USER’S MANUAL
B100P-BT-EH-SA
Bluetooth® standalone biometric reader with integrated RFID reader
EN
1. SPECIFICATIONS
User capacity:
Relays:
Output:
Entry mode:
RFID reading type:
Reading distance:
Power supply:
Buzzer, backlight control:
Tamper:
RS-485 interface:
Door Open Time:
IP Factor:
Operating Temperature:
Operating Humidity:
Firmware upgrade:
Wiegand output:
Programming:
Door operation:
Holidays:
Event capacity:
100 fingerprints and 100 Cards
1 or 2 depending on the remote relay unit
1 with RTT and RU1 and 2 with RU2 and DINRTT
RS-485, Wiegand
Fingerprint, Card, Fingerprint or Card
EM 4002/4100 and HID (125kHz)
up to 4cm
12 VDC; max. 100mA
Yes, ON/OFF via XPR Smart Admin
Yes
Yes, for connecting I/O boards like
RU1, RTT, RU2, DINRTT
0 to 255 sec. or toggle (ON/OFF mode)
IP65
-20°C to +50°C
5% to 95% RH without condensation
Yes, via Bluetooth® wireless technology
Wiegand 24, 26, 32, 34, 56, 58 bits
via XPR Smart Admin
via XPR Smart Access
24
4000
1
2. MOUNTING
4.
1.
Cable
Ø6.0(3NoS)
30mm
5mm
2.
3 (3 x 30mm)
3.
1 (M3 x 6mm)
MC-MINI
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MC-MINI metal cover available in our accessories in order to protect
the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a
third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot
guarantee the functionality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use
different readers depending on users.
3.0 RESET READER TO DEFAULT
1. Turn the device OFF
2. Put dipswitch 1 to position ON
3. Turn the power ON
4. Wait approx. 15 seconds until continuos beeps.
5. Put dipswitch 1 to OFF
6. Wait for long beep.
The reset procedure will bring the reader to default. The
password will be deleted, all the users and the reader will be
unpaired from the remote relay unit.
Unpairing the reader after reset, prevents unauthorized
reset and keeps the unit in high security state.
Important note:
The Bluetooth reader comes with RU1 remote relay ®
unit.
Make sure to make firmware update with the latest
available firmware.
51mm
92mm
27mm
v.b8
ON
1 2
Reset
Service mode
2
4. WIRING AND PAIRING
The Bluetooth reader must be connected to
remote relay unit, unless is used as wiegand
reader.
The remote relay units compatible with B100P-BT-
EH-SA are RU1, RU2, RTT and DINRTT. Once
connected, the remote relay unit must be paired
with the Bluetooth reader.
Pairing the reader with remote relay unit is done
from the remote relay unit and enables added
security. After being paired, it is not possible to
switch any of the devices, since the reader will
work only with the paired remote relay unit.
Grey
Red
Black
White
Yellow
Pink
Blue
Violet
+12V
GND
D0
D1
RS-485
Power Supply
Wiegand
Tamper
A
B
to remote relay unit
to wiegand controller
IN
RS-485 (max. 50m)
DINRTT
2 Relay Remote Unit
and request-to-exit Button
RTT
1 Relay Remote Unit
and request-to-exit Button
RU2
2 Relay Remote Unit
OR
Secured Area Unsecured Area
+12V
GND
NO
COM A
B
NC
PB
RS-485
Power
Supply
GND_P B
RU1
1 Relay Remote Unit
B100P-BT-EH-SA
Bluetooth standalone biometric reader
with integrated RFID reader
4.1 Wiring and pairing B100P-BT-EH-SA + RU1
+12V
GND
NO
COM A
B
NC
PB
RS-485
Power
Supply
GND_PB
white
yellow
gray
red
black
blue
orange
violet
pink
Black
Red
Pink
Violet
Reader
Exit Button
12 VDC +
-
+
-
max. 50 m
Pairing Reader with RU1 (high security)
- Keep the button pressed
for at least 5 sec. and the
units will be paired.
There are four options to wire and pair the reader. It can be paired to RU2, RU1, DINRTT and RTT.
4.2 Wiring B100P-BT-EH-SA to Wiegand Controller
Grey
Red
Black
White
Yellow
Pink
Blue
Violet
12V
DC(CC)
D0
D1
+
-
Host/ Unité Centrale/ Unita' centrale/
Sistema receptor/ Controller/ Controller
Max 150m
By default, the reader is set to Wiegand 26
bit.
You can set the reader, using the software,
to Wiegand 24, 26, 32, 34, 56, 58 bits.
Other pairing devices:
Device Description Relays
RU2
DINRTT
RTT
Flush mount sensitive push button and remote relay
DIN rail mount remote relay unit
Surface mount sensitive push button and remote relay
2
2
1
3
5.0 SETTING UP READERS WITH XPR SMART ADMIN WINDOWS SOFTWARE
1. Add site first.
2. Click on “ADD” reader.
3. Select type “B100P-BT-EH-SA”.
4. Scan for readers near by by clicking on “Scan”. Found readers will
be listed (pic.2). Click on “Select”.
5. Add a pairing key between the PC and the Bluetooth reader and a
password. (pic. 3)
6. If the pairing is successful, the buttons in the reader section will
be enabled.(pic.4)
pic. 1
pic. 2 pic. 3
pic. 4
You can download 2 softwares for Windows: XPR Smart Access and XPR Smart Admin from our website:
Users Software
Application for users,
allowing them to manage
the doors from a distance.
(max distance: 10m).
Software for the installation
administrator, allowing him/her to
program all readers and update
them, manage users and their
access rights, download events
and edit reports.
Administrator Software
6. ADDING USERS
1. Go to Users and select the user. Edit the name directly. Enable it.
2. Put a PIN Code and Card ID. The Card ID can be read directly from
the reader or from USB desktop reader.
3. Select proper Access level and validity period.
4. Go to “Biometry” tab and enroll fingerprints by swiping min. 6
times each finger.
5. After this, go to the reader and “Upload users to reader”.
The 2 smartphone apps are available in:
Smart
Access
Users App
Application for users, allowing them
to manage the doors from a
distance.
(max distance: 10m).
Smart
Admin
Administrator App
Application for the installation administrator,
allowing him/her to program one reader at a
time and update it, manage users and their
access rights, download events and edit
reports. (max distance: 10m).
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2
directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
Web page
wwww.xprgroup.com

