System Sensor PDRP-2001 User manual

E4
P/N 53043:E4 ECN 16-235
Document 53043
7/28/2016 Rev:
3825 Ohio Avenue
St. Charles, IL 60174
1-800-SENSOR2
Fax: (630) 377-6495
PDRP-2001 Series
PRE-ACTION/DELUGE CONTROL PANEL
Instruction Manual

2PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Fire Alarm & Emergency Communication System Limitations
While a life safety system may lower insurance rates, it is not a substitute for life and property insurance!
An automatic fire alarm system—typically made up of smoke
detectors, heat detectors, manual pull stations, audible warning
devices, and a fire alarm control panel (FACP) with remote notifi-
cation capability—can provide early warning of a developing fire.
Such a system, however, does not assure protection against
property damage or loss of life resulting from a fire.
An emergency communication system—typically made up of
an automatic fire alarm system (as described above) and a life
safety communication system that may include an autonomous
control unit (ACU), local operating console (LOC), voice commu-
nication, and other various interoperable communication meth-
ods—can broadcast a mass notification message. Such a
system, however, does not assure protection against property
damage or loss of life resulting from a fire or life safety event.
The Manufacturer recommends that smoke and/or heat
detectors be located throughout a protected premises following
the recommendations of the current edition of the National Fire
Protection Association Standard 72 (NFPA 72), manufacturer's
recommendations, State and local codes, and the
recommendations contained in the Guide for Proper Use of
System Smoke Detectors, which is made available at no charge
to all installing dealers. This document can be found at http://
www.systemsensor.com/appguides/. A study by the Federal
Emergency Management Agency (an agency of the United
States government) indicated that smoke detectors may not go
off in as many as 35% of all fires. While fire alarm systems are
designed to provide early warning against fire, they do not
guarantee warning or protection against fire. A fire alarm system
may not provide timely or adequate warning, or simply may not
function, for a variety of reasons:
Smoke detectors may not sense fire where smoke cannot
reach the detectors such as in chimneys, in or behind walls, on
roofs, or on the other side of closed doors. Smoke detectors
also may not sense a fire on another level or floor of a building.
A second-floor detector, for example, may not sense a first-floor
or basement fire.
Particles of combustion or “smoke” from a developing fire
may not reach the sensing chambers of smoke detectors
because:
• Barriers such as closed or partially closed doors, walls, chim-
neys, even wet or humid areas may inhibit particle or smoke
flow.
• Smoke particles may become “cold,” stratify, and not reach
the ceiling or upper walls where detectors are located.
• Smoke particles may be blown away from detectors by air
outlets, such as air conditioning vents.
• Smoke particles may be drawn into air returns before reach-
ing the detector.
The amount of “smoke” present may be insufficient to alarm
smoke detectors. Smoke detectors are designed to alarm at var-
ious levels of smoke density. If such density levels are not cre-
ated by a developing fire at the location of detectors, the
detectors will not go into alarm.
Smoke detectors, even when working properly, have sensing
limitations. Detectors that have photoelectronic sensing cham-
bers tend to detect smoldering fires better than flaming fires,
which have little visible smoke. Detectors that have ionizing-type
sensing chambers tend to detect fast-flaming fires better than
smoldering fires. Because fires develop in different ways and
are often unpredictable in their growth, neither type of detector is
necessarily best and a given type of detector may not provide
adequate warning of a fire.
Smoke detectors cannot be expected to provide adequate warn-
ing of fires caused by arson, children playing with matches
(especially in bedrooms), smoking in bed, and violent explosions
(caused by escaping gas, improper storage of flammable materi-
als, etc.).
Heat detectors do not sense particles of combustion and alarm
only when heat on their sensors increases at a predetermined
rate or reaches a predetermined level. Rate-of-rise heat detec-
tors may be subject to reduced sensitivity over time. For this
reason, the rate-of-rise feature of each detector should be tested
at least once per year by a qualified fire protection specialist.
Heat detectors are designed to protect property, not life.
IMPORTANT! Smoke detectors must be installed in the same
room as the control panel and in rooms used by the system for
the connection of alarm transmission wiring, communications,
signaling, and/or power. If detectors are not so located, a devel-
oping fire may damage the alarm system, compromising its abil-
ity to report a fire.
Audible warning devices such as bells, horns, strobes,
speakers and displays may not alert people if these devices
are located on the other side of closed or partly open doors or
are located on another floor of a building. Any warning device
may fail to alert people with a disability or those who have
recently consumed drugs, alcohol, or medication. Please note
that:
• An emergency communication system may take priority over
a fire alarm system in the event of a life safety emergency.
• Voice messaging systems must be designed to meet intelligi-
bility requirements as defined by NFPA, local codes, and
Authorities Having Jurisdiction (AHJ).
• Language and instructional requirements must be clearly dis-
seminated on any local displays.
• Strobes can, under certain circumstances, cause seizures in
people with conditions such as epilepsy.
• Studies have shown that certain people, even when they hear
a fire alarm signal, do not respond to or comprehend the
meaning of the signal. Audible devices, such as horns and
bells, can have different tonal patterns and frequencies. It is
the property owner's responsibility to conduct fire drills and
other training exercises to make people aware of fire alarm
signals and instruct them on the proper reaction to alarm sig-
nals.
• In rare instances, the sounding of a warning device can cause
temporary or permanent hearing loss.
A life safety system will not operate without any electrical
power. If AC power fails, the system will operate from standby
batteries only for a specified time and only if the batteries have
been properly maintained and replaced regularly.
Equipment used in the system may not be technically compat-
ible with the control panel. It is essential to use only equipment
listed for service with your control panel.
Telephone lines needed to transmit alarm signals from a prem-
ises to a central monitoring station may be out of service or tem-
porarily disabled. For added protection against telephone line
failure, backup radio transmission systems are recommended.
The most common cause of life safety system malfunction is
inadequate maintenance. To keep the entire life safety system in
excellent working order, ongoing maintenance is required per the
manufacturer's recommendations, and UL and NFPA stan-
dards. At a minimum, the requirements of NFPA 72 shall be fol-
lowed. Environments with large amounts of dust, dirt, or high air
velocity require more frequent maintenance. A maintenance
agreement should be arranged through the local manufacturer's
representative. Maintenance should be scheduled monthly or as
required by National and/or local fire codes and should be per-
formed by authorized professional life safety system installers
only. Adequate written records of all inspections should be kept.
Limit-D-1-2013

