Sven OVP-15P User manual

USER’S MANUAL
www.sven.fi
Voltage Relay
OVP-15P

2
ENG
Voltage Relay
3
3
4
4
4
6
6
7
Congratulations on your purchase of the SVEN voltage relay!
COPYRIGHT
© 2017. SVEN PTE. LTD. Version 1.0 (V 1.0).
This Manual and information contained in it are copyrighted. All rights
reserved.
TRADEMARKS
All trademarks are the property of their legal holders.
NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted efforts to make this Manual more exact, some discre-
pancies may occur. The information in this Manual is given on “as is” terms.
The author and the publisher do not bear any liability to a person or an or-
ganization for loss or damage which has arisen from the information con-
tained in this Manual.
CONTENTS
1. SAFETY AND CAUTION MEASURES ...............................
2. PACKAGE CONTENTS ..................................................
3. APPLICATION ...........................................................
4. FEATURES ...............................................................
5. TECHNICAL DESCRIPTION ...........................................
6. CONNECTION ............................................................
7. OPERATION.............................................................
8.
TECHNICAL SPECIFICATIONS
.......................................
Technical support is on www.sven.fi.

3
ENG
User’s Manual
When the current consumption exceeds 15A, a protective fuse can
be triggered inside the product. Replacement of the protective
fuse is possible in conditions of SC.
The device is not designed for power-cut while short-circuited.
Attention
1. PRECAUTIONS
• Before using the device, please carefully read the following User’s
Manual and save it for the whole operation period.
• Before connecting the device to the power supply network, keep it within
two hours in operating conditions.
• Do not use abrasive materials or organic compounds (alcohol, petrol,
solvents etc.) to clean the device.
• It is prohibited to open and repair the device on your own.
• It is prohibited to open and repair any protected equipment, if it is con-
nected to the device socket.
• It is prohibited to use the device with mechanical damages of its case.
• It is prohibited to use the device in high humidity conditions.
• Avoid ingress of water into the device.
• Does not require special conditions for realization.
• Dispose of in accordance with regulations for the disposal of household and
computer equipment.
Shipping and transportation equipment is permitted only in the original
container.
• Does not require special conditions for realization.
• Dispose of in accordance with regulations for the disposal of household
and computer equipment.
2. PACKAGE CONTENTS
• Voltage relay – 1 pc
• User’s Manual – 1 pc
• Warranty card – 1 pc
OVP-15P

3. APPLICATION
OVP-15P voltage relay is designed to protect household appliances
(conditioners, washing machines, televisions, etc.) connected to it against
inadmissible supply voltage deflections and impulse noises in the power
supply network.
4. FEATURES
• Protection of connected devices against high/low overvoltage in the
power supply network
• Protecting from high-frequency and impulsive noises
• Delay on to protect against repeated failures
• Fixed protection parameters for operation simplicity
• The possibility of manual power-on of the load, before the expiration of
the pause
• Voltage relay status indication
• Protective shutters in the output socket
• Protective grounding contacts, fusible safety device 15А
5. TECHNICAL DESCRIPTION
OVP-15P voltage relay presents a device with an electronic circuit with mic-
roprocessor control assembled in the case with a wall plug and socket.
OVP-15P voltage relay has fixed settings and does not need programming.
OVP-15P voltage relay provides the power supply disconnection of applian-
ces connected to it, if the power supply voltage exceeds specified values,
and automatically recovers the power supply within the specified time after
voltage normalization, in such a manner, it protects the appliances con-
nected to the power supply network against voltage swings dangerous for
them. At that indicators of OVP-15P display the voltage relay status.
4
ENG
Voltage Relay

Design description
a Indicator "low" entrance voltage range
b Indicator "norm" entrance voltage range
c Indicator is "high" entrance voltage range
d ON: button of a force connecting of loading
e Wall plug to connect the voltage relay to 230 V / 50 Hz power supply
network socket
f Protective shutters
g Grounding contacts
f
g
b
c
d
a
e
5
User’s Manual
ENG
OVP-15P
Fig. 1

