Commission with PVS Management App
https://www.sunpowerconsole.com
PVS6 Quick Start Guide
Refer to the PVS6 Installation
Instructions on the other side for the complete instructions.
CT
CT
Main Service Panel
PVS6 Connection Diagram: DC Inverter Site
\
DC Inverter
Wire PVS6 power and CTs into
main service panel
Wire communication
from PVS6 to inverter
Wire PVS6 into AC
module subpanel
Wire CTs into main
service panel
AC Module Subpanel
CT
CT
Main Service Panel
PVS6 Connection Diagram: AC Module Site
AC Module Array
From CTs around
service conductors
Load-Side System:
downstream of CTs
Line-Side System:
upstream of CTs
To PVS6
To 15 A or 20 A
dual-pole breaker
Routing wire and cable:
• Fill all conduit openings in the enclosure with
components rated NEMA Type 4 or better
to maintain the integrity of the enclosure’s
environmental system.
•
do not
•
•
•
Note:
Hazardous voltage
DANGER!
SUNPOWER
PVS6
SUNPOWER
PVS6
Remove lower cover rst
2. Remove all PVS6 covers
1. Mount the PVS6
•
•
•
•
•
•
•
•
•
Warning!