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 3
Installation Precautions
Adherence to the following will aid in problem-free installation with long-term reliability:
WARNING - Several different sources of power can be
connected to the fire alarm control panel. Disconnect all
sources of power before servicing. Control unit and associ-
ated equipment may be damaged by removing and/or insert-
ing cards, modules, or interconnecting cables while the unit is
energized. Do not attempt to install, service, or operate this
unit until manuals are read and understood.
CAUTION - System Re-acceptance Test after Software
Changes: To ensure proper system operation, this product
must be tested in accordance with NFPA 72 after any pro-
gramming operation or change in site-specific software. Re-
acceptance testing is required after any change, addition or
deletion of system components, or after any modification,
repair or adjustment to system hardware or wiring. All compo-
nents, circuits, system operations, or software functions known
to be affected by a change must be 100% tested. In addition,
to ensure that other operations are not inadvertently affected,
at least 10% of initiating devices that are not directly affected
by the change, up to a maximum of 50 devices, must also be
tested and proper system operation verified.
This system meets NFPA requirements for operation at 0-49º
C/32-120º F and at a relative humidity 93% ± 2% RH (non-
condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful
life of the system's standby batteries and the electronic com-
ponents may be adversely affected by extreme temperature
ranges and humidity. Therefore, it is recommended that this
system and its peripherals be installed in an environment with
a normal room temperature of 15-27º C/60-80º F.
Verify that wire sizes are adequate for all initiating and indi-
cating device loops. Most devices cannot tolerate more than a
10% I.R. drop from the specified device voltage.
Like all solid state electronic devices, this system may
operate erratically or can be damaged when subjected to light-
ning induced transients. Although no system is completely
immune from lightning transients and interference, proper
grounding will reduce susceptibility. Overhead or outside aerial
wiring is not recommended, due to an increased susceptibility
to nearby lightning strikes. Consult with the Technical Ser-
vices Department if any problems are anticipated or encoun-
tered.
Disconnect AC power and batteries prior to removing or
inserting circuit boards. Failure to do so can damage circuits.
Remove all electronic assemblies prior to any drilling, filing,
reaming, or punching of the enclosure. When possible, make
all cable entries from the sides or rear. Before making modifi-
cations, verify that they will not interfere with battery, trans-
former, or printed circuit board location.
Do not tighten screw terminals more than 9 in-lbs. Over-
tightening may damage threads, resulting in reduced terminal
contact pressure and difficulty with screw terminal removal.
This system contains static-sensitive components.
Always ground yourself with a proper wrist strap before han-
dling any circuits so that static charges are removed from the
body. Use static suppressive packaging to protect electronic
assemblies removed from the unit.
Follow the instructions in the installation, operating, and pro-
gramming manuals. These instructions must be followed to
avoid damage to the control panel and associated equipment.
FACP operation and reliability depend upon proper installation.
Precau-D1-9-2005
FCC Warning
WARNING: This equipment generates, uses, and can
radiate radio frequency energy and if not installed and
used in accordance with the instruction manual may
cause interference to radio communications. It has been
tested and found to comply with the limits for class A
computing devices pursuant to Subpart B of Part 15 of
FCC Rules, which is designed to provide reasonable
protection against such interference when devices are
operated in a commercial environment. Operation of this
equipment in a residential area is likely to cause interfer-
ence, in which case the user will be required to correct
the interference at his or her own expense.
Canadian Requirements
This digital apparatus does not exceed the Class A limits
for radiation noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Cana-
dian Department of Communications.
Le present appareil numerique n'emet pas de bruits radi-
oelectriques depassant les limites applicables aux appa-
reils numeriques de la classe A prescrites dans le
Reglement sur le brouillage radioelectrique edicte par le
ministere des Communications du Canada.
Acclimate®, SpectrAlert®, and System Sensor® are all registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered
trademarks of the Microsoft Corporation. Chrome™ and Google™ are trademarks of Google Inc.
©2016 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.

4PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Software Downloads
In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make
frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest
features, we strongly recommend that you download the most current version of software for each product prior to
commissioning any system. Contact Technical Support with any questions about software and the appropriate version for a
specific application.
Documentation Feedback
Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about our
online Help or printed manuals, you can email us.
Please include the following information:
•Product name and version number (if applicable)
•Printed manual or online Help
•Topic Title (for online Help)
•Page number (for printed manual)
•Brief description of content you think should be improved or corrected
•Your suggestion for how to correct/improve documentation
Send email messages to:
FireSystems.T[email protected]
Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical
Services.

