Syscall NTT Works DT-5020 User manual

User Manual
Please read the user manual carefully
before start using the device.
User Manual
Server Paging Transmitter DT-5020
User Manual

2
Syscall Server Paging Transmitter Manual
Table of contents
Getting Started
1. Components & Specification
2. Installation
3. Description
Functions
4. Functions
4-1. Preset Message Setting
4-2. Channel Number Setting
4-3. Beep & Haptic Feedback Setting
4-4. RF Output Power Control
5. How to Use DT-5020
5-1. How to Call a Direct Pager
5-2. How to Use the Call History
5-3. How to Connect with a Repeater
3
3
4
5
6
6
6
7
7
8

Specification Features
Frequency
Power Source
Dimension
Weight
Color
FSK/433.42MHz
DC 12V/1A
W100 X L177 X H33mm
200g
Black
1. Smart touch keypad
2. Send 4 preset messages up to 99 pagers
3. Alphanumeric messages up to 10 digits
4. Able to check up to 20 call history
3
Syscall Server Paging Transmitter Manual
Components
1. Components & Specification
2. Installation
Transmitter
+ Antenna
(DT-5020)
Power Adapter
(DC 12V/1A)
User Manual
1
Plug the power adapter and insert the connector into the port next to the antenna.
Turn on the power switch on the right side of the transmitter.
Set the same Pn (Channel number) of both DT-5020 and Direct pagers to connect.
*For more details, please refer to Direct pager user manual.
1
2
3
2

Functions
Preset Message Setting
Channel Number Setting
Beep & Haptic Feedback Setting SV 3
RF Output Power Control
-
-
-
-
1~99
0(Beep-OFF, Vibration-OFF)
1(Beep-ON, Vibration-OFF)
2(Beep-OFF, Vibration-ON)
3(Beep-ON, Vibration-ON)
1~2
1
2
3
4
1
2
F1
F2
F3
F4
Pn
RP
RangeDefault
Keypad Description
Display Description
Description of Functions
4
Syscall Server Paging Transmitter Manual
3. Description
Choose preset messages
Menu shift
Cancel/ Exit
Enter the function setting/ Delete
Gn: Last called server number
*Gn keeps changing whenever another server is called
~
Save/ Call
Call history check/
Convert the letter to uppercase or lowercase
Activate the character list
1
1
Gn
Gn
Press F1~F4 key!
Pn
N
*
DT
1
Home Screen Display
Pn: Channel number
Check preset messages
Total number of call history
N
[ 1
/
20]
*
DT
2
Call History Display
Preset messages
Gn: Called server number
03
01
Dessert
Food ready
Clean up
Manager
06
05

*Edit area will be marked on the top
(Touch and hold FUN/DEL for 2 sec to delete all letters)
Maximum of 10 characters can be written.
(Recommend to set ‘A10 Display’ in Display Type Setting of Direct pagers.)
When buzzer beeps and
vibration occurs, enter the
password screen
Touch and hold for 3sec
Tap FUN/DEL to delete the letter
5
Syscall Server Paging Transmitter Manual
4. Functions
4-1. Preset Message Setting [F1~F4]
How to Enter the Function Setting
Touch and hold for 3sec
When buzzer beeps and
vibration occurs, enter the
password screen
Edit each preset message in F1, F2, F3, and F4.
1
1
Gn
Press F1~F4 key!
Pn
N
*
DT
0000
Tap 0000
----
1
1
Gn
Press F1~F4 key!
Pn
N
*
DT
0000
Tap 0000
----
When the function setting is finished, tap to exit from the settings.
1
Pn
1
SV
3
RP
2
N
*
DT
F1
Tap F1/F2/F3/F4 where
the message needs to be edited
Tap * to activate
the character list
Tap 0~9 key to write number
Save
Tap CH to convert the letter
to uppercase or lowercase

