manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sundstrom
  6. •
  7. Security Sensor
  8. •
  9. Sundstrom SR540 User manual

Sundstrom SR540 User manual

Product Manual
Sundstrom SR540 Supplied Air Shield
For more information: 1300 287 935 / mail@burwell.com.au / www.burwell.com.au
Copyright 2017 Burwell Technologies
SR 540
BRUGSANVISNING • BRUKSANVISNING • GEBRAUCHSANLEITUNG
GEBRUIKSAANWIJZING • INSTRUCCIONES DE USO • KÄYTTÖOHJEET
INSTRUCTIONS FOR USE • INSTRUÇÕES DE USO • MODE D’EMPLOI
INSTRUKJA UŻYTKOWANIA • NAUDOJIMO INSTRUKCIJOS • NáVOD K
POUžITí ISTRUZIONI PER L’UZO • KASUTUSJUHEND • HASZNáLATI UTASíTáS
LIETOšANAS INSTRUKCIJAS • NAVODILA ZA UPORABO • ИнструкцИИ за
употреба• NáVOD NA POUžITIE • Οδηγίες χρηςης • KULLANIMTALİMATLARI
14
4.4.3 Για να αντικαταστήσετε το στοιχείο
στεγανοποίηση προσώπου
Το πλαστικό πλαίσιο του στοιχείου στεγανοποίησης προσώπου
διαθέτει αύλακα (Εικ. 14 ) μέσα στην οποία εφαρμόζει το
πλαίσιο της μονάδας του μετωπικού περιβλήματος διόπτευσης
(Εικ. 15). Το πλαίσιο ασφαλίζεται με τη βοήθεια δύο πείρων,
ένα σε κάθε άκρο, που εφαρμόζουν στις οπές της μονάδας του
μετωπικού περιβλήματος διόπτευσης. Τα άκρα του υφάσματος
του στοιχείου στεγανοποίησης προσώπου φέρουν άγκιστρα τα
οποία ασφαλίζουν στην εξάρτηση κεφαλής. Προχωρήστε ως
ακολούθως:
•Ελευθερώστε τα άγκιστρα από την εξάρτηση κεφαλής.
Εικ. 16.
•Ελευθερώστε το στοιχείο στεγανοποίησης προσώπου
τραβώντας το πλαίσιό του, ώστε να ελευθερωθούν
οι πείροι από τις οπές της μονάδας του μετωπικού
περιβλήματος διόπτευσης. Εικ. 17.
•Ελευθερώστε το στοιχείο στεγανοποίησης προσώπου.
•Περάστε το νέο στοιχείο στεγανοποίησης προσώπου
πάνω από τη φλάντζα της μονάδας του μετωπικού
περιβλήματος διόπτευσης, ώστε να ευθυγραμμίζονται
μεταξύ τους οι ενδείξεις κέντρων. Εικ. 18.
•Πιέστε το πλαίσιο του στοιχείου στεγανοποίησης
προσώπου προς τα κάτω, ώστε οι πείροι να
εφαρμόσουν μέσα στις οπές της μονάδας του
μετωπικού περιβλήματος διόπτευσης. Ο
χαρακτηριστικός ήχος “κλικ” υποδηλώνει ότι έχουν
ασφαλιστεί. Εικ. 19.
• Ασφαλίστεταάγκιστραστηνεξάρτησηκεφαλής
στο σημείο όπου ελευθερώνεται ο απορροφητικός
κεφαλόδεσμος. Εικ. 16.
4.4.4 Για να αντικαταστήσετε τον
απορροφητικό κεφαλόδεσο
Ο απορροφητικός κεφαλόδεσμος ασφαλίζεται στον ιμάντα
μετώπου με ταινία Velcro. Προχωρήστε ως ακολούθως:
•Ελευθερώστε τα άγκιστρα του στοιχείου στεγανοποίησης
προσώπου από την εξάρτηση κεφαλής. Εικ. 16.
•Αποσπάστε τον απορροφητικό κεφαλόδεσμο.
•Εφαρμόστε τη λωρίδα Velcro, ώστε η πτυχωτή πλευρά της
να είναι στραμμένη προς τον ιμάντα μετώπου και με το
ανάγλυφο προς τα πάνω.
•Ασφαλίστε τα άγκιστρα στην εξάρτηση κεφαλής στο
σημείο όπου σχηματίζεται άνοιγμα στον απορροφητικό
κεφαλόδεσμο. Εικ. 16.
5. Λίστα εξαρτηάτων
Εξάρτηα Κωδ. παραγγελία
Αναπνευστικός σωλήνας R06-0501
O-ring για αναπνευστικό σωλήνα R06-0202
Επίπεδο παρέμβυσμα στεγανοποίησης R06-0506
Σετ βαλβίδων R06-0505
Απορροφητικός κεφαλόδεσμος R06-0504
Στοιχείο στεγανοποίησης προσώπου. Εικ. 14 T06-0504
Κάλυμμα κεφαλής SR 543. Εικ. 20 T06-0505
Σετ μετωπικού περιβλήματος διόπτευσης, PC R06-0502
Σετ μετωπικού περιβλήματος διόπτευσης,
PETG T06-0502
Σετ αφαιρούμενων προστατευτικών T06-0501
Μαντιλάκια καθαρισμού SR 5226,
συσκευασία 50 τεμ. H09-0401
6. Εγκρίσει
•Το μοντέλο SR 540 σε συνδυασμό με τη μονάδα
ανεμιστήρα SR 500/SR 700 έχει εγκριθεί σύμφωνα με
το πρότυπο EN 12941:1998, κατηγορία TH3.
•Το μοντέλο SR 540 σε συνδυασμό με το προσάρτημα
πεπιεσμένου αέρα SR 507 και τον αναπνευστικό
σωλήνα SR 358 ή SR 359 έχει εγκριθεί σύμφωνα με το
πρότυπο EN 14594:2005, κατηγορία 3 B.
•Το μοντέλο SR 540 σε συνδυασμό με το προσάρτημα
πεπιεσμένου αέρα SR 507 και τον αναπνευστικό
σωλήνα SR 360 έχει εγκριθεί σύμφωνα με το πρότυπο
EN 14594:2005, κατηγορία 3 Α.
Το πιστοποιητικό έγκρισης τύπου ΕΚ έχει εκδοθεί από το
Διακοινωμένο Όργανο 0194.
Για τη διεύθυνση, ανατρέξτε στο πίσω εξώφυλλο.