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 5
Table of Contents
Section 1: Product Description .............................................................................................12
1.1: Product Features ..........................................................................................................................................12
1.2: Specifications...............................................................................................................................................13
1.3: Controls and Indicators................................................................................................................................16
1.4: Components .................................................................................................................................................17
1.5: Optional Modules and Accessories .............................................................................................................17
Section 2: Installation............................................................................................................. 19
2.1: Backbox Mounting ......................................................................................................................................19
2.2: Operating Power ..........................................................................................................................................22
2.3: Input Circuits ...............................................................................................................................................24
2.4: Output Circuits.............................................................................................................................................26
2.4.1: Outputs/Notification Appliance/Releasing Circuits ..........................................................................26
2.4.2: Special Application DC Power Output Connections.........................................................................27
2.4.3: Relays - Programmable .....................................................................................................................27
2.5: Power-limited Wiring Requirements ...........................................................................................................28
2.6: Installation of Optional Modules .................................................................................................................29
2.6.1: CAC-5X Class A Converter Module.................................................................................................29
Installation ............................................................................................................................................29
Wiring NACs and IDCs for Class A ....................................................................................................30
2.6.2: 4XTMF Municipal Box Transmitter Option Module........................................................................31
4XTMF Transmitter Module Installation............................................................................................31
2.6.3: ANN-SEC Option Card.....................................................................................................................33
2.7: ANN-BUS Devices......................................................................................................................................33
Guidelines.............................................................................................................................................33
2.7.1: ANN-BUS Wiring .............................................................................................................................34
Calculating Wiring Distance for ANN-BUS Modules.........................................................................34
Wiring Configuration ...........................................................................................................................36
Powering ANN-BUS Devices from Auxiliary Power Supply .............................................................36
2.7.2: ANN-BUS Device Addressing..........................................................................................................37
2.7.3: ANN-80 Remote LCD Annunciator..................................................................................................37
Specifications .......................................................................................................................................37
Installation ............................................................................................................................................37
Wiring ANN-80 to FACP.....................................................................................................................38
2.7.4: ANN-S/PG Serial/Parallel Printer Interface Installation...................................................................39
Specifications .......................................................................................................................................40
PRN-7 Printer Installation ....................................................................................................................40
PRN-6F Printer Installation..................................................................................................................41
2.7.5: ANN-I/O LED Driver Module ..........................................................................................................42
ANN-I/O Board Layout........................................................................................................................43
Specifications .......................................................................................................................................43
ANN-I/O Connection to FACP ............................................................................................................44
ANN-I/O Module LED Wiring ............................................................................................................44
2.7.6: ANN-LED Annunciator Module .......................................................................................................45
Specifications .......................................................................................................................................45
Mounting/Installation ...........................................................................................................................45
ANN-LED Board Layout and Connection to FACP............................................................................46
2.7.7: ANN-RLY Relay Module .................................................................................................................46
Specifications .......................................................................................................................................46
Mounting/Installation ...........................................................................................................................47
ANN-RLY Board Layout and Connection to FACP............................................................................47
Section 3: Programming ........................................................................................................48
3.1: User Programming.......................................................................................................................................48
3.2: Initial Power-up ...........................................................................................................................................49

Table of Contents
6PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
3.3: Programming Screens Description ..............................................................................................................49
3.4: Programming and Passwords.......................................................................................................................50
3.5: Master Programming Level .........................................................................................................................51
3.5.1: FACP CONFIG (Application Templates) .........................................................................................51
3.5.2: Input Zones ........................................................................................................................................52
3.5.3: Output Circuits...................................................................................................................................56
Enabled .................................................................................................................................................56
Type ......................................................................................................................................................56
Silence...................................................................................................................................................57
Auto Silence..........................................................................................................................................58
Silence Inhibited ...................................................................................................................................58
Coding ..................................................................................................................................................58
3.5.4: Cross Input Zones ..............................................................................................................................60
3.5.5: On-Board Relays ...............................................................................................................................60
3.5.6: System Setup .....................................................................................................................................61
Timers...................................................................................................................................................62
Banner...................................................................................................................................................63
Time-Date.............................................................................................................................................64
Trouble Reminder.................................................................................................................................65
Charger Disable ....................................................................................................................................65
Canadian Option ...................................................................................................................................66
Secondary ANN-BUS Option...............................................................................................................66
3.5.7: ANN-BUS..........................................................................................................................................66
ANN-BUS Enabled ..............................................................................................................................66
ANN-BUS Modules..............................................................................................................................67
Auto-Configure.....................................................................................................................................67
ANN-S/PG Options ..............................................................................................................................67
ANN-I/O LED Zone Assignments .......................................................................................................68
ANN-80 Options...................................................................................................................................69
ANN-RLY Options...............................................................................................................................69
3.5.8: History ...............................................................................................................................................70
View Events..........................................................................................................................................70
Erase History ........................................................................................................................................71
3.5.9: Walktest .............................................................................................................................................71
3.5.10: Clear Program..................................................................................................................................72
3.5.11: Password Change.............................................................................................................................72
3.6: Maintenance Programming Level................................................................................................................72
3.6.1: Input Zones - Enable/Disable ............................................................................................................73
3.6.2: History ...............................................................................................................................................73
3.6.3: Walktest .............................................................................................................................................74
3.6.4: Time-Date ..........................................................................................................................................74
Section 4: Operating Instructions ......................................................................................... 76
4.1: Panel Control Buttons ..................................................................................................................................76
4.1.1: Acknowledge/Step.............................................................................................................................76
4.1.2: Alarm Silenced (Domestic/Export Versions)/Signal Silence (Canadian Version)............................76
4.1.3: Drill/Hold 2 Sec (Domestic/Export Versions)/Alarm Signal (Canadian Version)............................76
4.1.4: Reset ..................................................................................................................................................76
4.2: Indicators......................................................................................................................................................77
4.3: Normal Operation ........................................................................................................................................77
4.4: Trouble Operation ........................................................................................................................................78
4.5: Alarm Operation ..........................................................................................................................................79
4.6: Supervisory Operation .................................................................................................................................80
4.7: Disable/Enable Operation ............................................................................................................................80
4.8: Waterflow Circuits Operation ......................................................................................................................80
4.9: 2nd-Shot Water Switch ................................................................................................................................81
4.10: Detector Functions .....................................................................................................................................81