6. CONNECTION
OVP-15P voltage relay is connected to a standard socket of 230 V / 50 Hz
power supply network. The socket must be rated at the current 16 А.
Protected devices are connected to the output socket of OVP-15P.
The voltage relay is designed for operation indoor only. The device
operation is inadmissible in places with high humidity and where ingress of
liquid on its case is possible. Ambient temperature during the voltage relay
operation must be in the range +10 to +35 °С.
7. OPERATION
The voltage relay has the following operation modes:
• normal operation;
• protection mode;
• turn-on delay mode.
The voltage relay is in normal operation, when the active voltage of the power
supply network is within 199–252 V limit and the turn-on delay time is over.
In this mode the protected equipment connected to the relay is
de-energized, the indicator b lights continuously.
If the voltage exceeds the set thresholds, the relay enters the protection
mode. In this mode the equipment connected to the relay is de-energized
and one of protection indicators starts to light: c when high voltage
protection is actuated or a when low voltage protection is actuated. The
voltage relay will be in this mode as long as the supply voltage attains a value
within 204–244 V ± 2% range.
The relay enters the turn-on delay mode after its connection to the power
supply network or when it leaves the protection mode. In this mode the
equipment connected to the relay remains de-energized till the end of delay
time, and the indicator b blinks during this time. The turn-on delay value
for OVP-15P voltage relay is180 sec.
Force transition from the turn-on delay mode to the operation mode can be
done by pressing the button d.
ENG
6
Voltage Relay

Parameters
Measured voltage range, V / Hz
Maximum load current, A
Maximum permissible load, kW
Protection actuation time
The maximum suppressed energy of
high-voltage pulses, J
The maximum absorbed impulse noise
current, A
Operation threshold to decrease power
supply voltage, V
Operation threshold to increase power
supply voltage, V
Output socket
Dimensions, mm
Weight, kg
Coulor
Value
~100-280/50
15.0
max. 3,3
≤ 0,3 sec
≤125
4500
199 ± 2%
252 ± 2%
1× СЕЕ 7/4
72.2× 87.7 × 78
0.126
white
8.
TECHNICAL SPECIFICATIONS
7
User’s Manual
Notes:
• Technical specifications given in this table are supplemental infor-
mation and cannot give occasion to claims.
• Technical specifications and package contents are subject to chan-
ge without notice due to the improvement of SVEN production.
ENG
OVP-15P

Model:
OVP-15P
Импортер в России: ООО «РЕГАРД», 109052,
РФ, г. Москва, ул. Нижегородская, д. 86, корп. Б.
Уполномоченная организация в России:
ООО «РТ-Ф», 105082, г. Москва, ул. Фридриха
Энгельса, д. 75, стр. 5.
Условия гарантийного обслуживания смотрите
в гарантийном талоне или на сайте www.sven.fi.
Гарантийный срок: 12 мес. Срок службы: 2 года.
Производитель: «СВЕН ПТЕ. Лимитед»,
176 Джу Чиат Роуд, № 02-02, Сингапур, 427447.
Произведено под контролем «Свен Скандинавия
Лимитед», 48310, Финляндия, Котка,
Котолахдентие, 15. Сделано в Китае.
Manufacturer: SVEN PTE. LTD, 176 Joo Chiat Road,
№ 02-02, Singapore, 427447. Produced under the
control of Oy Sven Scandinavia Ltd. 15, Kotolah-
dentie, Kotka, Finland, 48310. Made in China.
® Registered Trademark of Oy SVEN
Scandinavia Ltd. Finland.
Voltage Relay
OVP-15P
Table of contents
Other Sven Other manuals
Popular Other manuals by other brands

YUNEEC
YUNEEC E- GO quick start guide

IrisVision
IrisVision Live! user guide

Elliott
Elliott Roto-Jet I 0620AR Operating and maintenance instructions

Torklift
Torklift A7200 Important owner-operator installation instructions

Thomas Industries
Thomas Industries Rietschle Thomas SK2660 manual

Kogan
Kogan KABTELM327A quick start guide