Face shield SR 540
EN
1. General information
SR 540 together with the fan unit SR 500/SR 700 and
approved filters is included in the Sundström fan-assisted
respiratory protective device system conforming to EN 12941/
EN 12942:1998 and the Powered Air Purifying Respirator
(PAPR) system conforming to AS/NZS 1716:2012 (fig. 2). The
breathing hose must be connected to the fan unit equipped
with filters. The above-atmospheric pressure generated in the
head-top prevents particles and other pollutants from being
admitted into the breathing zone.
SR 540 can also be used together with compressed air attach-
ment SR 507 conforming to EN 14594:2005 (fig. 1).
This combination forms a breathing apparatus designed for
continuous air flow, for connection to a compressed air supply.
If you have any questions regarding the selection and main-
tenance of equipment, consult your work supervisor or get in
touch with the sales outlet. You can also contact the Sundström
Safety AB’s Technical Support department.
Use of a respirator must be part of a respirator y protection pro-
gram. For advice see EN 529:2005 or AS/NZS 1715:2009. The
guidance contained in these standards highlights important
aspects of a respiratory protective device program
but does not replace national or local regulations.
1.1 Applications
The equipments can be used as an alternative to filter respira-
tors in all situations in which these are recommended. This
applies particularly if the work is physically demanding, warm
or of long duration. When selecting the head-top, some of
the factors that should be taken into account are as follows:
• Types of pollutants
• Concentrations
• Work intensity
• Protection requirements in addition to respiratory protective
device.
The risk analysis should be carried by a person who has
suitable training and experience in the area.
1.2 Warnings/limitations
Warnings
The equipment must not be used
• if the surrounding air does not have normal ox ygen content,
• if the pollutants are unknown,
• in environments that are immediately dangerous to life and
health (IDLH),
• with oxygen or oxygen-enriched air,
• if you find it difficult to breathe,
Sundstrom SR540 Supplied Air Shield
2 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
15
• if you can smell or taste the pollutants,
• if you experience dizziness, nausea or other discomfort.
Limitations
• The equipment is not approved for use in an explosive
atmosphere.
• If the face seal is not firmly in contact with the face, the
pressure necessary for maintaining the correct protection
factor will not be established.
• If the user is exposed to very high work intensity, a partial
vacuum may occur in the device during the inhalation phase,
which may involve the risk of leakage into the head-top.
• The protection factor may be reduced if the equipment is
used in surroundings in which high wind speeds occur.
• The seal of the head-top against the face must be assured.
This may be difficult to achieve if the user has a beard or
sideboards.
• Be aware that the breathing hose might make a loop and
get caught up by something in your surrounding.
• Never lift or carry the equipment by the breathing hose.
2. Use
2.1 Unpacking
Check that the equipment is complete in accordance with the
packing list and has not been damaged in transit.
2.2 Packing list
• Face shield
• Breathing hose
• User instructions
• Cleaning tissue
2.3 Assembly
See also the user instructions for fan unit SR 500/SR 700 or
compressed air attachment SR 507 whichever is used.
Breathing hose
One end of the hose is provided with a flat gasket (Fig. 3a) and
the other with an O-ring (Fig. 3b). Connect the end with the
gasket to the face shield.
2.4 Putting the face shield on
See also the user instructions for fan unit SR 500/SR 700 or