Table of Contents
PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 7
4.11: Coded NAC Operation...............................................................................................................................81
4.12: Release Stages............................................................................................................................................81
4.13: Special System Timers...............................................................................................................................82
4.13.1: Silence Inhibit Timer.......................................................................................................................82
4.13.2: Autosilence Timer ...........................................................................................................................82
4.13.3: Trouble Reminder............................................................................................................................82
4.13.4: Soak Timers.....................................................................................................................................82
4.13.5: Waterflow Delay Timer...................................................................................................................82
4.14: Walktest .....................................................................................................................................................82
4.15: Read Status ................................................................................................................................................83
4.15.1: FACP Configuration........................................................................................................................83
4.15.2: Input Zones......................................................................................................................................84
4.15.3: Output Circuits ................................................................................................................................84
4.15.4: Cross Input Zones............................................................................................................................84
4.15.5: On-Board Relays .............................................................................................................................85
4.15.6: System Settings ...............................................................................................................................85
4.15.7: Timers..............................................................................................................................................85
4.15.8: Daylight Savings .............................................................................................................................85
4.15.9: History .............................................................................................................................................86
4.15.10: Print ...............................................................................................................................................86
4.15.11: ANN-BUS .....................................................................................................................................86
Section 5: Power Supply Calculations..................................................................................87
5.1: Overview......................................................................................................................................................87
5.2: Calculating the AC Branch Circuit..............................................................................................................87
5.3: Calculating the System Current Draw .........................................................................................................88
5.3.1: Overview ...........................................................................................................................................88
5.3.2: How to Use Table 5.3 on page 89 to Calculate System Current Draw .............................................88
5.4: Calculating the Battery Size ........................................................................................................................90
5.4.1: NFPA Battery Requirements .............................................................................................................90
5.4.2: Selecting and Locating Batteries .......................................................................................................90
Appendix A: Circuit Mapping and Cross-Zoning.................................................................91
A.1: Input-to-Output Circuit Mapping and Cross-Zone Operation ....................................................................91
A.1.1: Mapping Input Zones to Output Circuits for Direct Activation .......................................................92
A.1.2: Mapping Input Zones to Release Circuits for Cross Zone Activation..............................................93
A.1.3: Complex Examples of Cross Zoning and I/O Mapping for Release Circuits...................................95
Appendix B: FACP Configuration Templates.......................................................................96
B.1: Template 1: Single Hazard - 3 Zone ...........................................................................................................97
B.2: Template 2: Single Hazard - Cross-Zone With Manual Release ................................................................99
B.3: Template 3: Dual Hazard - Combined Release .........................................................................................101
B.4: Template 4: Dual Hazard - Split Release ..................................................................................................103
B.5: Template 5: Single Hazard - 3 Zones and Low Pressure ..........................................................................105
B.6: Template 6: Single Hazard - 2 Zones Cross-Zoned With All Active........................................................107
B.7: Template 7: Single Hazard - Dual Zone....................................................................................................109
Appendix C: NFPA Standard-Specific Requirements .......................................................111
C.1: NFPA 72 Auxiliary Fire Alarm System ....................................................................................................114
C.2: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts....................................117
Appendix D: FACP with Keltron ..........................................................................................118
Appendix E: Testing & Maintenance...................................................................................119
E.1: Testing .......................................................................................................................................................119
E.1.1: Inspection ........................................................................................................................................119
E.1.2: Alarm Test.......................................................................................................................................119
E.1.3: Detector Testing..............................................................................................................................119
E.2: Maintenance ..............................................................................................................................................120

Table of Contents
8PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Appendix F: Wire Requirements ......................................................................................... 121
F.1: NAC Wiring ...............................................................................................................................................122
Index ...................................................................................................................................... 123
PDRP-2001, PDRP-2001E, PDRP-2001C
PRE-ACTION/DELUGE CONTROL PANEL
Operating Instructions ......................................................................................................... 129

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 9
It is imperative that the installer understand the requirements of the Authority Having Jurisdiction
(AHJ) and be familiar with the standards set forth by the following regulatory agencies:
• Underwriters Laboratories
• NFPA 72 National Fire Alarm Code
• CAN/ULC - S527-11 Standard for Control Units for Fire Alarm Systems
NFPA Standards
This Fire Alarm Control Panel complies with the following NFPA Standards:
NFPA 13 Installation of Sprinkler Systems
NFPA 15 Water Spray Fixed Systems
NFPA 16 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems
NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station
Fire Alarm Systems (requires an optional Remote Station Output Module)
Underwriters Laboratories Documents for Reference:
UL 38 Manually Actuated Signaling Boxes
UL 217 Smoke Detectors, Single and Multiple Station
UL 228 Door Closers–Holders for Fire Protective Signaling Systems
UL 268 Smoke Detectors for Fire Protective Signaling Systems
UL 268A Smoke Detectors for Duct Applications
UL 346 Waterflow Indicators for Fire Protective Signaling Systems
UL 464 Audible Signaling Appliances
UL 521 Heat Detectors for Fire Protective Signaling Systems
UL 864 Standard for Control Units for Fire Protective Signaling Systems
UL 1481 Power Supplies for Fire Protective Signaling Systems
UL 1638 Visual Signaling Appliances
UL 1971 Signaling Devices for Hearing Impaired
CAN/ULC - S524-01 Standard for Installation of Fire Alarm Systems
This Class (A) digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe (A) est conforme à la norme NMB-003 du Canada.
Other:
Canadian Electrical Code, Part I
NEC Article 250 Grounding
NEC Article 300 Wiring Methods
NEC Article 760 Fire Protective Signaling Systems
Applicable Local and State Building Codes
Requirements of the Local Authority Having Jurisdiction (LAHJ)
Documents
411UD Manual Document #50759
411UDAC Manual Document #51073
CHG-75 Battery Charger Manual Document #51315
CHG-120 Battery Charger Manual Document #50888
ANN-80 Product Installation Doc. Document #52749
ANN-(R)LED Product Installation Doc. Document #53032
ANN-I/O Product Installation Doc. Document #151416
ANN-RLY Product Installation Doc. Document #53033
ANN-S/PG Product Installation Doc. Document #151417
This product has been certified to comply with the requirements in the Standard for Control Units and Accessories for Fire
Alarm Systems, UL 864, 9th Edition. Operation of this product with products not tested for UL 864, 9th Edition has not
been evaluated. Such operation requires the approval of the local Authority Having Jurisdiction (AHJ).
This product has been certified to comply with the requirements in the Standard for Control Units for Fire Alarm Systems,
ULC-S527, 3rd Edition. Operation of this product with products not tested for ULC-S527 3rd Edition has not been
evaluated. Such operation requires the approval of the local Authority Having Jurisdiction (AHJ).
Before proceeding, the installer should be familiar with the following documents.

