1
Preface
Product Instruction
Dear Customer:
Thank you for choosing our products and trust in our company.
ST-1200 optical scanner is a device designed specifically for the
glasses store, lens template scanning contour, contour data
modification, profile data of power down storage, optical instrument
center.
Please read the instructions carefully and put it on the grinding
machine near to at any time.
In the specification of information does not have the nature of the
contract, without prior notice to modify the content has been strictly
check and ensure correct errors or omissions, but can hardly be avoided.
Security information
1. Safety symbols appear on the product and description
This warning, marking the meaning is: if the violation,
inappropriate operation of the machine, and the risk of
serious damage to the existence of life.
This symbol represents a forbidden (prohibitions),
prohibited content at or near the painting special symbol
This symbol shows the operation must be executed,
specifically in this painting symbol

2
2. The use of environmental products(please try to avoid
using the machine in the following hazardous
conditions)
A. Outside the specified temperature range B. Fiercely vibration
C.The sun(ST-1200 belongs to the optical instrument, please
selectthe darkroom)
D. Dust/Smoke E.Moist
3. Note the use of products
A. Don’t make the machine by the sudden shock;
B. Don’t hit the button, a touch button can be
normal operation;
C. Don’t rely on the machine, the machine will fall
may cause injury;
D.After a day of work, turn off the power, clean
the machine appearance;
E. Don’t make the machine by pesticides or other
volatile solvent, otherwise it will lead to the
shell or other parts of aging damage.
A. Prohibits the plug with wet hands, it may cause
electric shock;
B. Prohibit the use of no marked rated AC, or may cause
a fire or electric shock;
C. No machine and other large power electrical
products share a wiring board, which will cause
large rambe voltage fluctuations, which may cause
the machine fault, shall provide a separate
electrical outlet for machine;
D. The pot prohibit metal or water containers such as

3
bottles, cups, etc. on the machine, if the metal material
or the flow of liquid into the machine, may cause a fire
or electric shock;
E. Do not scratch, damage, change the power cable in
the power line, don’t put too much weight, pulling,
bending power cable, this may cause a fire or electric
shock;
F. Prohibit unauthorized disassembly, repair, modification
machine, pressure machine, heating part or sharp objects
will make people injured.
A. Ensure that the machine is well grounded, the external
power supply is connected to ground, the machine is not
properly grounded will cause a fire or electric shock;
B. If the machine broke down or damaged chassis, first cut
off the power switch, unplug the power plug from the
socket, and then contact the sales agents, this cause to use
the machine, may cause a fire or electric shock;
C. When pulling out the power plug, and should ensure that
the plug part and pulled up, pull the wire may snap or
make internal wires exposed, causing a fire or electric
shock;
D. The continuous use of the machine hand production
abnormal situation, such as smoke, smell, may cause fire
and electric shock, these cases should be immediately cut
off the power switch, unplug the power plug from the
socket, then contact the sales agents.

4
Contents
Preface...................................................................................................................1
Product Instruction................................................................................................1
Security information .............................................................................................1
1 Instruction of machine.....................................................................................5
1.1 Main parts(Indicate the name of major external components and graphic)
..............................................................................................................................5
2 Use ................................................................................................................6
2.1 Install...............................................................................................................6
2.1.1 Instrument installation..........................................................................6
2.2 Instrumenttation ..............................................................................................7
2.2.1 Main interface......................................................................................7
2.2.2 Scanning lens template.........................................................................8
2.2.3 Template date modification (special lens)..........................................10
2.2.4 Fix center............................................................................................12
2.2.5 Menu ...............................................................................................14
2.2.6 Size correction.................................................................................14
2.2.7 Calibration of center meter.................................................................15
3 Performance parameter .................................................................................17
4 Attachment list (packing parts)...................................................................17

5
1 Instruction of machine
1.1 Main parts(Indicate the name of major external
components and graphic)
Graphic illustration:
(1) Display(touch screen) (2) Suction cup holder
(3) Lens carrier (4) The rotary shaft of center meter
(5) Ground lead (6) USB rim(reserve)
(7) Communication port1(COM1)(8) Communication port 2(COM2)
(9) Power switch (10)Adapter plug
(1)
(2)
(3)
(4)
(6)
(5)
(7)
(8)
(10)
(9)

