Synel PrintX-FPR User manual

-
1
Manual 7/12/09. Catalog no. 650460 Document no. FPR-PRX-222-01
PRX-40/B
Terminal
&
PrintX FPR
(FingerPrint
Reader)
STAND-ALONE TERMINALS
Product Manual

-
2
All rights reserved. Reproduction or use, without express permission of editorial or pictorial content,
in any manner is prohibited. No patent liability is assumed with respect to the use of the information
contained herein. While every precaution has been taken in the preparation of this manual, Synel
Industries Ltd. assumes no responsibility for errors or omissions. Neither is any liability assumed for
damages resulting from the use of the information contained herein.
DCM and SY are trademarks of Synel Industries Ltd.
All trade names referenced herein are either trademarks or registered trademarks of their respective
companies

3
Contents
Introduction .................................................... 5
Apparatus........................................................ 7
Technical Specifications................................ 8
3.1Electrical characteristics 8
3.2Package 9
Installation..................................................... 10
Finding the best location for the units ....... 10
Mounting PRX-40/B and PrintX FPR........... 12
Connecting the Cables ................................ 15
7.1PRX-40/B Connection Wires 17
Jumpers ........................................................ 20
8.1PRX-40/B 20
Setting-up the Standalone unit ................... 21
9.1To use Proximity Card and Fingerprint mode: 21
9.2Setting Proximity Card parameters: 21
9.3Entering Proximity Cards and Fingerprints to the unit:
22
9.4To use Pin number and Fingerprint mode: 22
9.5Entering Pin numbers and Fingerprints to the unit:
22
9.6Specify if using Identify or Verify mode: 23
Operation ...................................................... 24
10.1PrintX-FPR Operation 24

4
Communication ............................................ 26
Communication cables characteristics ..... 26
Fingerprint Best use Guidelines................. 27
Troubleshooting ........................................... 28
Appendices:
Detailed instructions for Standalone Set-up 30
1.1Access cards configuration (Set-up codes) 30
1.2Access cards configuration 34
Additional Stand alone unit combination options
39

Back to Table of Contents
5
1Introduction
The PRX-40/B reader and PrintX-FPR fingerprint reader Standalone, as a stand alone biometric
solution for access control.
The proximity and biometric units are adjacently installed at sensitive
locations for granting access to secure zones.
Setup, management of authorized, and definitions are all done directly on the
units. Defining parameters in PRX-40/B and PRintX-FPR is simple, and the
templates and an authorized list are created and edited using the keyboard.
P
RX-40/B & PrintX-FPR were developed as compact, easy-to-use terminals,
granting access to secure areas. They work with various unit settings,
according to a predefined security level. These devices are made of strong
ABS plastic.
Defining parameters is simple while maximum security is enabled by using
the set-up 8 digit code (the default number is 12345678) maximizing security.
In stand alone mode these units grant secure access for approximately 285
card holders, stored in an authorized list within the terminal. This list is created and edited on the
unit’s compact keyboard, eliminating the need of connecting to a computer.
These terminals can manage unauthorized (black list) or authorized (white list) employee lists for
access control purposes.
The PRX-40/B and PRintX-FPR Standalone can be used in the following modes:
Identification - In this mode user is only identified by a fingerprint and is not verified by an
additional means of identification.
The finger is placed on the sensor and is either accepted or rejected immediately.
In this mode, the keyboard unit can be installed in a different location such as on the other side of the
door. In this case The user is identified my finger on one side and by card or pin number on the other
side of the door.
Identification mode supports up to 9,000 authorized people.

Back to Table of Contents
6
Verification - In this mode user is identified by wither a card or by pin number on the key board, and
then verifies their identity with by fingerprint.
Verification can be done in the following ways:
• Swipe card > Fingerprint
• Pin number > Fingerprint
Access is available for up to 9,000 card holders.

Back to Table of Contents
7
2 Apparatus
In stand-alone mode (when the device functions as a controller) this unit has additional circuitry for
storing card-holder data.
PRX-40
/
BPr
i
ntX FPR
LED Operation
Status Indicator
LED Operation
Status Indicator
Fingerprint sensor
Keyboard
Bell button

Back to Table of Contents
8
3 Technical Specifications
PRX 40/B
• Dimensions: 15.5 x 7 x 6.1 cm
• Weight: 350 gr
• Operating temperature: -10 to +50°C
PrintX FPR
• Dimensions: 15.5 x 7 x 6.1 cm
• Weight: 350 gr
• Operating temperature: -10 to +50°C
3.1 Electrical characteristics
• Output relay rating: 24 V @ 3 A
• Tamper sensor output TTL level max @ 16 mA

Back to Table of Contents
9
3.2 Package
The terminal package contains:
Check the box and contents for signs of damage that may have occurred during shipment. Don’t throw away
the box or any of the packing materials
1x PRintX FPR unit
1x PRX 40/B unit
A mounting set that includes:
2 screws for mounting the mounting panel
2 screw for securing the unit to mounting panel
Wall anchors:4 Brick + 4 Plaster
1x RJ-11 Connection box with cables for 12V
power connection (for PRX 40/B)
1x RJ-45 Connection box with 5V power input
(PrintX FPR)
PRintX/P power supply adaptor:
5 Volt/1 A stabilized wide range input 100-240 AC input
User guide on CD 2x Mounting pannels