10 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Main Circuit Board
6
6
TB6
ZONE
6
SW1
T
B
4
/
T
B
6
1
/
6
2
3
5
4
AAAA
Dummy load all unused circuits
with 4.7KΩ, ½ watt End-of-Line
resistors
Style Z (Class A) NAC
Style D (Class A) IDC
CAC-5X
Class A Converter Module
3 Programmable Relays
Nonsupervised relay contacts
Contact Ratings
2.0 amps @ 30 VDC (resistive)
0.5 amp @ 30 VAC (resistive)
Contacts shown below in normal
condition (AC power with no alarm,
trouble, or supervisory activity)
A Fail Safe Trouble relay
switches to the NC position
during trouble conditions and
under loss of all power.
(*Factory default relay programming)
Alarm* Trouble* Supervisory*
Class A Converter Module
Remove jumper JP43 to
disable Ground Fault
Detection circuit (only with
approval of AHJ)
Cut this jumper to supervise
the 4XTM module when
installed (see J4 & J5)
Cut this jumper to
enable Supervisory
Relay when 4XTMF
module is installed
Auxiliary
Trouble Input
Kiss-off LED
ANN-SEC
option card connector
Battery
24 VDC, supervised,
nonpower-limited
26 Amp Hour maximum
Basic System Connections
Power Supply Connector
For more specific UL wiring
information, refer to page 28.
Important! Removing Ground Fault Disable
Jumper JP43 voids UL/NFPA Style/Class
indentifications for circuits. Remove jumper
JP43 only with the approval of the local AHJ
(Authority Having Jurisdiction).
Special Application
DC Power Outputs 24 VDC)
Nonsupervised, power-limited circuits
Supervise with a power supervision relay
EOLR-1
Resettable Power - 24 VDC filtered,
power-limited, Class 2 (0.5 amp
maximum) to smoke detectors (IDC).
Supervise with power supervision
relay EOLR-1.
Nonresettable or Resettable Power
Jumper selectable by JP31, 24 VDC
filtered, power-limited, Class 2 (0.5 amp
maximum). Supervise with power
supvervision relay EOLR-1. Nonresettable
Power suitable for powering smoke
detectors.
Configure TB9, Terminals 1 & 2 as
Resettable or Nonresettable Power.
• Resettable Power - jumper JP31 pins 2
& 3
• Nonresettable Power - jumper JP31 pins
1 & 2 (as shown)
4
3
2
1
{
{
Output Circuit #1
NAC
Output Circuit
#3 NAC
Push switch down to
upgrade software
IDCs 1 through 6, Style B (Class B) (Supervised,
Power-Limited, Class 2) (See Style D illustrated
near right edge of board.)
4.7Kohm, ½ watt End-of-Line Resistor PN 71252
Initiating Device Circuits
rp2001layout.wmf
Normally
Open
Waterflow
Devices or
Pressure
Switches
Input IDC
Waterflow
Circuit #6
Output Circuits - TB5 & TB7
Special Application Power
In this example NAC Output Circuits #1, #3, & #4, Style Y (Class B) (Supervised,
Power-Limited, Class 2) NAC Output Circuit #2 (Releasing) is Style Y (Class B)
(Supervised, Nonpower-Limited, Class 1) 3.0 amp max. per circuit. (See Style Z
illustrated near right edge of board.)
4.7Kohm, ½ watt End-of-Line Resistor PN 71252
Output
Circuit #2
Releasing
Input IDC
Circuit #1
polarized
bell
polarized
strobe
polarized
horn
smoke
detector
pull
station
heat
detector
manual
release
Normally
Open
Tamper
or
Pressure
Switches
Input IDC
Supervisory
Circuit #5
Output
Circuit
#4

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 11
-
+
-
+
JP1
JP3
SW1
JP4
TB3
TB4
TB2
ENABLE
AC DELAY
16 HR
DELAY
TENS
ONES
CUT FOR
240VAC
GND FLT
DISABLE
AM-1 ENABLE
ADDRESS
ON OFF
AM-1
JP5
JP2
F1 F2
J4
J1 J2 J3
F3
TB1
HOT
OUT
+
BAT
+ OUT
-
BAT
-
EARTH
NEUT
1
5
1
5
A- B- A+ B+
NC NO C
0
4
3
9
2
6
1
5
7
8
12
13
15
14
10
11
0
4
3
9
2
6
1
5
7
8
12
13
15
14
10
11
T
B
1
TBL
J1
J2
7 6 5 1
POWER LI MITED
Sw1
P1 P2 P3 P4
110
11 20 21 30 31 40
1
2
3
4
5
ALARM
TROUBLE
FIRE ALARM ANNUNCIATOR
A
C
K
S
T
E
P
TB1
J1
SW1
JP2
ANN-BUS
1 2 3 4 5 6 7 8
TB6
TB3
TB5
TB4
TB2
Alarm
Silenced
Earth
Fault
ZONE1
ALM
TBL
SUP
1
ZONE6
ALM
TBL
SUP
6
NAC1
Fault
Battery
Fault
ZONE 2
ALM
TBL
SUP
2
ZONE 7
ALM
TBL
SUP
7
NAC2
Fault
Charger
Fault
ZONE3
ALM
TBL
SUP
3
ZONE8
ALM
TBL
SUP
8
FIRE ALARM ANNUNCIATOR
NAC 4
Fault
ZONE 5
ALM
TBL
SUP
5
ALM
TBL
SUP
NAC 3
Fault
Disabled
ZONE4
ALM
TBL
SUP
4
ZONE9
ALM
TBL
SUP
9
CHG-120F Charger
Doc. #50888
ANN-BUS - TB3
Battery Connector - J12
rp-peri.wmf
ANN-80
LCD Text Annunciator
Doc. #52749
ANN-I/O
LED Driver
Doc. #151416
ANN-S/PG
Printer Driver
Doc. #151417
CHG-75 Charger
Doc. # 51315
ANN-(R)LED
LED Display
Doc. #53032
ANN-RLY
10 Form-C Relay Card
Doc. #53033
4XTM
Reverse Polarity Module
J4 & J5

