ektor EV-AWAC-KIT User manual

1. WELCOME
CODE:6100
CODE:6120
CONTENTS
Installation Instructions
1. Welcome
2. Safety Warnings
3. Advanced Wide Access Controller
4. Why Use an AWAC
5. Installation
6. AWAC Contents
7. AWAC Description
8. Functions and Status
9. AWAC Commissioning
10. Accessories List
11. Product Specifications
12. Warranty Information
13. Compliance Standards
14. Technical Support and Troubleshooting
Thank you for choosing this quality
Ektor product. This manual is
intended to help you install this
product in a way that ensures the
safety of yourself and others. Whilst
this Ektor product is designed to be
installed easily, we highly recommend
you take the time to read this manual
thoroughly before commencing
installation. When installed correctly
and serviced regularly, this product
will provide hassle free operation for
many years.
6100 EV-AWAC-KIT
6120 EV-WAC-INT2C
1

ADVANCED WIRED ACCESS CONTROLLER INSTALLATION INSTRuCTION
Straight out of the box one of the many features of the AWAC is its ability to commission and fault find on
the network with an iPhone or other smart phone, as well as logging and reporting tests and maintenance. Its
GUI web interface makes commissioning and reporting easy(PC with TCP/IP access to the AWAC required).
The AWAC system can also connect to multiple AWAC devices via Cat5 to create larger networks and
email reports and logs (with additional internet connection, SMTP server, or additional 3G wireless card). In
addition the AWAC features optional Server test software for on-site testing and optional Web 2.0 hosting
for remote logging and testing.
2. SAFETY WARNING
3. ADVANCED WIRED ACCESS CONTROLLER
4. WHY USE THE AWAC
1. THIS PRODUCT MUST ONLY BE INSTALLED BY A LICENSED ELECTRICIAN.
2. BEFORE COMMENCING INSTALLATION TURN OFF AND ISOLATE THE ELECTRICAL SUPPLY.
3. DO NOT TOUCH THE TERMINAL BLOCK OR CIRCUITRY WHEN THE AWAC IS ENERGIZED.
4. THERE ARE NO USER SERVICEABLE PARTS. DO NOT ATTEMPT TO SERVICE ANY PARTS OF THE AWAC AS THIS
WILL VOID THE WARRANTY.
5. AS THE INSTALLER, IT IS YOUR RESPONSIBILITY TO ENSURE YOU COMPLY TO ALL RELEVANT\BUILDING AND
SAFETY CODES FOR EXAMPLE THE BCA, AS3000. REFER TO APPLICATION STANDARDS FOR THE RELEVANT RULES.
6. WHEN INSTALLATION IS COMPLETE, PLEASE LEAVE THIS MANUAL WITH THE BUILDING’S OWNER/S FOR
FUTURE REFERENCE.
The Advanced Wide Access Controller (AWAC) from Ektor is a complete solution for emergency monitoring
and testing. Utilizing the power of an ARM processor, emergency testing and monitoring enters a new era.
The standalone AWAC system is able to perform all your testing and monitoring requirements without
needing a server or more expensive testing systems. This system also has the capability of supporting an
almost unlimited number of wired emergency devices.
2
FEATURE
SMSing
Email
Smart device/iPhone compatible
2.0 Webserver
Server test software for on-site testing
Web 2.0 hosting for logging/testing
WITH ADDITIONAL MODELS
VIA INTERNET CONNECTION
OPTIONAL
OPTIONAL

Emergency Timer
and Circuit Sense
(2002 EV-EM-Timer)
AWAC
(6100 EV-Advanced )
WAC
(6120 EV-DALI-INT2C)
NEN
L LLL LL LL
L
NN
L
STANDARD EMERGENCY WIRING MONITORING SYSTEM WIRING
Line 2
Emergency Lighting
MAX 64 units
MAX 300m @1.5mm² cable
MAX 500m @2.5mm² cable
Ethernet Cable
RJ45 Cable Link
rotect ve ev c
rot ct v v c
P
rotect
i
ve
D
ev
i
c
e
P
rot
e
ct
i
v
e
De
v
i
c
e
Protective Device
L
Protective Device
To Lighting
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Line 1
5. INSTALLATION
The AWAC can be installed in two ways - either as a small system or as a large system.
5.1 AWAC wiring diagram Below is the suggested wiring diagram for the AWAC to a basic standalone
emergency system. It is suggested that the AWAC is installed at the distribution board. Each WAC can
support 2 lines of 64 emergency devices.
3
Figure 1: Monitored System Wiring
-AWAC-KIT
EV-WAC-INT2C

