Sunmeditec WISE User manual

WIRELESS DIGITAL
STETHOSCOPE
User’s Manual
Ver. 2.0
2020.04

01
02
03
05
06
07
04
Products and features 4
6
5
7
8
10
10
5
6
7
8
9
7
7
7
7
5
5
Preparation before use
Product Name and its Functions
How to use it with a computer
VPM3000W Intro screen description
VPM3000W Input information screen description
How to use stethoscope
· Preparation before use
· Warnings for product use
· How to keep and manage it
· Stethoscope
· Installation for VPM3000W
· Stethoscope program installation (USB Dongle)
· Power ON/OFF
· Mode selection (Bell, Diaphragm, Wide)
· Volume control
· Stethoscope sound hearing
· Battery recharging
Index.
Sunmeditec Co., Ltd, who thinks of only health and happiness for its customers, will approach
customers with the best products and rapid After-Sales Service.

· Description for 『Figure7_Spectogram, Enlarged Pulse,
Whole Pulse Window』
· Pulse enlargement, reduction
· Pulse editing
14
15
16
17
18
17
Index.
08
13
14
15
09
10
12
11
VPM3000W main screen description
Data import
FAQ for product
Product specification
Product specification & Warranty
VPM3000W result screen description
How to record stethoscope sound
How to manage Data
How to see VPM3000W pulse and spectrogram
· Device Connection
· Record dialogue function window
· Data export to "tsa" or wave file
11-12
13
14
16
18
19
20
21
22

User’s Manual
4
01. Product and Features
This product is 『Medical device』 which is registered KFDA (No. 11-716).
Our Wireless Digital Stethoscope makes it possible to analyze heart, lungs or intestines sounds
from a body and make a diagnosis through these data.
This stethoscope makes it possible to select 3 sound measurement modes (Bell, Diaphragm,
Wide) depending on the bandwidth.
This stethoscope is easy to use while making measurements on the body. Also, while this
stethoscope is connected USB dongle, you can easily monitor the progress by wireless connection.
This connection is effective at a five-meter distance, and because of its micro processor and filter,
the signal strength and reliability of the wireless connection is enhanced.
This stethoscope removes the inconvenience of battery replacement by equipping a built-in large
capacity secondary battery.
This stethoscope can be used for a long time(approximately 54 hours in continuous use) with a
single charge due to the low voltage and low power circuit design.
This stethoscope makes it possible to monitor and save stethoscope sounds through the
“VPM3000W” software. This software also makes it possible to analyze, replay and edit
stethoscope sounds by spectrogram, detect and display inaccurate data using LCR algorithm, and
input basic information for medical diagnostics (body temperature, blood pressure, pulse and
oxygen saturation level) conveniently.
This stethoscope is very good for usability and portability as it is designed for ergonomics.

5
02. Preparation before Use
Warnings for product use
Preparation before use
How to keep and manage it
· Make sure to stabilize the person and be measured in correct status before use.
· Check if the ear phones (or speakers) connection works well.
· Check if the volume is suitable for using the stethoscope.
· Check if the battery is recharged.
· Install “VPM3000W” software on the computer to be used.
· Check if the receiver is normally connected to the computer.
· When an abnormality is found in the equipment, stop using it and ask us to inspect it.
· If you disassemble, repair or modify this stethoscope at your own discretion,
it may cause malfunction, and that will make After-Sales Service unavailable.
· Do not use this stethoscope while recharging of the battery.
· Do not expose it to direct sunlight.
· Keep it in a dry place.
· Be careful not to be shocked, especially when it moves.
· Do not keep it where chemicals and gas are emitted.
· Terms of use : Temperature 0℃~+40℃, humidity under 30~70%.
· Storage condition : Temperature -10℃~+60℃, humidity under 90%.
※Notice : the program, VPM3000W may be changed without notification for improvement.