compressed air attachment SR 507 whichever is used.
• Raise the visor and put the face shield on. Fig. 4.
• If necessary, adjust the head harness in height by lengthening
or shortening the strap for the top of the head. Fig. 5a.
• If necessary, adjust the circumference of the head harness
by means of the knob at the rear of the head harness. Fig.
5b.
• Lower the visor unit by pulling the face seal down under your
chin. A clicking sound indicates that the visor unit has been
lowered fully. Fig. 6.
• Insert a finger between your chin and the face seal and run
the finger along the contact surface of the face seal all the
way round to check that it fits well against the face. Fig. 7.
• Check that the breathing hose runs along your back and
that it is not twisted. Fig. 8.
2.5 Taking the hood off
See the user instructions for fan unit SR 500/SR 700 or
compressed air attachment SR 507 whichever is used.
3. Technical specification
Shelf life
The equipment has a shelf life of 5 years from the date of
manufacture.
Temperature range
• Storage temperature: from -20 °C to +40 °C at a relative
humidity below 90 %.
• Service temperature: from -10 °C to +55 °C at a relative
humidity below 90 %.
Visors CE/EN
• The PC visor has been tested to class B, high-speed
particles, in accordance with EN 166:2001.
• The PETG visor has been tested to class F, high-speed
particles, in accordance with EN 166:2001.
Visors AS/NZS
• The PC visor has been tested to AS/NZS 1337:1992, high
impact V
• The PETG has been tested to AS/NZS 1337:1992,
medium impact I.
Materials
Plastic parts are marked with the materail code and recycling
symbol.
Weight
Weight approx. 680 g.
4. Maintenance
The person who is responsible for cleaning and maintenance
of the equipment must have suitable training and be well
acquainted with work of this type.
4.1 Cleaning
Sundström cleaning tissues SR 5226 are recommended
for daily care. If the equipment is more heavily fouled, use a
soft brush or sponge moistened with a solution of water and
dishwashing detergent or the like. Rinse the equipment and
leave it to dry.
N.B. Never use a solvent for cleaning.
4.2 Storage
After cleaning, store the equipment in a dry and clean place
at room temperature. Store the face shield with the visor in
the fully raised or fully lowered position. Avoid exposing it to
direct sunlight.
4.3 Maintenance schedule
The schedule below represents the recommended minimum
requirement for maintenance routines in order to ensure that
the equipment will always be in functional condition.
Before use After use Annually
Visual inspection •••
Performance check •
•
Cleaning
• •
Change of O-ring breathing hose •
Change of gasket for breathing hose •
Change of exhalation membrane •
4.4 Spare parts
Always use genuine Sundström parts. Do not modify the
Sundstrom SR540 Supplied Air Shield
3 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
16
equipment. The use of non-genuine parts or modification of
the equipment may reduce the protective function and put at
risk the approvals received by the product.
4.4.1 To change the exhalation membrane
The exhalation membrane is mounted on a pin on the inside of
the valve cover. The cover must be changed at the same time
as the membrane. Proceed as follows:
• Snap off the valve cover from the valve seat. Fig. 9.
• Slip off the membrane.
• Press the new membrane onto the pin. Carefully check that
the membrane is in contact with the valve seat all round.
• Press the valve cover into place. A clicking sound indicates
that it is in place.
4.4.2 To change the visor
The visor has two fixing points, one of which is of over-centre
type and is used for tensioning the visor. The visor can be
changed without tools. Proceed as follows:
• Remove the closing panels by pushing them forward with
