suprema BioLite Net User manual

English
Version 2.00
BioLite Net
USER GUIDE
www.supremainc.com
EN 102.00.BLN V2.00

Contents
Safety Instructions ..........................................................................................4
Getting Started ................................................................................................6
Components ...................................................................................................................................................6
Part names and features .............................................................................................................................7
How to Scan a Fingerprint..........................................................................................................................8
Choosing a finger for registration .......................................................................................................8
How to register a fingerprint ...............................................................................................................8
User Management ...........................................................................................9
Registering User Information ......................................................................................................................9
Changing User Information .......................................................................................................................10
Changing or Adding a fingerprint .....................................................................................................10
Changing PIN.........................................................................................................................................10
Changing or Adding a card ................................................................................................................10
Changing authority...............................................................................................................................11
Deleting a User ...........................................................................................................................................11
Checking User Capacity Status .................................................................................................................11
Authentication Configuration ..................................................................... 12
Fingerprint Authentication configuration ................................................................................................12
Card Authentication configuration ...........................................................................................................12
ID Authentication configuration ...............................................................................................................12
Matching Timeout configuration ..............................................................................................................13
Scan Timeout configuration ......................................................................................................................13
Display/Sound Configuration...................................................................... 14
Backlight Timeout configuration ..............................................................................................................14
Menu Timeout configuration.....................................................................................................................14
Message Timeout configuration................................................................................................................14
Language selection.....................................................................................................................................14
Sound configuration ...................................................................................................................................14
Device Configuration ................................................................................... 15
Checking Device Information ....................................................................................................................15
Date/Time configuration.............................................................................................................................15
Fingerprint configuration...........................................................................................................................15
Template Type configuration...............................................................................................................15
Security Level configuration................................................................................................................15
Authentication Speed (Fast Mode) configuration ............................................................................16
Sensitivity configuration ......................................................................................................................16
Communication Configuration.................................................................... 16
TCP/IP configuration ...................................................................................................................................16
Server IP configuration ........................................................................................................................16
Device IP configuration........................................................................................................................16
RS-485 configuration ..................................................................................................................................16
RS-485 Mode configuration.................................................................................................................16
Baud Rate configuration ......................................................................................................................17
Termination configuration....................................................................................................................17
Device Reset .................................................................................................. 17
Full Reset .....................................................................................................................................................17
2

Reset Without Net ......................................................................................................................................17
Reboot ..........................................................................................................................................................17
Troubleshooting ............................................................................................ 18
Checklist before Requesting Service........................................................................................................18
Product Specifications ................................................................................. 19
Product Specifications ................................................................................................................................19
Dimensions...................................................................................................................................................20
FCC Compliance Information...................................................................... 21
Appendix ........................................................................................................ 22
Disclaimers ...................................................................................................................................................22
Copyright Notice .........................................................................................................................................22
3

Safety Instructions
Please read the following instructions carefully before using the product. This information is important for ensuring the safety of the user and
for preventing damage to the user's property.
Warning
Violation of the instructions may cause serious injury or death.
Installation Instructions
Do not install the product in direct sunlight or in a location that is damp or dusty.
•This can cause a fire or electric shock.
Do not install the product near any heat source such as electric heaters.
•This can cause a fire from overheat or electric shock.
Install the product in a dry place.
•Moisture can cause product damage or electric shock.
Install the product in a place where there is no electromagnetic interference.
•This can cause product damage or electric shock.
Have qualified service professionals install or repair the product.
•Otherwise, it can cause a fire, electric shock, or injury.
•If the product is damaged due to a user's unauthorized installation or dismantling of the product, a service fee will be charged for repair.
Operating Instructions
Be careful not to spill any liquid such as water, drinks, or chemicals inside the product.
•This can cause fire, electric shock, or product damage.
Caution
Ignoring these instructions may result in minor injuries or damage to the product.
Installation Instructions
Protect the power cord from being walked on or pinched.
•This can cause product damage or injury.
Keep the product away from strong magnetic objects such as magnets, TVs, monitors (especially CRT monitors), or speakers.
•This can cause a failure.
Only use the power adapter included with the product or a DC power adapter providing a current more than 500mA.
•This device does not work if the proper power source is not used.
Secure I/O 2, the electrical locking device and this product must use independent power source.