Other xpr IP Access Controllers manuals

xpr DINB100-SA v2 User manual

xpr

xpr DINB100-SA v2 User manual

xpr VPROX2-M User manual

xpr

xpr VPROX2-M User manual

xpr DINMTPX-EH User manual

xpr

xpr DINMTPX-EH User manual

xpr B100PROX-EH-SA v2 User guide

xpr

xpr B100PROX-EH-SA v2 User guide

xpr BIOPROX-EM User manual

xpr

xpr BIOPROX-EM User manual

Popular IP Access Controllers manuals by other brands

Sebury BC2019 instruction manual

Sebury

Sebury BC2019 instruction manual

ZKTeco FaceKiosk-H10A quick start guide

ZKTeco

ZKTeco FaceKiosk-H10A quick start guide

NetComm IAC4000 Specifications

NetComm

NetComm IAC4000 Specifications

ATN Thermal Entry Wizard quick start guide

ATN

ATN Thermal Entry Wizard quick start guide

IDTECK FINGER007 Series troubleshooting guide

IDTECK

IDTECK FINGER007 Series troubleshooting guide

uAttend CB 1500 Quick start guide & user manual

uAttend

uAttend CB 1500 Quick start guide & user manual

PreCise Biometrics Precise 100 A quick reference

PreCise Biometrics

PreCise Biometrics Precise 100 A quick reference

Burg secuENTRY easy PINCODE Assembly and user's manual

Burg

Burg secuENTRY easy PINCODE Assembly and user's manual

Roger MCT82M-IO-CH operating manual

Roger

Roger MCT82M-IO-CH operating manual

FingerTec TA100C user manual

FingerTec

FingerTec TA100C user manual

Samson S1 instructions

Samson

Samson S1 instructions

Amano FPT-80 quick start guide

Amano

Amano FPT-80 quick start guide

DESi PiKS FC 80 user manual

DESi

DESi PiKS FC 80 user manual

H3C WBC580 G2 Installation, quick start

H3C

H3C WBC580 G2 Installation, quick start

Dahua DHI-ASI7213X-T quick start guide

Dahua

Dahua DHI-ASI7213X-T quick start guide

3MillID 3M Inline installation guide

3MillID

3MillID 3M Inline installation guide

Idemia MorphoWave Compact installation guide

Idemia

Idemia MorphoWave Compact installation guide

Austin Hughes InfraSolution X Series user manual

Austin Hughes

Austin Hughes InfraSolution X Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.