Back to Table of Contents
10
4 Installation
5 Finding the best location for the units
Follow the guidelines below to find the best place to mount the terminal:
• Place the units by an easily accessible power outlet.
• Do not place communication cables near a source of electromagnetic radiation or radio interference
such as power lines, large machinery, etc.
• Do not place the units where exposed to extreme hat or cold, water, steam, violent vibrations or
strong electromagnetic radiation including high voltage power lines and electrical equipment.
• The installation location selected should be as far as possible from sources of electrical reference
such as power equipment, computers, motors, pumps, etc.
• Maintain at least a one meter distance from computer displays.
• Keep the cable by at least 30 cm away from any other cable.
• Use a power adaptor dedicated to the proximity unit. Make sure the adapter carries a safety
recognition marking such as UL, CSA or CE.
• If you are installing more than one Synel proximity reader, make sure the readers are installed at a
distance of at least 50 cm from one another (5 times the unit reading limit).
• Use a linear power supplier and not a switching power supplier which generates an electro-
magnetic field that shortens the reading range.
It is advisable to connect an independent power supplier to the reader.
• Make sure there are no metallic materials surrounding the unit.
• When mounting on a drywall (gypsum wall), make sure that there are no rear metallic
reinforcements to the wall.
• Make sure that it is safe to drill into the wall at the desired location.

Back to Table of Contents
11
• The units should be mounted at employee eye-height. Consider accessibility of handicap users, if
necessary. The standard recommended height is 140cm (4’7”).
• Place the reader so that the user will be fully facing it when swiping the badge since this is the best
swiping position.
Caution:The terminal contains computer components. Thus it should not be mounted where it
will be exposed to extreme heat or cold, water, steam, violent vibrations, high electromagnetic
radiation including high voltage power lines and electrical equipment.

Back to Table of Contents
12
6 Mounting PRX-40/B and PrintX FPR
1. Select a location for the terminal using the following guidelines for find-
ing the best location, above.
2. Hold the mounting template to the wall and mark the places to drill holes
for the screws and cables.
3. Drill the holes for the connection cable and screws (with 6mm. drill bit).
4. Inset the screw anchors for either plaster or concrete, as needed.
5. Thread the cable through the wall and connect to external components
as needed.
Mount the panel to the wall and adjust it so that it is straight and the
cable is in place.

Back to Table of Contents
13
6. Slide the unit downward onto to the mounting panel.
The hinges at the side of the panel (1) should slide into the track of the mounting panel (2).
1
2

Back to Table of Contents
14
7. Once the unit is in place you can screw the security screw, connecting between the panel and the
unit, at the top of the unit and panel.

Back to Table of Contents
15
7 Connecting the Cables
PRX-40B Communication Box

Back to Table of Contents
16
Print-X-FPR Communication Box

Back to Table of Contents
17
Wire connections of Fingerprint connection box
Wire connections of Proximity Card connection box
7.1 PRX-40/B Connection Wires
The wires are connected to external components as listed in the table below.
From Name Color RJ11 Box1
P2/5 +5Vdc Purple 7
P3/5 +5Vdc Brown 7
P2/1 GND Blue/White 3
P2/9 GND Brown/White 3
P2/3 Host Rx Orange 2
P2/2 Host Tx Green 4
From Name Color RJ45 Box2
P1/1 Clock /D1 Green 6
P1/2 Clock /D0 Blue 7
P1/4 +5Vdc Red 3
P1/5 GND Black 4
LED1/2 (+) C.Anode Black 3
LED1/2 (G) Green LED Light Green 5
LED1/2 (R) Red LED Pink 2
Wire No. Wire Function Present Color Code
1Vin Power (VCC) Red
2Gnd Black
3- TxRx RS-485 Grey
4+ TxRx RS-485 Purple
5TxD RS -232 White
6RxD RS -232 Green
7Tamper Control Brown
8Normal Neutral (C) Blue
9Normally Closed (N.C) Yel l ow
10 Normally Open (N.O.) Orange

Back to Table of Contents
18
Wire connection diagram
11 Bell (1) Pink
12 Bell (2) Light green
13 (optional) as needed Light blue
14 (optional) as needed Brown + White or Brown + Black

Back to Table of Contents
19
PRX-40/B Wire connection diagram

Back to Table of Contents
20
8Jumpers
8.1 PRX-40/B
Jumper Function Default
JP2 (SMD) JP2 closed and JP3 open = 13 digits decoding
JP2 open and JP3 closed = 14 digits decoding
13 digits
JP3 (SMD)
JP4 (SMD) Cross point decoding (currently NA)
JP7 (SMD) Connect RS-485 termination resistor Open
JP10 (TH) W.D. Reset for the master CPU- [1-2] Closed
Programming of the master CPU - [2-3] Closed
[1-2] closed
JP11(TH) PSEN (Programming) - must be closed when programming
the master CPU.
Open
JP12 (SMD) Tamper switch enabled [1-2] closed
Tamper switch disabled [2-3] closed
[2-3] closed
JP20 (T.H) Closed- Stand alone
Open- Online with Master
Closed
JP21 (T.H) Contacts switching protection in DC- closed
Contacts switching protection in AC- open
Closed
JP22 (SMD) Connecting clock to slave CPU [2-3] closed
JP23 (T.H) Select sensor option:
[1-2] and [3-4] Closed - dry contact
[2-3] Closed - AC/DC
[1-2] and [3-
4] closed
JP24 (T.H) Reset for the slave/reader CPU- [2-3] closed
Programming of the slave/reader CPU [1-2] Closed
[2-3] closed
This manual suits for next models
1
Table of contents
Other Synel IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

H3C
H3C WX5002ACCESSCONTROLLER installation manual

ACT
ACT ACTPRO 3000 ACCESS CONTROL UNITS datasheet

Kaba
Kaba ILCO RAC 660G XT installation guide

SPORTS AFIELD
SPORTS AFIELD INSTINCT BIOMETRIC Series instruction manual

IDTECK
IDTECK Star 100R Quick installation guide

Grosvenor
Grosvenor Sateon Advance 2 Door Blade installation guide