Safety Instructions
Operating Instructions
Do not drop the product or subject it to shock or impact during use.
•This can cause a failure.
Keep the password secret from others and change it periodically.
•Failure to do so may lead to an illegal intrusion.
Do not press the buttons on the product with excessive force or with a sharp tool.
•This can cause a failure.
Be careful not to contaminate or damage the fingerprint reader with a dirty hand or materials.
•This can decrease performance or cause failure to read a fingerprint.
Clean the product with a soft, dry cloth. Do not use alcohol, benzene, or water.
•This can cause a product failure.
5

Getting Started
Getting Started
Components
•The components may differ depending on where the product is installed.
•For more information about installation, visit www.supremainc.com.
BioLite Net
Main bracket
Extension bracket
Mounting screws
(2 pcs)
Screw anchors
(2 pcs)
Heat shrink tubes
Ethernet connector
Hex wrench
(for mounting bracket)
Diode
(1 pc)
Adapter
Note
6

Getting Started
Part names and features
Name Feature
LCD screen Displays various information or settings.
Keypad
•0–9 buttons: For entering an ID or password.
•< > direction button: Navigates to an item. When entering numbers or an IP address, the < button can be
used to delete the value entered.
•button: Chooses a function.
•button: Enters or exits a menu.
•button: Moves back to the previous screen or cancels an input.
LED lamp
Shows the status of the product with different colors and beeps.
•Green: Authentication success.
•Red: Authentication failure.
•Pink: Processing.
•Blue and yellow alternate flashing every 2 seconds: The IP address has not been received via DHCP in
Device IP configuration.
•Blue and sky-blue alternate flashing every 2 seconds: Normal operation.
•Red and pink alternative flashing every 2 seconds: The device is locked or no administrator.
•Blue and red alternate flashing every 2 seconds: The clock has been reset due to an empty internal battery.
(The clock needs to be reconfigured.)
•Red flashes every 2 seconds on first use: Failure to reset. Contact the manufacturer.
•Yellow flashes briefly: Waiting for an input.
Fingerprint reader Reads fingerprints placed on it for entering and exiting.
RF card touch area Reads RF cards for entering and exiting.
LED lamp
Fingerprint reader
RF card touch area
LCD screen
Keypad
7

Getting Started
How to Scan a Fingerprint
Register a fingerprint correctly to improve the recognition rate of the fingerprint. BioLite Net can read a fingerprint even when the angle or
position of the finger has changed. If you register a fingerprint with the following instructions, the recognition rate can be improved.
Choosing a finger for registration
•Each person can register up to 10 fingerprints. If some fingers were injured or used to carry
something, they should not be used.
•If a fingerprint is not well scanned, the fingerprint can be registered twice, which improves the
recognition rate.
•If a finger is injured or the fingerprint is not clear, please use another finger for registering.
•The index finger or middle finger is preferred for registering a fingerprint. The other fingers may
show a lower recognition rate because those fingers tend to have difficulty being placed at the
center of the fingerprint reader.
How to register a fingerprint
1
When“Scan 1st finger” message appears on the LCD screen for the fingerprint registration, place a finger on the fingerprint recognition
area and then press softly in order to improve the recognition.
2
After a beep sounds and a screen appears to scan again, scan the finger again.
(The finger should be scanned twice for registering.)
Precautions for registering a fingerprint
Registering a finger is the most important procedure because this device uses the registered fingerprint to compare it with a fingerprint that the device
tries to read. Please ensure the following when registering a fingerprint:
•Place a finger firmly on the fingerprint reader for it to be read completely.
•The center of the fingerprint should be placed at the center of the fingerprint reader.
•If a finger is injured or the fingerprint is not clear, please use another finger for registering.
•Follow the instructions on the screen and place the finger correctly without movement when a finger is read.
•If the finger is lifted up, not placed at the center, or only part of the finger is placed on the fingerprint reader, the fingerprint may not register.
Precautions for reading a fingerprint
BioLite Net can read fingerprints regardless of the change in seasons or condition of the fingers. However, the external environment or the finger's
placement can affect the recognition rate.
If a fingerprint is not well read, the following actions are recommended.
•If there is water or sweat on the finger, please wipe it off before placing the finger.
•If the finger is too dry, please blow softly on the fingertip before placing the finger.
•If the finger is injured, please register another finger.
•The fingerprint that is registered on the first attempt tends to be placed incorrectly. So, register a fingerprint multiple times according to ‘Precautions
for registering a fingerprint’.
Note
8