12 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Section 1: Product Description
The PDRP-2001 is a six zone FACP for single and dual hazard deluge and preaction applications.
The FACP provides reliable fire detection, signaling and protection for commercial, industrial and
institutional buildings requiring water-based releasing. The FACP is compatible with System
Sensor’s i3detectors which are conventional smoke detectors that can transmit a maintenance
trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when
the ambient temperature falls below the detector rating of approximately 45oF (7o C) (refer to
System Sensor for i3Installation and Maintenance Instructions). In addition, the control panel is
compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke
detectors, pull stations, waterflow devices, tamper switches and other normally-open contact
devices. Refer to Device Compatibility Appendix for a complete listing of compatible devices.
Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing solenoids.
Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory)
and 24 VDC special application resettable and nonresettable power outputs are also included on the
main circuit board. The FACP supervises all wiring, AC voltage, battery charger and battery level.
Activation of a compatible smoke detector or any normally-open fire alarm initiating device will
activate audible and visual signaling devices, illuminate an indicator, display alarm information on
the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate
an optional module used to notify a remote station or initiate an auxiliary control function.
The PDRP-2001C (Canada) is a ULC approved Canadian version of the FACP which offers the
same features as the PDRP-2001 but is supplied standard with a dress panel and one built-in
ANN-LED annunciator.
The PDRP-2001E offers the same features as the PDRP-2001 but allows connection to 220/240
VA C .
Unless otherwise specified, the information in this manual applies to all versions of the panel.
1.1 Product Features
• Six programmable Style B (Class B) IDCs (Initiating Device Circuit)
• Four programmable Style Y (Class B) output circuits - (special application power)
• Three programmable Form-C relays
• 7.0 amps total 24 VDC output circuit current
• Resettable and non-resettable output power
• Built-in Programmer
• ANN-BUS for connection to optional:
ANN-80 Remote LCD Annunciator
ANN-I/O LED Driver
ANN-S/PG Printer Module
ANN-RLY Relay Module
ANN-LED Annunciator Module
• 80-character LCD display (backlit)
• Real-time clock/calendar with daylight savings time control
• History log with 256 event storage
• Control Buttons
ACK (Acknowledge)
Alarm Silenced
System Reset/Lamp Test
Drill

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 13
Specifications Product Description
• Indicators
Fire Alarm
Supervisory
Trouble
AC Power
Alarm Silenced
Discharge
• Piezo sounder for alarm, trouble and supervisory
• 24 volt operation
• Low AC voltage sense
• Outputs Programmable for:
Releasing Solenoids
NACs programmable for:
– Silence Inhibit
– Auto-Silence
– Strobe Synchronization (System Sensor, Wheelock, Gentex, Faraday, Amseco)
– Selective Silence (horn-strobe mute)
– Temporal or Steady Signal
– Silenceable or Nonsilenceable
– Release Stage Sounder
• Designed for sprinkler standards NFPA 13, 15 and 16
• Disable/Enable control per input zone and output zone
• Extensive transient protection
• Dual hazard operation
• Adjustable waterflow discharge timer and two soak timers
• Cross-zone (double-interlock) capability
• Pre-programmed and custom application templates
• Automatic battery charger with charger supervision
• Silent or audible walktest capabilities
• Optional Dress Panel DP-51050 (red)
• A modified Dress Panel is provided standard with Canadian models: includes an ANN-LED
Annunciator module
• Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet
• Optional CAC-5X Class A Converter Module for Outputs and IDCs
• Optional 4XTMF Municipal Box Transmitter Module
• Optional Digital Alarm Communicators (411, 411UD, 411UDAC)
• Optional ANN-SEC card for secondary ANN-BUS
1.2 Specifications
AC Power
PDRP-2001/C: 120 VAC, 60 Hz, 3.66 amps
PDRP-2001E: 240 VAC, 50 Hz, 2.085 amps
Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation
Supervised, nonpower-limited

14 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Product Description Specifications
Battery (sealed lead acid only) - J12
Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp
Supervised, nonpower-limited
Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in
the FACP cabinet.Larger batteries require a separate battery box such as the BB-26 or BB-55F and
the CHG-75 or CHG-120F Battery Charger.)
Minimum Battery Size: 7 Amp Hour
Canadian Applications
Minimum Battery Size: 12 Amp Hour
Maximum Battery Size: 18 Amp Hour
Initiating Device Circuits - TB4 and TB6
Alarm Zones 1 - 5 on TB 4
Alarm Zone 6 on TB6
Supervised and power-limited circuitry
Operation: All zones Style B (Class B)
Normal Operating Voltage: Nominal 20 VDC
Alarm Current: 15 mA minimum
Short Circuit Current: 40 mA max.
Maximum Loop Resistance: 100 ohms (700 ohms for linear heat detection - See Section 2.3, “Input
Circuits” for more information.)
End-of-Line Resistor: 4.7KΩ, 1/2 watt (Part #71252)
Standby Current: 2 mA
Refer to the Device Compatibility Appendix for listed compatible devices
Notification Appliance and Releasing Circuit(s) - TB5 and TB7
Four Output Circuits
Operation: Style Y (Class B)
Special Application power
Supervised and power-limited circuitry
Normal Operating Voltage: Nominal 24 VDC
Maximum Signaling Current: 7.0 amps (3.0 amps special application, 300 mA regulated maximum
per NAC)
End-of-Line Resistor: 4.7KΩ, 1/2 watt (Part #71252)
Refer to “Wire Requirements” on page 121 for wire specifications
Refer to the Device Compatibility Appendix for compatible listed devices
Form-C Relays - Programmable - TB8
Relay 1 (factory default programmed as Alarm Relay)
Relay 2 (factory default programmed as fail-safe Trouble Relay)
Relay 3 (factory default programmed as Supervisory Relay)
Relay Contact Ratings: 2 amps @ 30 VDC (resistive) and 0.5 amps @ 30 VAC (resistive)
Auxiliary Trouble Input - J6
The Auxiliary Trouble Input is an open collector, unsupervised circuit which can be used to
monitor external devices for trouble conditions. It can be connected to the trouble bus of a
peripheral, such as a power supply, which is compatible with open collector circuits.
All connections must be in conduit, less than 20 ft. (610 cm) in length in the same room.
Special Application Resettable Power - TB9
Operating Voltage: Nominal 24 VDC
Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors
Power-limited Circuitry
Refer to the Device Compatibility Appendix for compatible listed devices