your thumb. Fig. 10.
• Release the visor by moving the lever of the over-centre lock
upwards through about 180 degrees. Fig. 11.
• Remove the visor.
• Remove the peel-offs from the new visor.
• Secure the new visor first to the fixed mounting and then to
the over-centre mounting.
• Tension the visor by moving the lever downwards as far as
it will go. Fig. 12.
• Check that the visor is firmly in contact with the visor opening
seal all round.
• Fit the closing panels by pushing them into place with your
fingers. A clicking sound indicates that they are in place. Fig.
13.
4.4.3 To change the face seal
The plastic frame of the face seal is provided with a groove (Fig.
14) into which the visor unit frame fits (Fig. 15). The frame is
locked in position by means of two pins - one at each end - that
fit into holes in the visor unit. The ends of the face seal fabric
are provided with hooks that are secured to the head harness.
Proceed as follows:
• Release the hooks from the head harness. Fig. 16.
• Release the face seal by pulling its frame so that its pins are
released from the visor unit holes. Fig. 17.
• Remove the face seal.
• Thread the new face seal over the visor unit flange, with the
centre markings in line with one another. Fig. 18.
• Press the face seal frame down so that the pins drop into
the visor unit holes. A clicking sound indicates that they are
in place. Fig. 19.
• Secure the hooks to the head harness in the place where
the sweatband is relieved. Fig. 16.
4.4.4 To change the sweatband
The sweatband is secured to the forehead strap by means of
Velcro tape. Proceed as follows:
• Release the face seal hooks from the head harness. Fig. 16.
• Pull the sweatband off.
• Fit the Velcro strip with the ruffled side towards the forehead
strap and with the relief upwards.
• Secure the hooks to the head harness where a relief has
been made in the sweatband. Fig. 16.
5. Parts list
Part Ordering No.
Breathing hose R06-0501
O-ring for breathing hose. Fig. 3b R06-0202
Flat gasket for hose. Fig. 3a R06-0506
Set of valves R06-0505
Sweatband R06-0504
Face seal. Fig. 14 T06-0504
Head cover SR 543. Fig. 20 T06-0505
Visor set, PC R06-0502
Visor set, PETG T06-0502
Peel-off set T06-0501
Cleaning tissues SR 5226, box of 50 H09-0401
6. Approvals
CE/EN
SR 540 in combination with fan unit SR 500/SR 700:
12941:1998, class TH3. SR 540 in combination with com-
pressed air attachment SR 507 and air hose SR 358 or SR
359: EN 14594:2005, class 3B. SR 540 in combination with
compressed air attachment SR 507 and air hose SR 360: EN
14594:2005, class 3A.
The EC type approval certificate has been issued by Notified
Body No. 0194. For address, see back-cover.
Australian StandardsMark
The face shield SR 540 are tested according to AS/NZS
1716:2012. The StandardsMark is issued under licence by
SAI Global Cer tification Ser vices Pty Limited Lic No. 766 (ACN
108 716 669) (“SAI Global”).
Sundstrom SR540 Supplied Air Shield
4 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
53
1 2
3
Sundstrom SR540 Supplied Air Shield
5 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
54
8
13
12
45
7
10
11
9
14
6
Sundstrom SR540 Supplied Air Shield
6 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
55
17 18
19 20
15 16
Sundstrom SR540 Supplied Air Shield
7 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au
L67-0510 Rev 10 20161011
Sundström Safety AB
SE-341 50 Lagan • Sweden
Tel: +46 10 484 87 00
info@srsafety.se • www.srsafety.com
The head-top SR 540 is manufactured within a quality
management system accepted by
Notified Body 0194: INSPEC International Ltd,
Certification Services, 56 Leslie Hough Way,
Salford, M6 6 AJ, England
Sundstrom SR540 Supplied Air Shield
8 of 8For more information / 1300 287 935 mail@burwell.com.au / www.burwell.com.au