User Management
User Management
Registering User Information
User information including fingerprints can be registered.
•User information cannot be registered if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Add User, and then press OK button.
3Enter the ID of the user to be registered, and then Press OK button.
•The ID can be a number of 1–4294967294.
4Select the number of fingerprints of the user to be registered, and then press OK button. After scanning the fingerprint of the registered
finger, the same finger should be scanned one more time.
•If the number of fingerprints is set to 0, the user cannot use a fingerprint for authentication.
5Select the number of cards to be registered, and then press OK button. Scan the card that will be assigned to the user.
•If the number of cards is set to 0, the user cannot use a card for authentication.
6Select User Level, and then press OK button.
•Normal: indicates the level of normal users who cannot use the configuration menu.
•User Mgmt: can register or change the user information.
•Configuration: can change the configurations such as screen/sound, device, or communication.
•Administrator: can use every configuration menu.
7Enter a PIN, and then press OK button. Enter the PIN again for confirmation, and then press OK button.
•To prevent the unauthorized user from the menu, you must register the Administrator.
•Keep the ID in a separate place after writing down because it will be used for changing or deleting user information.
•More than two fingerprints per user ID can be registered in order to improve the fingerprint recognition rate.
•Enter a number of 4–16 digits to prevent leaking of the PIN.
Note
Note
9

User Management
Changing User Information
User administrator or Super administrator can change the information of a registered user. They can add the fingerprints or card of the user,
and also change PIN or authority.
•User information cannot be changed if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
Changing or Adding a fingerprint
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Edit User, and then press OK button.
3Enter the ID of the user to be changed, and then press OK button.
4Select Fingerprint, and then press OK button.
5Select the fingerprint number to be changed or New, and then press OK button.
6After scanning a fingerprint, the same finger should be scanned one more time.
Changing PIN
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Edit User, and then press OK button.
3Enter the ID of the user to be changed, and then press OK button.
4Select PIN, and then press OK button.
5Enter a new PIN, and then press OK button.
6Enter the PIN again for confirmation, and then press OK button.
•Enter a number of 4–16 digits to prevent leaking of the PIN.
Changing or Adding a card
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Edit User, and then press OK button.
3Enter the ID of the user to be changed, and then press OK button.
4Select Card, and then press OK button.
5Select the card number to be changed or added, and then press OK button.
6Scan a card.
Note
Note
10

User Management
Changing authority
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Edit User, and then press OK button.
3Enter the ID of the user to be changed, and then press OK button.
4Select User Level, and then press OK button.
5Select a new authority, and then press OK button.
•Normal: cannot use every menu.
•User Mgmt: can use only User menu.
•Configuration: can use every menu except User menu.
•Administrator: can use every menu.
Deleting a User
A registered user can be deleted.
•User information cannot be deleted if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the communication
mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > Delete User, and then press OK button.
3Enter the ID of the user to be deleted, and the press OK button.
4Press OK button to confirm the deletion.
•The deleted user cannot be restored. If necessary, the user should be registered as a new user.
•Use User > Delete all users menu in order to delete all users.
Checking User Capacity Status
The information including the number of registered users, fingerprints, or cards can be looked up.
•User registration status cannot be looked up if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select User > User Capacity, and then press OK button.
3The capacity status will appear.
Note
Note
Note
11

Authentication Configuration
Authentication Configuration
Fingerprint Authentication configuration
A schedule can be configured for each authentication method using fingerprints.
•Fingerprint authentication mode cannot be configured if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change
the communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Authentication > Finger, and then press OK button.
3Select the authentication mode that you want, press OK button.
•Fingerprint: This mode uses only a fingerprint.
•Finger+PIN: After recognizing a fingerprint, a PIN should be entered.
4Select a schedule to be used, and then press OK button.
•A new schedule can be registered in BioStar. Refer to BioStar administrator manual for details.
Card Authentication configuration
A schedule can be configured for each authentication method using cards.
•Card authentication mode cannot be configured if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Authentication > Card, and then press OK button.
3Select the authentication mode that you want, press OK button.
•Card: This mode uses only a card.
•Card+Finger: After authenticating a card, a fingerprint should be recognized.
•Card+PIN: After authenticating a card, a PIN should be entered.
•Card+Finger/PIN: After authenticating a card, either a fingerprint should be recognized or a PIN should be entered.
•Card+Finger+PIN: After authenticating a card, both the fingerprint recognition and the PIN entering are needed.
4Select a schedule to be used, and then press OK button.
•A new schedule can be registered in BioStar. Refer to BioStar administrator manual for details.
ID Authentication configuration
A schedule can be configured for each authentication method using IDs.
•ID authentication mode cannot be configured if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Authentication > ID, and then press OK button.
3Select the authentication mode that you want, press OK button.
Note
Note
Note
Note
Note
12

