- 2 -
1.3.1 Front Panel
and line down maneuvering.
1.3.2 Bottom Connector Panel
The connector panel is located at the lower part of the casing, withholding the socket openings for all external
connections as follows (from left to right):
1. External secondary Reader 2 – for optional external readers
2. External secondary Reader 1 – for optional external readers
3. I2C – I/O Extension (N/A) – not used
4. Network
5. Serial I – Serial port connection for printer (N/A) – not used
6. Host – RS-232 / RS-485 Communications
1.4 Internal Components
The SY-765 has two back-up battery modules, one for the real time clock memory and the other for operation
during a power failure.
The standard memory back-up module is a lithium battery, which will keep the internal clock running and the memory
intact, for 30daysduring a power failure.
The back-up battery provided (in addition to the standard memory back-up) is a self-recharging system which allows
the terminal to operate during a power failure. The battery provides power for one and a half net hours of use. A shut
down timeout feature enables the terminal to operate for more extended periods of time.
The SY-765 Terminal has the following front panel features:
1. 2x16 Character LCD backlit display.
a. The terminal comes with a highly advanced filtered LCD display. This means that under almost any
lighting condition, the terminal will give you a clear picture to read the screen.
2. Two arrow keys are located to the right of the display panel for line up
a. The arrow keys are also used for getting into Technician mode.
3. Eight Function keys located on the left, below the display.
a. [IN], [OUT], [F1], [F2], [F3], and [F4].
4. A numerical keyboard of fourteen keys, including [Enter], [Back Space], [Dot] and [Clear].
5. The Alarm light “!”, is located to the left of the display.
a. The alarm light is an LED that lights when at least half of the memory is used; it blinks when the
memory is almost full.
6. The ON button enables a 15 second manual operation window if the terminal is on battery back-up power.