Introduction
This is the Supra Wireless TRACcess Interface (WTI)
Retrot Installation Instructions. Read these instructions
before replacing the bezel interface with the wireless
interface. If you do not mount the interface accurately, it
will not function properly. Supra will not be responsible for
replacing the interface if it is damaged or destroyed upon
removal.
Installation supplies provided
• Drill template
• Exterior WTI interface plate
• Twosetsoffour#8atheadscrews(twodifferent
screw lengths for the mounting plate)
• Four #8 × 5/16 in. pan-head screws and lock
washers(forelectronicsenclosure)
• Six#4×1/2in.atheadscrews
• Plastic weather cover assembly
CAUTION: The electronics in this package are
electrostatic sensitive devices. Before you install the
unit, discharge or use a grounding belt.
Installation tools required
• Drill
• Drill bits
• File
• Phillips screwdriver
• Level or punch
• Pen or pencil
P/N10103022P1•November2011
© 2011 UTC Fire & Security. All rights reserved.
Wireless TRACcess Interface (WTI) Retrot
Installation Instructions
Figure 1. Bezel interface and Wireless interface
Installation
To replace the bezel interface with the wireless interface
(refertoFigure2):
1. Remove the screws from the electronics enclosure lid
and then remove the lid.
2. Disconnect the wiring plugged in to the electronics
enclosure. Make careful notes of the connection pin-
outsastheexteriorWTIinterfaceretrotplatewillbe
reconnected similarly.
3. Remove the four screws that secure the electronics
enclosure to the interior plate and remove the
electronics enclosure.
4. Remove the four screws securing the old bezel
interface plate to the interior plate. Remove the old
interface plate.
5. Feedthefour-wireplugfromtheretrotplatethrough
the cabling hole in the door, and secure the interior
mountingplatetotheretrotplate(Figure2).Insert
and tighten screws through interior mounting plate. For
1-1/4to1-1/2in.(32to38mm)doors,use3/4in.(19
mm)screws.For1-1/2to2in.(32to51mm),use1-1/4
in.(38mm)screws.
Note: If the screw does not fully secure the plates
to the door when tightened, use a shorter screw. Do
not overtighten the long screw.
6. Feedthefour-wireplugfromtheretrotplate,andthe
two-wire cable from the lockset through the cabling
hole in the electronics enclosure. You will attach the
wires after securing the enclosure.
7. Usethefour#8×5/16in.(16mm)pan-headscrews
and lock washers to attach the electronics enclosure
to the interior mounting plate. Insert and tighten the
screws and lock washers securely.
8. Connect the two-wire cable and the four-wire plug
as they were previously connected in the electronics
enclosure.
9. Inspectandconrmthatthebatteriesintheelectronics
enclosure are properly inserted, connected to the
battery terminal connections and secured in the battery
holdercompartment.(Inthecaseof9Vcells,make
sure the wires point toward you as you secure them in
place and the battery connectors should point toward
the circuit board).
10. Perform an Install function with a valid TRACcess
eKEY. Refer to the TRACcess eKEY user instructions
for step by step operation.
11. Test the lock operation using the TRACcess eKEY.
Refer to the TRACcess eKEY user instructions for step
bystepoperation.Testthelockrstwiththedooropen
and then with the door shut to ensure the lock strike
catches the door frame.
12. When you test the lock with your key, the LED at the
topoftheinterfacewillashgreen,indicatingthedoor
may be opened. If the device is a TRAC-Station BT
programmed for TIMED mode, the light will remain
ashingforapreprogrammedperiodoftime,during
which the door may be opened. If the device is a
TRAC-Station BT programmed for LATCHED mode,
oncethelightashesgreen,thedoormaybeopened
until the lock is reset. If it is programmed for LATCHED
mode, be sure to reset the lock.
13. Once you have tested the lock, place the lid on the
back of the electronics enclosure and position the logo
directly over the battery pack. Insert the provided six
#4×1/2in.(13mm)atheadscrewsintothepredrilled
holes. Hand-tighten the upper right corner screw and
continue hand-tightening the remaining screws in a
clockwise order. Do not overtighten the screws, as
doing so may damage the electronics enclosure and
prevent the lid from being securely fastened.
14. Record the device serial number and location.
Battery removal/disposal
Replacing the interface is a good time to service the
batteries. The batteries should be periodically replaced.
Thisproductcontainseitherthree9-voltbatteries(TRAC-
LockBT)oreightAAbatteries(TRAC-StationBT).To
removethebatteries,dothefollowing:
1. Remove the lid from the electronics enclosure.
2. Pull the batteries out of the slots.
For proper recycling, dispose of all batteries as required by
local ordinances or regulations.
FCC
The device, Assy, Bezel, WTI,partnumber10102917G1,
complies with part 15 of the FCC rules. Operation is subject to
thefollowingconditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired operation.
Changesormodicationsnotexpresslyapprovedbytheparty
responsible for compliance could void the user’s authority to
operate the equipment.
2002/96/EC (WEEE directive). Products marked with this
symbol cannot be disposed of as unsorted municipal waste in
the European Union. For proper recycling, return this product
to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collection points.
Figure 2. TRAC-Station BT assembly as example
Supra:800-547-0252•www.suprasystems.com
Electronics
Enclosure
Exterior WTI
Interface
Plate
Interior
Mounting
Plate
Electronics
Enclosure Lid
Lockset
2-wire plug
4-wire
plug

This manual suits for next models

1

Other Supra Lock manuals

Supra ActiveKEY Installation guide

Supra

Supra ActiveKEY Installation guide

Supra iBox User manual

Supra

Supra iBox User manual

Supra TRAC-Guard Instruction Manual

Supra

Supra TRAC-Guard Instruction Manual

Supra TRAC-Guard Instruction Manual

Supra

Supra TRAC-Guard Instruction Manual

Popular Lock manuals by other brands

american lock A700 Assembly/disassembly manual

american lock

american lock A700 Assembly/disassembly manual

NEC N8140-819 Setup guide

NEC

NEC N8140-819 Setup guide

LOX LOCKING EM3500 installation manual

LOX LOCKING

LOX LOCKING EM3500 installation manual

Sylvan SL38E user manual

Sylvan

Sylvan SL38E user manual

Cal-Royal CRCODE-204 Instruction and programming manual

Cal-Royal

Cal-Royal CRCODE-204 Instruction and programming manual

Ojmar LOCKR 75 User and maintenance manual

Ojmar

Ojmar LOCKR 75 User and maintenance manual

Dorma EM Series quick guide

Dorma

Dorma EM Series quick guide

Schlage AD-200 instruction manual

Schlage

Schlage AD-200 instruction manual

Salto XS4 Original+ E i 450 Series installation guide

Salto

Salto XS4 Original+ E i 450 Series installation guide

Unitech UL110 manual

Unitech

Unitech UL110 manual

Kiramek SL20T manual

Kiramek

Kiramek SL20T manual

CDVI V3SR manual

CDVI

CDVI V3SR manual

Avia Smart Lock troubleshooting guide

Avia

Avia Smart Lock troubleshooting guide

KA Security KAS-820-DE user guide

KA Security

KA Security KAS-820-DE user guide

Knox FDC Plug operating instructions

Knox

Knox FDC Plug operating instructions

Yale Smart Latch 2 manual

Yale

Yale Smart Latch 2 manual

Vanderbilt V42 Technical manual

Vanderbilt

Vanderbilt V42 Technical manual

Kaba Mas X-09 operating instructions

Kaba Mas

Kaba Mas X-09 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.