Other manuals for SR540

3

Other Sundstrom Security Sensor manuals

Sundstrom SR  900 User manual

Sundstrom

Sundstrom SR 900 User manual

Sundstrom SR 540 EX User manual

Sundstrom

Sundstrom SR 540 EX User manual

Popular Security Sensor manuals by other brands

TimeLapse ATM100 user manual

TimeLapse

TimeLapse ATM100 user manual

Bosch 440 Series installation guide

Bosch

Bosch 440 Series installation guide

DELTA DORE DMDR TYXAL+ installation guide

DELTA DORE

DELTA DORE DMDR TYXAL+ installation guide

Pepperl+Fuchs CCB10-30GS55-N1-V1 instruction manual

Pepperl+Fuchs

Pepperl+Fuchs CCB10-30GS55-N1-V1 instruction manual

Beko METPOINT CID quick start guide

Beko

Beko METPOINT CID quick start guide

Abus FUWM50000 manual

Abus

Abus FUWM50000 manual

Raymarine Evolution EV-2 installation instructions

Raymarine

Raymarine Evolution EV-2 installation instructions

Innotech AIO-GLEIT-12 instruction manual

Innotech

Innotech AIO-GLEIT-12 instruction manual

BGB 33333-A instruction manual

BGB

BGB 33333-A instruction manual

Johnson Controls tyco Bentel Security BW-DTM installation instructions

Johnson Controls

Johnson Controls tyco Bentel Security BW-DTM installation instructions

Lince ZENITH GOLD 869 Series Installation, operation and maintenance manual

Lince

Lince ZENITH GOLD 869 Series Installation, operation and maintenance manual

Bircher Reglomat RK 31C-PWH operating instructions

Bircher Reglomat

Bircher Reglomat RK 31C-PWH operating instructions

APRVTIO ALD-200 quick start guide

APRVTIO

APRVTIO ALD-200 quick start guide

AJAX MotionProtect user manual

AJAX

AJAX MotionProtect user manual

ABB SMD-W3.1A manual

ABB

ABB SMD-W3.1A manual

Siemens AGB600 installation manual

Siemens

Siemens AGB600 installation manual

Microsensor MTMK5883 Operation manual

Microsensor

Microsensor MTMK5883 Operation manual

Eterna PIR110BK installation instructions

Eterna

Eterna PIR110BK installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.