User’s Manual
6
03. Product Name and its Functions
Stethoscope
Power Button
· Power ON/OFF button
Power & BT LED Display
· Stethoscope & BT status display
Mode Display LED
· Bell, Diaphragm, Wide mode selection
Mode Select Button
· Bell, Diaphragm, Wide mode selection
Volume Button
· digital volume button
Earphone Jack
· a jack for connecting the earlhones
Sensor Collecting Sounds
· a placte for collecting stethoscope sounds
(microphone)
Battery Charge Port
· a port for connecting the external battery
Figure 1 - Transmitter

7
· After you check if the equipment works properly, set the volume you want by pushing "◁ ▷" button.
· Once the volume is set up, the previous value is memorized even when you restart it after turning off the power
(The volume is set up for 10 steps from +1 to +10).
· If you want to directly hear sounds from the stethoscope, then connect the earphones
to the jack and then you can hear the sounds.
· When you recharge the battery, connect the battery to the recharging port while the
transmitter is not in use.
04. How to Use Stethoscope
Power ON/OFF
· After checking if the equipment is running, whenever you push the " " one time, the selection mode is changed
in this order D →W →B →D, and the green light in LED display window moves to selection location.
· When you push the " " button one time, a green light is displayed
on LED Display, and at the same time, the power is turned on.
· If you had the " " button for 2 seconds, the LED green light which
was turn on will turn off, and at the same time, the power will be turned off.
· If a button is not pushed in 3 minutes after the power is turned on, it is
automatically turned off.
Mode selection (Bell, Diaphragm, Wide)
Volume control
Stethoscope sound hearing
Battery recharging

User’s Manual
8
05. How to use it with a computer
Installation for VPM3000W
Recommended installation environment for VPM3000W
· CPU: over 1.5GHz
· OS: Windows 7 or higher
· Memory: over 256MB
· Hard Disk: over 80GB
· Graphic Card: over 1280x960(Notebook over 1024*768), 24 bits for color
VPM3000W Installation
· Insert the VPM3000W USB memory into a computer.
· The program is installed automatically.
(Refer to "Figure 1- VPM3000 Installation Screen") for the install procedure. If the program is not executed
automatically, run setup.exe] directly.)
Figure 1 - VPM3000W Installation Screen

9
Set up for VPM3000W Sound Device
· In the case of the output device, the sound card inside the computer is set to 'speaker' by default and If the speaker is
not connected, the program does not run.
· If you can not hear the sound of the output device speaker, check as follows.
· When you connect the output terminal for the sound card to the speaker, you need to check if the sound device in
"VPM3000W' Main screen(Setup→Device selection) is the device which the computer provides.
· If the device is set up for another device, change sound cards for the computer and then push the ‘selected’ button.
Stethoscope program installation (USB Dongle)
· Connect the USB Dongle to the USB port of the computer.
· For window 10, a driver is automatically provided to start the connection.
(For window 7, install the ‘USB Dongle driver’ in Sunmeditec USB memory.)
· When the driver installation is complete, ‘Settings’→’Device’→Bluetooth or any device selection and execute
→sunmeditec selection(At this time, the stethoscope must be turned on.)

User’s Manual
10
06.
07.
VPM3000W Intro Screen Description
VPM3000W Input Info. Screen Description
Input Info
Enter new patients and existing patients
to retrieve information
Main Screen
Go to the next Screen (Main Screen)
Minimize Button
VPM3000W program screen to m1nim1ze.
Exit Button
VPM3000W program exit.
1
2
3
4
Input Info. for Patient Window
Input information for patient.
(Name, Personal identification number, Sex, Height, Weight, Body
temperature, Blood Pressure, Blood Sugar, Oxygen Saturation)
New Info
Patient information currently being created to initialize.
Previous Button
Move to the previous step.
Next Button
Move to the next step.
List/Search Window
To retrieve patient information is stored.
1
2
3
4
5
1
1 2
3
4
Figure 2 - Intro Screen
Figure 3 - Input Info. Screen
2 3 4
5

11
Menu
It consists of File(New file, Open, Export, Import, Patients data, Print, Exit), Signal Edit(Whole Pulse Enlargement,
Partial Pulse Enlargement, Selected Section Copy, Selected Section Cut, Paste, Paste it at the end, Testing Print),
Device selection(Output Device Connection) and Help(Help, Program info).
I, II Spectrogram Window
'I' displays spectrogram (frequency range) for a selected section.
'II' displays spectrogram (frequency range) for a selected section.
I, II Enlarged Pulse Window
'I' displays an enlarged pulse for selected sections.
'II' displays an enlarged pulse for selected sections.
I, II Whole Pulse Window
'I' displays the whole pulse window for recorded stethoscope sound.
'II' displays the whole pulse window for recorded stethoscope sound or data base(DB).
Record
It is used to re-enter the Input information for patient
1
2
3
4
5
Figure 4 - Main Screen
18
1
2
3
4
567 8 910 11 12 13 14 15 16 17
08. VPM 3000W Main Screen Description