Authentication Configuration
•ID+Finger: After entering an ID, a fingerprint should be recognized.
•ID+PIN: After entering an ID, a PIN should be entered.
•ID+Finger/PIN: After entering an ID, either a fingerprint should be recognized or a PIN should be entered.
•ID+Finger+PIN: After entering an ID, both the fingerprint recognition and the PIN entering are needed.
4Select a schedule to be used, and then press OK button.
•A new schedule can be registered in BioStar. Refer to BioStar administrator manual for details.
Matching Timeout configuration
For the server matching, a timeout can be configured. If the server matching is not completed within the configured time, the authentication
fails.
•The time for Server matching cannot be configured if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change
the communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Authentication > Matching Timeout, and then press OK button.
3Select the time that you want, and then press OK button.
Scan Timeout configuration
For the user authentication, a timeout can be configured. If the user authentication is not completed within the configured time, the
authentication fails.
•Authentication time cannot be configured if RS-485 Mode is set to Slave. Refer to RS-485 Mode configuration in order to change the
communication mode.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Authentication > Scan Timeout, and then press OK button.
3Select the time that you want, and then press OK button.
Note
Note
Note
13

Display/Sound Configuration
Display/Sound Configuration
Backlight Timeout configuration
The time to turn off the light of LCD screen can be configured.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Display/Sound > Backlight Timeout, and then press OK button.
3Select the time that you want, and then press OK button.
Menu Timeout configuration
The time to make the menu screen disappear can be configured. If there is no button input within the configured time, the display is changed
to the Home screen.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Display/Sound > Menu Timeout, and then press OK button.
3Select the time that you want, and then press OK button.
Message Timeout configuration
The time for the configuration completion message or notification message to disappear automatically can be configured.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Display/Sound > Msg Timeout, and then press OK button.
3Select the time that you want, and then press OK button.
•If RS-485 Mode is set to Slave, slave device operates according to timeout setting of master device. Refer to RS-485 Mode configuration in
order to change the communication mode.
Language selection
The system language can be configured.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Display/Sound > Language, and then press OK button.
3Select the language that you want, and then press OK button.
Sound configuration
The sound can be turned on or off by configuration.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Display/Sound > Sound, and then press OK button.
3Choose whether the sound is on or off, and then OK button.
Note
14

Device Configuration
Device Configuration
Checking Device Information
Device ID, F/W version, or MAC address can be displayed.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Device Info, and then press OK button.
3Direction buttons can be used to navigate the screen to find out the device information.
4Press ESC button to get back the previous screen.
Date/Time configuration
Current date and time can be configured. Date and time should be configured to get the correct log data.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Date/Time, and then press OK button.
3Enter the current date in the requested format, and then press OK button.
•For example, the date of November 15th, 2014 is entered by pressing‘20141115’at the keypad.
4Enter the current time in the requested format, and then press OK button.
•For example, the time of 5:20PM is entered by pressing‘172055’at the keypad.
Fingerprint configuration
Template Type configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Fingerprint > Template Type, and then press OK button.
3Select the fingerprint template type that you want, and then press OK button.
•SUPREMA / ISO 19794-2 / ANSI-378
•After deleting all the user fingerprint information, change the template type. If there is any user fingerprint information, the template type cannot be
changed.
Security Level configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Fingerprint > Security Level, and then press OK button.
3Select the security level that you want, and then press OK button.
•Normal / Secure / Most Secure
•As the security level becomes higher, the recognition fail rate may increase.
Note
Note
15

Communication Configuration
Authentication Speed (Fast Mode) configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Fingerprint > FastMode, and then press OK button.
3Select the authentication speed that you want, and then press OK button.
•Auto / Normal / Fast / Fastest
Sensitivity configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Fingerprint > Sensitivity, and then press OK button.
3Select the sensitivity that you want, and then press OK button.
•The sensitivity can be set in the range of 1–7, and as the value becomes larger, the fingerprint sensor operates more sensitively.
Communication Configuration
TCP/IP configuration
Server IP configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Communication > IP Address > Server IP, and then press OK button.
3Select whether to use server.
4If set Server Discovery to Enabled, entering IP address and port, and then press OK button.
•When entering IP, a period (.) can be entered by pressing the > button on the keypad.
Device IP configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Communication > IP Address > Device IP, and then press OK button.
3In order to use a dynamic IP, set DHCP to Enabled, and then press OK button.
4In order to set the IP value directly, set DHCP to Disabled. After entering Device IP, Gateway, Subnet mask, and Device Port, press
OK button.
•When entering IP, a period (.) can be entered by pressing the > button on the keypad.
RS-485 configuration
RS-485 Mode configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Communication > RS485 > RS-485 Mode, and then press OK button.
3Select the communication mode that you want, and then press OK button.
Note
Note
16

