Surecom SW-102HF User manual

Key Specifications/Special Features:
Measurement S.W.R.
Measurement RF Power watt (FF / REV)
Battery Level display
Blacklight LCD display
Use time
Specifications:
Max Power:
120W
VSWR:
1.00:1~19.99 :1
Frequency Range:
Cover:1.5MHz-70MHz
Power in:
5V (micro usb)
Li-ion Battery :
3.7V Li-ion Battery
In /Out Impedance : 50 Ω
Size without Socket : 70*75*35 mm
(in and out ) Interface: SO239 (SL16)
Net Weight : 220g
Package
1x HF S.W.R Meter
1x English Instructions
1x USB charger Cable
1x USB power Supply
Push [Blue button] for MENU
1 LCD DIM (Back Light Time) 0-9 1 "0" is OFF, 1 min to 9 mins
2 Auto Power Off Time 0-9 3 "0" is ON , 1 min to 9 mins
3 Adjust mesure power offset -99 to +99 0 "1" is up to 1%,"-1" is down to 1%
* Supplier, the product will add functionality without having to give notice
SET & SAVE:
1. Press MENU [Blue button]
2. Press F1 [Red button)(Select 1-3 Function)
3. Press [Blue button] ( - ) [Yellow button] (+)
4. Press the [Red button ]for 2 seconds
5. Press the [Red button ] 2 second and relest show the save and exit page
6. [Blue button] for save , [Yellow button] not save and exit
Power ON/OFF:
Press [Red button] 2 second to power on or power off
How to Connect your Radio :
TX : Connect to RADIO RF Output
ANT : Connect to ANTENNA or 50 OHM Dummy Load
( Proper adaptor/cable is required if .your device has different type of connectors.)
How to charge your meter :
Connect external USB DC+5V source (e.g. USB charger) to micro USB input
When display is showing 'E', it means the unit is powered by ext. usb in.
When display is showing 'B', it means the unit is powered by internal battery.
How to use a SWR meter to test your antenna : (SWR) : (pic 1)
Measurement V.S.W.R. :
1)Radio RF output connect to meter "TX" socket .
2)Antenna connect to meter "ANT" socket .
3)Push to talke from Radio, METER display is SWR measure data.
How to use a meter to measure the RF output Watt of your transceiver:
Measurement Power Watt :
1)Radio RF output connect to meter "TX" socket .
2)50 Ohm Dummy Load connect to meter "ANT" socket .
3)Push to talke from Radio, METER display is Power measure data .
How to rotate the display:
Press Yellow button and hold to rotate display in 180 degree
DIGITAL HF 1.5-70MHz
POWER & S.W.R. METER
PIC.1
Correctly use the radio to measure S.W.R.
Trouble shooting
1. No Operation?
-PLease charge with USB cable +5V , or come with PSU .
-Push and hold on the "RED" button .
-Replacement battery when battery dead.
-There are still problems with steps 1. and 2.and 3., please contact service center.
2.Watt /S.W.R. read data is not hold on ?
-Some Radio problem when end of TX
.Radio output TX is not stabilizing.
3.Read the watt data is not accurate ?
-Don't not use the antenna get the watt data.
-Please use the correct power dummy load to measure (must be 50 OHM)
-The data read error when not read the frequency from radio
-The TX input is weak , Input Watt below 0.5Watt
4.Read the S.W.R. data is not accurate?
-Do not affect the test in the following cases, there are objects nearby
5.Display have problem ?
e.g.BLack or Garbled or no Display
-Restart , From METER remove the inside battery.
-There are still problems with steps 1. and 2., please contact Retail shop service center.
6. How to RESET the mirco chip
-Off mode ,Hold the Red button and the display show "restore to default "
-There are still problems with steps 1. and 2., please remove the battery.
**All Specifications are subject to change without notice
SWR 1.0 - 1.5: The ideal range!
SWR 1.5 - 1.9: There's room for improvement, but SWR in this range should still provide
adequate performance.
SWR 2.0 - 2.9: While not good, this likely won't damage your radio with casual use.
SWR 3.0+: Performance will be severely affected, and you're likely to damage your radio with
extended transmission use.
IMPORTANT NOTE: Radio damage will only occur when you're TRANSMITTING from an
antenna with high SWR readings. Leaving the radio on to receive signals poses no risk to your
SWR Formulas and Calculations
VSWR can be calculated from various parameters. By definition VSWR is given as
ratio of maximum voltage on the line to the minimum voltage.
The same can be expressed in terms of forward and reflected wave voltages.

Other Surecom Measuring Instrument manuals

Surecom SW-102-UV User manual

Surecom

Surecom SW-102-UV User manual

Surecom SS-10 User manual

Surecom

Surecom SS-10 User manual

Surecom SF-103 User manual

Surecom

Surecom SF-103 User manual

Surecom SF-103 User manual

Surecom

Surecom SF-103 User manual

Surecom SW-102 User manual

Surecom

Surecom SW-102 User manual

Surecom SW33PLUS User manual

Surecom

Surecom SW33PLUS User manual

Surecom SF-103 User manual

Surecom

Surecom SF-103 User manual

Surecom SW-102 User manual

Surecom

Surecom SW-102 User manual

Surecom SF-103 User manual

Surecom

Surecom SF-103 User manual

Surecom SF-103 User manual

Surecom

Surecom SF-103 User manual

Surecom SW-102 User manual

Surecom

Surecom SW-102 User manual

Surecom SS11 User manual

Surecom

Surecom SS11 User manual

Surecom SW-102 User manual

Surecom

Surecom SW-102 User manual

Popular Measuring Instrument manuals by other brands

KLEIBER KS 740-LO Operation manual

KLEIBER

KLEIBER KS 740-LO Operation manual

ABB Relion 670 series Product guide

ABB

ABB Relion 670 series Product guide

PCB Piezotronics 356A43 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 356A43 Installation and operating manual

BorMann BDM6100 user manual

BorMann

BorMann BDM6100 user manual

Brandson 303281/20180509SZ233 user manual

Brandson

Brandson 303281/20180509SZ233 user manual

Greenlee 920XC-13A instruction manual

Greenlee

Greenlee 920XC-13A instruction manual

PROF PROFS7-60M instruction manual

PROF

PROF PROFS7-60M instruction manual

Linertec LTS-202N instruction manual

Linertec

Linertec LTS-202N instruction manual

LIBRA S22 Operation manual

LIBRA

LIBRA S22 Operation manual

Oval PG30 instructions

Oval

Oval PG30 instructions

DATEREMOTE CDS-9020 manual

DATEREMOTE

DATEREMOTE CDS-9020 manual

Minolta FLASH METER III - PART 2 manual

Minolta

Minolta FLASH METER III - PART 2 manual

Kahn Optidew Series user manual

Kahn

Kahn Optidew Series user manual

Storch HPM 3000 manual

Storch

Storch HPM 3000 manual

Elamed EASYTON manual

Elamed

Elamed EASYTON manual

LG RC278 owner's manual

LG

LG RC278 owner's manual

Industrial Scientific Ventis MX4 Operation manual

Industrial Scientific

Industrial Scientific Ventis MX4 Operation manual

Xylem Sensus PolluTherm F Installation and operating instructions

Xylem

Xylem Sensus PolluTherm F Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.