User’s Manual
12
Play
It is used to play(start) stethoscope sounds.
Stop
It is used to stop replay.
Zoom In
It is used to expand for stethoscope sounds.
Zoom Out
It is used to reduce for stethoscope sounds.
Undo
It is used to cancel or edit for stethoscope sounds.
Redo
It is used to rerun or edit for stethoscope sounds.
Copy
It is used to copy in the Signal Edit.
Cut
It is used to cut in the Signal Edit.
Paste
It is used to paste in the Signal Edit.
Save
It saves recorded stethoscope sounds in a file
Previous
Move to the previous step.
Next
Move to the next step.
Calendar Button
It is used to search a last data, patients list, and sample
data base(DB).
6
7
8
9
10
11
12
13
14
15
16
17
18
Figure 4 - Main Screen
18
1
2
3
4
567 8 910 11 12 13 14 15 16 17

13
09. VPM3000W Result Screen Description
Figure 5 - Result Screen
1
5
2
3
4
Menu
It consists of File(New file, Open, Export, Import, Patients data,
Print, Exit) and Help(Help, Program info).
'I' Spectrogram Window
'I' displays spectrogram (frequency range) for a selected section.
'I' Partial Pulse Window
'I' displays partial pulse (time range) for a selected section.
Analysis Result Window
It displays the patient' s analysis result by patient information.
Note Window
Doctor writes about for patient condition with a diagnosis.
1
2
3
4
5
Home
Move to the Main Screen.
Save
It saves recorded stethoscope sounds in a file.
Previous
Move to the previous step.
Print
Analysis result of the patient and doctor's note
can be output.
6
7
8
9
6 7 8 9

User’s Manual
14
10. How to Record Stethoscope Sound
· Stethoscope power ON.
· Connect the USB Dongle to the USB port of the computer.
· For window 10, a driver is automatically provided to start the connection.
(For window 7, install the ‘USB Dongle driver’ in Sunmeditec USB memory.)
· When the driver installation is complete, ‘Settings’→’Device’→Bluetooth or any device selection and execute
→sunmeditec selection.
· Connect the speaker to the computer’s speaker terminal(Green).
· Double click the VPM3000W program icon on your computer to run.
· Enter the patient’s information and go to the main screen.
· Click the ‘Record’ button at the bottom of the main screen to pop up the recording window.
· When the recording window is displayed, the signal is automatically monitored and displayed.
· Click the ‘Record’ button at the bottom of the recording pop-up window to record.
· You can ‘Record’, ‘Stop’, and ‘OK’ by clicking. Data is displayed in ‘I’ area.
Device Connection

15
Record dialogue function window
Monitoring waveform
It is used to monitor for heart sound and lung sound.
Monitoring & Recording states
Green color: monitoring, red color : recording
LCR(Level Crossing Rate)
LCR is displayed depending on patients disease.
Time
The record or monitor time is shown currently.
‘Record’ Button
When recording a stethoscope sound, press the button to record.
‘Stop’ Button
Press the button to stop.
‘OK’ Button
After you are finished recording, push the "OK" button and then recorded data is displayed on the 'I' region.
"esc" Button
If you push the "esc" button, then recording is canceled and this window closes.
Recording waveform
It is displayed the recording heart and lung sound.
1
2
3
4
5
6
7
8
9
Figure 6 - Record Dialogue Window
1 2 3 4 95 6 7 8

User’s Manual
16
Frequency and size for spectrogram
Description for 『Figure7- Spectrogram, Enlarged Pulse, Whole Pulse Window』
It displays the frequency bandwidth vertically from O to 2000 Hz.
It displays the size of signal as dB line color.
60dB 70dB 80dB 90dB 100dB 110dB 120dB
It displays the starting time for replay selection section.
It displays the ending time for replay selection section.
It displays the scaling for replay selection section.
The horizontal axis represents variation for time, and recorded pulses appear every 10 seconds.
Recorded stethoscope sound can be checked by scrollbar continuously.
1
2
3
4
5
6
7
11. How to See VPM3000W Pulse and Spectrogram
Figure 7 - Spectrogram, Enlarged Pulse, Whole Pulse Window
6 7
3
1
2 4 5