Device Reset
Baud Rate configuration
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Communication > RS485 > Baud Rate, and then press OK button.
3Select the baud rate that you want, and then press OK button.
Termination configuration
1Press MENU button, and then get authenticated with the administrator authority authentication method.
2Select Communication > RS485 > Termination, and then press OK button.
3Select whether the termination is used or not, and then press OK button.
•If a connection wire is too long when connecting by RS-485, this can be used to enhance the signal strength.
Device Reset
Full Reset
All user information and configuration information are initialized.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Device Reset > Full Reset, and then press OK button.
3In order to conduct the initialization, press OK button.
Reset Without Net
The communication configurations such as Server IP or RS-485 configuration are not initialized.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Device Reset > Config+IP Reset, and then press OK button.
3In order to conduct the initialization, press OK button.
Reboot
The device can reboot.
1Press the MENU button, and then authenticate with the administrator authentication method.
2Select Device > Device Reset > Reboot, and then press OK button.
17

Troubleshooting
Troubleshooting
Checklist before Requesting Service
Category Problem Solution
Power Power is supplied to the device,
but the device does not work.
•If the terminal is apart from the bracket, it may not work due to the tamper
switch.
•Check the adapter or power connection cable.
PIN
I've lost my PIN. •For a normal user's PIN, contact your administrator and then enter PIN again.
•If an administration's PIN is lost, contact your installer.
I cannot open a locked door
when I enter a PIN and then
press the OK button.
•Check whether the registered PIN is entered correctly.
•Check whether PIN has recently been changed.
•If you cannot find the PIN, ask an administrator to enter PIN again.
Fingerprint
sensor
A fingerprint is registered
successfully, but it is not well
recognized and suffers a lot of
errors.
•
Refer to‘
How to Register a fingerprint
’, and then register the fingerprint again.
•Since there would be a variation of recognition rate due to the different
characteristics of each fingerprint, please try to register another fingerprint.
The fingerprint recognition does
not work.
•Check whether the finger or the fingerprint sensor has sweat, water, or dust on
it, and then wipe it clear.
•If a finger is injured, the finger may be recognized as another person's finger.
•Try again after clearing the finger and the fingerprint sensor with a dry cloth.
•If the finger is too dry, try again after blowing gently on the finger.
Door lock The locking device does not
work when the door is closed.
•The electrical locking device may have a problem. Ask your installer to get it
examined.
Time The time displayed is not correct.
•Even though BioLite Net includes an internal battery, the time could become
incorrect due to the discharge of the internal battery if power has not been
applied to the system for a long time. Refer to Date/Time configuration in
order to adjust the time.
Administrator
Connection
The administrator mode cannot
be accessed due to the loss of
administrator PIN or the
resignation of the administrator.
•Since in BioLite Net administrators are in charge of permitting the right of
entrance, only the administrators can access the menu.
•If it is inevitable to access the administrator menu, it is possible to get a PIN
issued in accordance with the predefined procedure. Ask your installer about
the procedure to issue a password.
18

Product Specifications
Product Specifications
Product Specifications
Category Feature Specification
Main
Biometric Fingerprint
IP Rating IP 65
RF Card 125KHz EM, 13.56MHz Mifare/DESFire
Multi-Controller Yes
Capacity
Max. User (1:1) 5,000
Max. User (1:N) 5,000
Max. Template (1:1) 10,000
Max. Template (1:N) 10,000
Max. Text Log 50,000
Interface
TCP/IP Yes
RS-485 1ch Host or Slave (Selectable)
Wiegand 1ch In or Out (Selectable)
TTL Input 2 Inputs
Relay 1 Relay
Relay
Voltage Max. 24VDC
Current Typ. 0.5A, Max. 1.0A
Hardware
CPU 533MHz DSP
Memory 16MB RAM + 8GB Flash
LCD 128 x 64 Graphic LCD (Mono)
LED Multi-Color
Sound Multi-tone Buzzer
Operating Temp. -20°C ~ 50°C
Tamper Yes
Power 12VDC
Dimensions (W x H x D mm) 60 x 185 x 40
Certification CE, FCC, MSIP(KCC), RoHS
19

Product Specifications
Dimensions
Main bracketExtension bracket
Diameter 4.5
Diameter 4.5
Diameter 3.5
20
Other manuals for BioLite Net
3
Table of contents
Other suprema Gateway manuals
Popular Gateway manuals by other brands

RTA
RTA 460ECDFM-N700 Product user guide

Zenitel
Zenitel ICX 500 Mounting & installation

Rosemount
Rosemount 1420 quick start guide

Gemtek
Gemtek GIoT Femto WLRGFM-100 user guide

SolarEdge
SolarEdge Home Gateway installation guide

Mennekes
Mennekes eMobility-Gateway Professional+ OPERATING AND INSTALLATION Manual