ADVANCED WIRED ACCESS CONTROLLER INSTALLATION INSTRuCTION
4
5.2 Interconnecting AWACs Multiple AWACS can be connected together to create a larger system. Using
cat5 cable each AWAC can be connected to an Ethernet/IP router. Multiple Ethernet routers can be
connected together to form a larger system. Other devices such as PCs, smart devices, wireless routers and
even an internet modem can be connected to this system. NOTE: The network needs to support 10/100
switching. If wireless routers are connected to the systems they should ideally be placed in a position to give
the maximum coverage throughout the building.
Figure 2: Interconnecting AWACs
Figure 3: Monitored System Wiring Close-up
Network Router
To other Network Router
Network Router
To other Advanced Wired
Access Controllers (AWACs)
To other Advanced Wired
Access Controllers (AWACs)
To Wired Access Controller (WACs)
AWAC
(6100 EV-Advanced-
Wired-Access-Controller)
To Wired Access Controller (WACs)
ETHERNET
SERIES
ETHERNET
ETHERNET
ETHERNET
SERIES
AWAC
(6100 EV-Advanced-
Wired-Access-Controller)
A/LN
A/LN
RJ45 Cable Links
WAC
(6120 EV-DALI-INT2C)
L
N
L
N
Line 2
Line 1
To Emergency Lighting To Emergency Lighting
Ethernet Cable
(6100 EV-Advanced-
Wired-Access-Controller)
ETHERNET
SERIES
OPTIONAL WAC
L
N
Line 2
Line 1
AWAC
(6100 EV-AWAC-KIT)
(6100 EV-AWAC-KIT)
To other Advanced Wide
Access Controllers(AWACs)
(6100 EV-AWAC-KIT)(6120 EV-WAC-INT2C)
(6120 EV-WAC-INT2C)

5
5.2 Building wide installations Below is a typical example of a building layout. Ideally an AWAC should be
placed on each floor and connected to a central router. It is possible to wire a number of floors to a single
AWAC as long as the maximum cables runs are not exceeded. Smaller networks are easier to commission
and control, however each line can support up to 64 emergency devices.
Figure 4: Typical Building Layout

ADVANCED WIRED ACCESS CONTROLLER INSTALLATION INSTRuCTION
6
The AWAC is sold as one kit including:
• 1x Wired Access Controller (WAC)
• 1x Green Interlinking Cable
• 1x Advanced WideAccess Controller (AWAC)
6. AWAC CONTENTS
1
2
3
3

7
7. AWAC DESCRIPTION
Figure 4: AWAC functions Figure 5: WAC functions
AWAC description:
• INFO
• WEB
• SERVICES
• SERVICES 1
• SERVICES 2
• ERROR
WAC description:
• ADDRESS 1
• VERIFY 1
• ADDRESS 2
• VERIFY 2
• INDICATOR1
• INDICATOR 2
8. AWAC FUNCTIONS AND STATUS
The table below shows the status indicators of the buttons and status LEDs.
INDICATOR STATUS DESCRIPTION
WEB
INFO
WEB
SERVICES 1+2
ERROR
ON
SHORT FLASHING
1 SEC CONTINOUS
ON
FLASHING
ON
FLASHING
NOT USED
Working
A button has been pressed and a function begins
A button is being pressed and held
Webserver is on
Webserver is off/restarting
System running
Input error Restart webserver

ADVANCED WIRED ACCESS CONTROLLER INSTALLATION INSTRuCTION
8
9.WAC COMMISSIONING
Below details the method used to commission the WAC, its dual function control system buttons:
DALI LINE 2DALI LINE 1
MOMENTARY
SWITCH
ON/OFF
ADDRESS
ON/OFF
ADDRESS
IDENTIFY
IDENTIFY
ADDRESSED
DEVICES
IDENTIFY
IDENTIFY
ADDRESSED
DEVICES
Power on/off
for line 1
Addressed DALI
line 1 will finish on
its own
Power on/off
for line 2
Addressed
DALI line 2.
will finish on
its own
Check if all are
plugged into
DALI line 1
Check if all devices
are addressed
Check if all are
plugged into
DALI line 2
Check if all
devices are
adressed
PRESS & HOLD
10. ACCESSORIES LIST
Below are the listings of the compatible accessories for use with the AWAC.
PART EVOLT CODE CODE
WIRED ACCESS CONTROLLER (WAC)
INTERLINK CABLE
EMERGENCY TIMER
EMERGENCY TIMER ASSEMBLY
EV-WAC-INT2C
EM-TIMER-INTERLINK
EV-EM-TIMER
EV-EM-TIMER ASM
6120
6122
2002
2003