6
Syscall Server Paging Transmitter Manual
1
1
Gn
Press F1~F4 key!
Pn
N
*
DT
0000
Tap 0000
----
Set the same Pn (Channel number) of both DT-5020 and Direct pagers to connect.
4-2. Channel Number Setting [Pn]
Move on ‘Pn’
When buzzer beeps and
vibration occurs, enter the
password screen
Food ready
Pn
1
SV
3
RP
2
N
*
DT
F1
Enter the Pn
1
Touch and hold for 3sec
Save
Turn ON/OFF the beep sound & haptics of the transmitter.
4-3. Beep & Haptic Feedback Setting [SV]
Food ready
Pn
1
SV
3
RP
2
N
*
DT
F1
When buzzer beeps and
vibration occurs, enter the
password screen
Touch and hold for 3sec
Save
Move on ‘SV’
Tap
twice
Choose 0~3
30OFF
1Beep
2Vibration
3Beep+
Vibration
1
1
Gn
Press F1~F4 key!
Pn
N
*
DT
0000
Tap 0000
----
Food ready
Pn
1
SV
3
RP
2
N
*
DT
F1
When buzzer beeps and
vibration occurs, enter the
password screen
Touch and hold for 3sec
Save
Move on ‘RP’
Tap
3 times
Set the RF output power
2Range: 1~2
1
1
Gn
Press F1~F4 key!
Pn
N
*
DT
0000
Tap 0000
----
Able to set the RF output power of the transmitter.
4-4. RF Output Power Control [RP]

Caution! Set the same Pn (Channel number) of both DT-5020 and Direct pagers.
5-1. How to Call a Direct Pager
Call history can be stored up to 20 in the list.
5-2. How to Use the Call History
5. How to Use DT-5020 7
Syscall Server Paging Transmitter Manual
N
[ 1
/
20]
*
DT
03
01
Dessert
Food ready
Clean up
Manager
06
05
Call
CALL
CLEAR
Tap CH
Tap CH Clear
Choose a message from F1~F4
1
1
Gn
Food ready
Gn 1-
1
Pn
N
*
DT
1
Enter the server number (Gn)
Call
N
[ 1
/
20]
*
DT
03
01
Dessert
Food ready
Clean up
Manager
06
05
Tap NEXT to move
the Call history list up and down
Tap NEXT to move
the Call history list up and down

+ O
5-3. How to Connect with a Repeater
8
Syscall Server Paging Transmitter Manual
Caution! Please follow the steps below in a row.
1 2
STEP 1. Pn (Channel number) Setting in [d1], SRT-8200
A 1 C 1 1
1
O- +
O
01
STEP 2. Reception mode ON in [d2], SRT-8200
* ‘0’= OFF, ‘1’= ON [Default: 0]
+ O
1
* If repeats all DT-5020 signals, leave it as ‘0’.
* Range: 0~99 [Default: 0]
O
1. Press and hold O for 9sec until “d1” is displayed.
2. Press O to enter the setting mode.
5. Press O for 2sec to save.
1. Press + once and then, press O to enter the setting mode. [d2]
2. Select ‘1’ by pressing + and then, press O for 2sec to save.
3. Move to the next digit by pressing ‒ or +, then press O to enter the Edit mode.
4. Set the same Pn with DT-5020 by pressing ‒ or +.

* ‘0’= OFF, ‘1’= ON [Default: 0]
+ O
1
2+ O
3
* For more details, please refer to SRT-8200 user manual.
9
Syscall Server Paging Transmitter Manual
STEP 3. Repeater mode ON in [d3], SRT-8200
- +
1. Press + once and then, press O to enter the setting mode. [d3]
2. Select ‘1’ by pressing + and then, press O for 2sec to save.
3. Press ‒ or + together to exit from the setting mode.

Memo


■SYSCALL France - www.syscallglobal.fr
0033 (0)1 84 17 61 81 - [email protected]
242 boulevard de Stalingrad 94500 Champigny sur Marne
FRANCE
■NTTWORKS CO., LTD
413-9 NTTWORKS Bldg, Galhyun-Dong, Eunpyong-Gu Seoul
KOREA
Manufacturer
Table of contents