17
If you put your mouse on the whole pulse window while the data are displayed in the whole pulse window of
VPM3000W and press the left button of the mouse, and drag the mouse up to a section you want to see, and adjust
the mouse wheel while you press "Ctrl ", the dragged section is enlarged or reduced.
You can edit the pulse data by cutting, copying and pasting the pulses in the whole pulse window of VPM3000W.
If you press the right button of the mouse after selecting a section you want to edit from the whole pulse window, 『Figure9
- Pulse edit popup menu』 appears. You can edit it by selecting activated functions.
Pulse enlargement, reduction
Pulse editing
· Cut and copy in the selected section
It cuts or copies the selected section from the whole pulse window.
· Paste
It selects the copied pulses and pastes them on the starting point of the section.
If the section is not automatically selected, it pastes it at the end.
· Paste it at the end
It pastes the copied pulse on the end of the whole pulse.
Figure 8 - Pulse Edit Menu Figure 9 - Pulse edit popup menu

User’s Manual
18
You can create separate directory using Menu, File→Export where you can export patient data.
("tsa" File includ e patient's information, whole pulse and sound in the VPM3000W program.
On the other hand, wave file could be heard the sound using general sound system.)
12. How to Manage Data
Figure 10 - Pop Up Window For Export
4 5 6 7 8 9 10
2
1
3
· Check the items you want to export in the list .
· Select a folder where the data will be transferred by pressing .
(It shows a folder path for the data to be transferred.)
· If you check , the original data will be preserved and the copies are transferred.
· If you check , overwriting, the data move while no data is left on the current window for export.
· If you select , every item is selected in the list
· If you check , then all selected data will be unchecked.
· If you select , Wave data will be transferred to a designated folder.
· If you push , the selected data will be transferred or copied to a designated folder.
· If you push , Cancel button, then export is canceled and this window closes.
Data Export to "tsa" or wave file
1
4
5
6
7
8
9
10
2
3

19
You can create separate directory using Menu, file→import where you can import patient data.
13. Data Import
Figure 11 - Import Pop Up Window
1
4 5 6 7 8
2
3
· Select the folder having data to be imported. If you select the folder, the data in list are displayed.
· If you check for preservation of original file, the data are copied when imported. And if you check all selection
, all data in the list are selected. And if you select , then all selected data are unselected.
· If you push import button, then the selected data from the designated folder are copied to a "VPM3000W"
program DATA folder.
· If you push , Cancel button, all progressing things will finish and you return to the main screen.
Data import
2
4
5 6
7
8
1

User’s Manual
20
14. FAQ for Product
Q: Does not the power turn on?
A: If the built in battery for stethoscope is discharged, connect the USB charging cable to the computer’s USB port to charge it.
Q: Is not the sound available in the earphones?
A: Check if the power of the stethoscope is turned on, and check if the earphone is properly connected to the
earphone jack of the stethoscope.
Q: Is not the sound coming out from the speaker?
A: Check if speaker is properly connected to the speaker jack.
『(Set up for VPM3000W Sound Device』
of Page 9 for more detail)
Q: Although the stethoscope sound is available, is not it recorded?
A: Check if the power of the stethoscope is turned on. And also check it the USB dongle is properly
connected to the computer's USB port.
Q: Cannot the computer recognize the device?
A: If the instruction "The device is not found, run the program again after connecting the device " then
separate the USB dongle from the USB port and wait for 10 seconds and reconnect it.
(If ''The device is not found" appears again, make a phone call to After-Sales Service center of Sunmeditec
Q: Can' t you recharge the battery?
A: Check if the battery is properly connected to the recharging port of the stethoscope.
If the built in battery for stethoscope is discharged, connect the USB charging cable to the computer's USB port to charge it.
Q: Has the Battery life become shorter?
A: When the wireless stethoscope is used after fully recharged in the stethoscope, it lasts approximately 54 hours.
This manual suits for next models
1
Table of contents
Popular Medical Equipment manuals by other brands

Maquet
Maquet FLOW-I Pocket guide

Ferno
Ferno Mobile Transporter 35A Series user manual

Drive DeVilbiss
Drive DeVilbiss sidhil Innov8 Instructions for use

MD Orthopaedics
MD Orthopaedics Mitchell Ponseti Ankle Foot Orthosis Instructions for use

SGS
SGS Household Oxygen Bar operating instructions

illumina
illumina NextSeq 550Dx Instrument Safety and Compliance Guide