6
2 Use
2.1 Install
2.1.1 Instrument installation
Illustration:
A. Choose a fixed, rigid platform level, should ensure that
the platform is fixed, strong;
B. One end of a communication line to connect the scanner,
the other end is connected with the grinding machine;
C. The adapter plug to connect the scanner;
D. Figure 2-1,2-2。
Chart 2-1
Lens edger interface

7
Chart 2-2
2.2 Instrumenttation
2.2.1 Main interface
Chart 2-3
Scanner interface
Center
meter
The
Symmetry
Scanning
template
Right
half-pupillary
distance
Right
pupillary height
Bridge
Data
download1
Data
modification
Machining lens minimum
diameter
Left
half-pupillary
distance
Left
pupillary height
Data
download1
Menu

8
2.2.2 Scanning lens template
A. Click on the main interface button,enter the lens template
scanning interface;
B. Use of the focal length of the lens template for management;
C. Remove the lens in the lens carrier template, template, convex
concave upward downward.
D. Three points on the template and the Blue Cross horizontal line
overlap, as chart 2-4;
E. System automatically recognize the template contour, red graphics
appear after, press ;
F. The input frame from the nose, as shown in Fig.2-5;
G. Complete the nose is set, click on the interface to set the
pupil distance and pupil high figure as shown in Fig. 2-6,2-7.
Fig. 2-4
CCD
contrast
Confirmation
of scan
Return
1. The template of convex concave upward
downward.
2. Dot and blue cross horizontal line overlap

9
Notice:
1. Lens carrier must be kept clean and clean;
2. Scanning contour, the edge of the lens can not have any dust
and dirt.
Fig. 2-5
Bridge
input
Half-PD
input

10
Fig. 2-6
Fig. 2-7
2.2.3 Template date modification (special lens)
A. Click on the main interface button ,enter into data
modification interface;
HD
input

11
Caution:
The modification is completed, need to reset the
interpupillary distance(PD), (HD), nose high pupil
distance (DBL), to transfer data to the grinding machine.
Width
modification
Height
modification
Angle
rotation
Template
data save
Memory
data
search
Memory
data
Width and Height
modification
Half-height
modification
Angle
rotation

12
2.2.4 Fix center
A. Click on the main interface button , enter a fixed center
mode;
B. Suction cup holder;
C. Select the geometric center mode, the rotary swing arm, and the
Left or Right
eye
CCD
contrast
Geometric
center model
Optical center
mode
Note: suction cup direction,
concave point to the left

13
suction cup.
D. Take the lens.
Cautions: The default mode (two centering instrument geometric
center mode and optical center mode)
1 Geometric center mode (manual shift) lens edger
processing mode
2 Optical center mode (automatic shift center) lens edger
processing mode
3 When the optical center mode is selected, the data download of the
grinding machine needs to be reset the value of △X、△Y、DBL.

14
2.2.5 Menu
A. Click on the main interface button , enter into menu;
2.2.6 Size correction
A. Click menu interface button , enter into size correction
interface;
Size
calibration
Center meter
calibration
Language
calibration
Size
compensation
Memory data
export
Memory data
import

15
2.2.7 Calibration of center meter
A. Click menu interface button , enter the dimension
calibration interface;
B. Take the calibrating tools, into the suction cup holder, the rotating
center of the arm, under pressure;
1. Move calibrating board,
click + - button, adjust the
red circle and the calibrating
board overlap
2. Red circle and the school board coincide,
click save, system automatic correction.

16
C.Adjust the level, vertical red line and black line overlap, click the save button;
2 .Adjust the level of the red
line coincides with the black
line.
1. Adjust the vertical red
line and black line
overlap.
3.The level of preservation of red and
black vertical should be overlap,then
save.
Regulating
knob

17
3 Performance parameter
Exterior dimension: 217×232×413mm;
Measuring range: lens template L ≤70mm; W≤70mm;
Weight: 10Kg
Voltage: The power adapter
Input: AC100~240V (50~60Hz);
Output: DC19V/4.7A;
Electric power consumption: ≤50W
Working condition: 5℃~40℃
4 Attachment list (packing parts)
No.
Name
Qty
1
The power adapter
1
2
The calibration of size
1
3
RS232 Communication
line
1
4
Black mark pen
1
Table of contents