11. PRODUCT SPECIFICATIONS
ADVANCED WIDE ACCESS CONTROLLER (AWAC)
180 mm
106 mm
63 mm
106 mm
WIRED ACCESS CONTROLLER (WAC)
92 mm
92 mm
63 mm
72 mm
Operating voltage (V)
Operating frequency (Hz)
Operating Current
Operating Temperature
IP Rating
Wiring
AWAC Weight
Mounting Surface
Mains Connection
6mm terminals
197 grams
Field mounted DIN Rail
(35mm)
Screw terminal for 1 -
4mm2cable
230VAC
50Hz
0.08A
0 to 50°C
IP20
Operating voltage (V)
Operating frequency (Hz)
Operating Current
Operating Temperature
IP Rating
Wiring
WAC Weight
Mounting Surface
Mains Connection
6mm terminals
175 grams
Field mounted DIN Rail
(35mm)
Screw terminal for 1 -
4mm2cable
230VAC
50Hz
<0.086A
0 to 50°C
IP20
9

ADVANCED WIRED ACCESS CONTROLLER INSTALLATION INSTRuCTION
12. WARRANTY INFORMATION
Ektor products are distributed in Australia and New Zealand by Evolt Pty Ltd (Evolt).
The Australian Consumer Law as well as other Australian laws guarantee certain conditions, warranties and
undertakings, and give you other legal rights, in relation to the quality and fitness for purpose of Ektor products
sold in Australia.
In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure. What constitutes a major failure is set
out in the Australian Consumer Law.
Nothing in this Warranty purports to modify or exclude the conditions, warranties and undertakings, and other
legal rights, under the Australian Competition and Consumer Act and other Australian laws.
Ektor products are warranted in Australia for a period of 12 months from the date of delivery of the product,
provided that the products are properly stored, installed, used and maintained in accordance with the
instructions contained within their manual.
Products that have been altered in any way or used other than in accordance with their instructions are not
covered by this warranty.
This warranty is not transferrable and is valid only in the hands of the purchaser of the product. The warranty
does not cover Ektor products other than those purchased from Evolt. Proof of purchase must be provided to
Evolt with any warranty claim. Evolt recommends that the purchaser attaches their proof of purchase to their
product manual.
Evolt’s total liability under this warranty is limited to the cost of repair or replacement of the faulty product. Evolt
may satisfy its obligations under this warranty in full by repair or replacement of a faulty product.
This warranty does not apply to consumable items such as lamps or batteries or other items that can be
classified as consumable.
For the avoidance of any doubt, any and all warranties or conditions which are not guaranteed under the
Australian Competition and Consumer Act or the Australian Competition and Consumer Regulations 2010 and
which are not expressly included in this Warranty as additional warranties or conditions are excluded.
This Warranty does not cover loss or damage caused by wear and tear, misuse, incorrect installation or
operation, failure to clean and maintain, incorrect voltage or non-authorised electrical connections, adverse
external conditions (such as power surges and dips, acts of God, exposure to heat, corrosion, insect or vermin
infestation), use of non-authorised or defective parts or globes, or to items that have been repaired other than
by Evolt or a repairer approved by Evolt.
10

11
13. COMPLIANCE STANDARDS
14. TECHNICAL SUPPORT AND TROUBLESHOOTING
For further assistance in using this product, consult your nearest wholesaler or Evolt Pty Limited.
STANDARD TITLE
Emergency escape lighting and exit signals for
buildings. Part 1: System design, installation and
operation.
Particular requirements for miscellaneous electronic
circuits used with luminaires.
(IEC 61347-2-11:2001 MOD)
Particular requirements for miscellaneous electronic
circuits used with luminaires.
Specification for equipment for general lighting
purposes. EMC immunity requirements.
Limits and methods of measurement of radio
disturbance characteristics of electrical lighting and
similar equipment.
Australian/ New
Zealand Standards
AS/NZS 2293.1
AS/NZS 61347-2-11
EN 61347-2-11
EN 61547
EN 55015
European
Committee for
Standardisation

Ph: + 612 9502 1161
Fax: + 612 9502 1154
Email: [email protected]
evolt.com.au
Reference: 2015-110315 604418 V1.4
This manual suits for next models
3
Table of contents