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 15
Specifications Product Description
Special Application Resettable or Nonresettable Power - TB9
Operating Voltage: Nominal 24 VDC
Maximum Available Current: 500 mA
Power-limited Circuitry
Jumper selectable by JP31 for resettable or nonresettable power:
Jumper pins 1 & 2 on JP31 for nonresettable power
Jumper pins 2 & 3 on JP31 for resettable power
Refer to the Device Compatibility Appendix for compatible listed devices
Special Application Primary ANN-BUS Power - TB3
Operating voltage: Nominal 24 VDC
Maximum Available Current: 500 mA
Power-limited circuit
Special Application Secondary ANN-BUS Power - ANN-SEC - TB1
Operating voltage: Nominal 24 VDC
Maximum Available Current: 500 mA
Power-limited circuit
The following figure illustrates the maximum current that is possible for each major panel output
circuit and the total current available from the FACP with the FLPS-7 power supply.
TB9
TB5
TB7
TB3
TB1
Figure 1.1 Current Availability
powerdistmrp.wmf
Refer to the battery calculations
section for additional information.
Standby
1.0 amp max
per panel
Special Application
Nonresettable or
Resettable Power
Special Application
Resettable Power
NAC #1
NAC #2
NAC #3
NAC #4
0.5 amp max
per circuit
0.5 amp max
per circuit
3.0 amps max
per circuit
3.0 amps max
per circuit
3.0 amps max
per circuit
3.0 amps max
per circuit
Alarm
7.0 amps
max
per panel
Primary
ANN-BUS
Standby
1.0 amp max
per panel
0.5 amp max
per circuit
0.5 amp max
per circuit
ANN-SEC
Option Card

16 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Product Description Controls and Indicators
1.3 Controls and Indicators
LCD Display
The FACP uses an 80-character (4 lines X 20 characters) high viewing angle LCD display. The
display includes a long life LED backlight that remains illuminated. If AC power is lost and the
system is not in alarm, the LED backlight will turn off to conserve batteries.
Key Panel
Mounted on the main circuit board, the key panel includes a window for the LCD display and
indicators as listed above. The key panel, which is visible with the cabinet door closed, has 25 keys,
including a 16 key alpha-numeric pad similar to a telephone keypad.
Function keys:
• Acknowledge/Step
• Alarm Silenced (Domestic/Export version)/Signal Silence (Canadian version)
• Drill (Domestic/Export version)/Alarm Signal (Canadian version)
• System Reset (lamp test)
Service/program keys:
• Keys labeled 1 to 9
• * key
• # key
• 0 (recall) key
• 1st Event key
• Clear key
• Escape key
• Mode key
• Four cursor keys (up, down, left and right)
• Enter key
Local Piezo Sounder
A piezo sounder provides separate and distinct pulse rates for alarm, trouble and supervisory
conditions.
Indicators
Indicators are provided to annunciate the following conditions:
• Fire Alarm - red indicator
11
2
3
4
5
6
7
8
9
0
ABC DEF
GHI
-/.
ESC
JKL
SIGNAL
SILENCE
ENTER
TROUBLE
ALARM SILENCED
SUPERVISORY
AC POWER FIRE ALARM
PRE-DISCHARGE DISCHARGE
A
B
O
R
T
11
2
3
4
5
6
7
8
9
0
ABC DEF
GHI
-/.
ESC
JKL
ALARM
SILENCED
ENTER
TROUBLE
ALARM SILENCED
SUPERVISORY
AC POWER FIRE ALARM
PRE-DISCHARGE DISCHARGE
A
B
O
R
T
Figure 1.2 Membrane/Display Panel
MRP200xkypd.wmf/mrp-200xckypd.wmf
PDRP-2001 Keypad PDRP-2001C Keypad

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 17
Components Product Description
• Supervisory - yellow indicator
• AC Power - green indicator
• System Trouble - yellow indicator
• Alarm Silenced - yellow indicator
• Pre-Discharge - red indicator
• Discharge - red indicator
• Abort - yellow indicator
Local Piezo Sounder
A piezo sounder provides separate and distinct sounds for alarm, trouble, maintenance and
supervisory conditions as follows:
• Alarm - on steady
• Trouble - pulse 1 second on and 1 second off
• Maintenance - pulse ½ second on and ½ second off
• Supervisory - pulse ½ second on and ½ second off
1.4 Components
Main Circuit Board
The main circuit board contains the system’s CPU and other primary components and wiring
interface connectors. Optional modules plug in and are mounted to the main circuit board.
Power Supply
One FLPS-7 power supply is provided standard with each FACP, mounted to a chassis.
Cabinet
The backbox measures 16.65” (42.29 cm) x 19.0” (48.26 cm) x 5.207” (13.23 cm) and provides
space for two batteries (up to 18 Amp Hours). Also available are the optional dress panel
(DP-51050 [red] and trim-ring TR-CE [red]. The Canadian version is supplied standard with a
modified dress panel and one ANN-LED annunciator module.
Batteries
The cabinet provides space for two 18 Amp Hour batteries (larger batteries require use of a UL
listed battery box such as the BB-55F or BB-26). Batteries must be ordered separately.
1.5 Optional Modules and Accessories
CAC-5X Class A Converter Module
The CAC-5X Module can be used to convert the Style B (Class B) Initiating Device Circuits to
Style D (Class A) and Style Y (Class B) Output Circuits to Style Z (Class A). The modules connect
to J2 and J7 on the FACP main circuit board. Note that two Class A Converter modules are required
to convert all six Initiating Device Circuits and four Output Circuits.
4XTMF Transmitter Module
The 4XTMF provides a supervised output for local energy municipal box transmitter and alarm and
trouble reverse polarity. It includes a disable switch and disable trouble LED. A module jumper
option allows the reverse polarity circuit to open with a system trouble condition if no alarm
condition exists. he 4XTMF mounts to the main circuit board connectors J4 & J5.
ANN-SEC Secondary ANN-BUS Module
The ANN-SEC module provides another ANN-BUS port for more wiring flexibility and for
Canadian applications requiring remote annunciation.

