manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Swegon
  6. •
  7. Industrial Equipment
  8. •
  9. Swegon COLIBRI Free a Guide

Swegon COLIBRI Free a Guide

kpq⋅=
k
pq
=
( )
2
COLIBRI Free x
Tomelilla
Sweden
XXX
k = XX
k
p
q
T
I
L
L
U
F
T
/
S
U
P
P
L
Y
A
I
R
T
I
L
L
U
F
T
/
S
U
P
P
L
Y
A
I
R
F
R
Å
N
L
U
F
T
/
E
X
T
R
A
C
T
A
I
R
Installation
The air diffuser is normally suspended from the ceiling. An M8
pop nut, i.e. a threaded grommet that facilitates installation, is
in the centre of the top of the air diffuser. On the size 315 and
400 air diffusers, there are two M8 pop nuts for more stable
mounting, see figure 2 and 3.
Commissioning
Commissioning should be carried out with the diffuser face
mounted. Pull the measuring tubes and the damper adjustment
cords out of the air diffuser through one disc in the diffuser
face. Then connect the manometer to the correct measuring
tube(s): two blue tubes for supply air and one transparent tube
for extract air. The rated coefficient of performance of the air
register can be used in a calculation to determine the required
commissioning pressure. Conclude commissioning by adjusting
the damper to the correct blade position, tie a commissioning
knot in the damper cords to indicate the damper position. See
Figure 2. The K-factor is specified on the product’s identification
label and last in these instructions.
Maintenance
• Clean the air diffuser if needed with lukewarm water and
dishwashing detergent added.
• The duct system can be accessed and lightly pulling the
spring-loaded diffuser front downwards and then tilting,
see figure 1.
• Dismantle the perforated air distribution plate located on
the inlet as shown in figure 4.
• Loosen the damper in the inlet from its bayonet fastening
by rotating to the side.
Length of straight duct
Type of obstruction upstream of Length of straight duct
upstream of the COLIBRI
Free
COLIBRI Free m2= 5% m2= 10%
One 90° bend 3 ·Ød 2 ·Ød
Two 90°bends in the same plane 4 ·Ød 2 ·Ød
Two 90° bends in alignment at
right angles to one another.
4 ·Ød 2 ·Ød
One 45° damper 6 ·Ød 3 ·Ød
One T-piece 4 ·Ød 3 ·Ød
m
2
= accuracy of the method according to NVG’s report T32:1982
Figur 1. Spring-loaded diffuser front. Figure 4. Dismantling of the perforated air distribution plate.
Figure 3a. Alternative installation.
k-factor
q= flow reading l/s
p= current pressure reading (Pa)
k= commissioning factor
Figure 2. Installation. Commissioning. Maintenance.
Applies only for
size 315 & 400
Figure 3b. Extra M8 pop nut, size 315 and 400.
COLIBRI Free a
Installation – Commissioning – Maintenance 20181004
Figure 5. COLIBRI Free.
K-factor (COP)
COLIBRI F supply air
Size k-factor Tube colour
100 4,5 Blue + Blue
125 7,4 Blue + Blue
160 13,6 Blue + Blue
200 22,4 Blue + Blue
250 34,5 Blue + Blue
315 57,6 Blue + Blue
400 95,8 Blue + Blue
Number of measuring tubes: 2
COLIBRI F extract air
Size k-factor Tube colour
100 5,1 Transparent
125 8,0 Transparent
160 12,9 Transparent
200 20,0 Transparent
250 25,4 Transparent
315 36,6 Transparent
400 42,5 Transparent
Number of measuring tubes: 1
Disc settings – examplesl
Figure 6. Disc settings.
NOTE: Air direction in the figure.
1. Clockwise swirling air discharge (standard)
2. 1-way
3. 2-way
4. 3-way
5. 4-way
6. V1 Vertical Concentrated
7. V2 Vertical Diffused
!
Dimensions and weights
Size A B C D E Number of
discs
Weight,
kg
100 304 192 118 99 96 36 2.8
125 380 217 210 124 108 55 4.1
160 456 252 220 159 126 84 5,7
200 568 288 230 199 144 130 8.3
250 568 338 275 249 169 136 9.2
315 700 388 330 314 194 186 13.6
400 700 488 350 399 244 200 16.1
COLIBRI Free
2Swegon reserves the right to alter specications. 20181004

Other Swegon Industrial Equipment manuals

Swegon BELIMO ZTH-GEN Guide

Swegon

Swegon BELIMO ZTH-GEN Guide

Swegon GOLD CX Instruction Manual

Swegon

Swegon GOLD CX Instruction Manual

Swegon EXP Free a Guide

Swegon

Swegon EXP Free a Guide

Swegon CASA W03CMB User manual

Swegon

Swegon CASA W03CMB User manual

Swegon BlueBox Titan Sky Hi R0 Service manual

Swegon

Swegon BlueBox Titan Sky Hi R0 Service manual

Swegon IBISa Guide

Swegon

Swegon IBISa Guide

Swegon AQUA Link User manual

Swegon

Swegon AQUA Link User manual

Swegon DVCe User manual

Swegon

Swegon DVCe User manual

Popular Industrial Equipment manuals by other brands

ABB +Q957 user manual

ABB

ABB +Q957 user manual

G.B.C BASIC EDGE 50 instruction manual

G.B.C

G.B.C BASIC EDGE 50 instruction manual

Tronair Batpak 11-6602-1000 Operation & service manual

Tronair

Tronair Batpak 11-6602-1000 Operation & service manual

Pilz PNOZ mi2p Operation manual

Pilz

Pilz PNOZ mi2p Operation manual

Clemco Zero BNP 6012 manual

Clemco

Clemco Zero BNP 6012 manual

Erskine Attachments V-Plow Operator's manual

Erskine Attachments

Erskine Attachments V-Plow Operator's manual

ABB HT610965 Operation manual

ABB

ABB HT610965 Operation manual

Morra MH 540 user manual

Morra

Morra MH 540 user manual

Eaton S090ST manual

Eaton

Eaton S090ST manual

GRIGGIO G 240 P4 instructions

GRIGGIO

GRIGGIO G 240 P4 instructions

Nexen AIR CHAMP HT45 user manual

Nexen

Nexen AIR CHAMP HT45 user manual

WTE V5 installation manual

WTE

WTE V5 installation manual

ABB HT845232 Operation manual

ABB

ABB HT845232 Operation manual

SMC Networks CJP Series Operation manual

SMC Networks

SMC Networks CJP Series Operation manual

JohnDow Industries JDI-AFT58 Operator's manual

JohnDow Industries

JohnDow Industries JDI-AFT58 Operator's manual

IMB MB9016A instruction manual

IMB

IMB MB9016A instruction manual

Clarke CUMB1 Assembly & operating instructions

Clarke

Clarke CUMB1 Assembly & operating instructions

amiad Arkal Spin Klin 2 user guide

amiad

amiad Arkal Spin Klin 2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.