18 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Product Description Optional Modules and Accessories
ANN-80 LCD Annunciator
The ANN-80 (red) and ANN-80-W (white) are remote LCD annunciators that mimic the
information displayed on the FACP LCD display.
ANN-80C LCD Indicator (Canadian applications)
The ANN-80C is a remote LCD indicator which mimics the information displayed on the FACP
LCD display but does not allow remote control of the FACP.
The ANN-80C is not ULC-S527 3rd Edition Listed.
ANN-LED Annunciator Module
The ANN-LED Annunciator Module provides three LEDs for each zone: Alarm, Trouble and
Supervisory.
ANN-RLY Relay Module
The ANN-RLY Module, which can be mounted inside the cabinet, provides 10 Form-C relays.
Dress Panel
A dress panel DP-51050 (red) is available as an option. The dress panel restricts access to the
system wiring while allowing access to the membrane switch panel. The Canadian version is
supplied standard with a modified dress panel.
TR-CE Trim-ring
A trim-ring TR-CE (red) is available as an option. The trim-ring allows semi-flush mounting of the
cabinet.
Battery Box
The BB-55F or BB-26 battery box may be used to house two batteries greater than 18 Amp Hour.
The battery box mounts directly below the control panel cabinet, centered to the main circuit board.
Battery Chargers
CHG-75 Battery Charger
The CHG-75 is capable of charging up to 75 AH lead-acid batteries with the FACP. The FACP
battery charger must be disabled, through software programming, when using the CHG-75. The
charger and up to 26 AH batteries can be housed in the BB-26 battery box. Larger batteries and the
charger can be housed in the BB-55F battery box which can be mounted up to 20 feet away from
the control panel. Refer to the CHG-75 Manual for additional information.
CHG-120F Battery Charger
The CHG-120F is capable of charging up to 120 AH lead-acid batteries with the FACP. The FACP
battery charger must be disabled, through software programming, when using the CHG-120F. The
batteries and charger can be housed in the BB-55F battery box which can be mounted up to 20 feet
away from the control panel. Note that when using the BB-55F for housing the charger and
batteries greater than 26AH, multiple BB-55Fs are required. Refer to the CHG-120F Manual for
additional information.

PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016 19
Section 2: Installation
The cabinet can be surface mounted or semi-flush mounted. The door is removable during the
installation period by opening and lifting it off the hinges. The cabinet mounts using two key slots
at the top of the backbox and two additional securing holes located at the bottom.
Carefully unpack the system and check for shipping damage. Mount the cabinet in a clean, dry,
vibration-free area where extreme temperatures or levels of humidity are not encountered. The area
should be readily accessible with sufficient room to easily install and maintain the panel. Locate
the top of the cabinet approximately 5 feet (1.5 m) above the floor with the hinge mounting on the
left. Determine the number of conductors required for the devices to be installed. Sufficient
knockouts are provided for wiring convenience. Select the appropriate knockout(s) and pull the
conductors into the box. All wiring should be in accordance with the National and/or Local codes
for fire alarm systems.
2.1 Backbox Mounting
To prevent damage to the circuit board and to facilitate backbox mounting, the chassis with main
circuit board and power supply can be easily removed. Loosen the two 3/8” nuts securing the top
flanges of the chassis, then slide the chassis up to free it from the lower tabs. Place the chassis
assembly in a protective antistatic bag in a safe location until it can be reinstalled in the backbox.
Mark and predrill hole in the wall for the center top keyhole mounting bolt using the
dimensions illustrated in Figure 2.2 on page 21
Install center top fastener in the wall with the screw head protruding
Place backbox over the top screw, level and secure
Mark and drill the left and right upper and lower mounting holes
Note: outer holes (closest to sidewall) are used for 16” on-center stud mounting
Install remaining fasteners and tighten
!
CAUTION: STATIC SENSITIVE COMPONENTS
THE CIRCUIT BOARD CONTAINS STATIC-SENSITIVE COMPONENTS. ALWAYS GROUND
YOURSELF WITH A PROPER WRIST STRAP BEFORE HANDLING ANY BOARDS SO THAT
STATIC CHARGES ARE REMOVED FROM THE BODY. USE STATIC SUPPRESSIVE
PACKAGING TO PROTECT ELECTRONIC ASSEMBLIES.

20 PDRP-2001 Series Manual — P/N 53043:E4 7/28/2016
Installation Backbox Mounting
T
B
6
S
W
1
mounting studs
mounting slots
mounting tabs
mounting holes
grounding stud:
attach solid earth
ground wire (refer to
Figure 2.4 on page 23)
Board on Chassis
Backbox
Figure 2.1 Chassis Mounting in Backbox
rp2001brdinbox.wmf
mounting slots
This manual suits for next models
2
Table of contents
Other System Sensor Control Panel manuals
Popular Control Panel manuals by other brands

Ferroli
Ferroli 0Q2K10XA Installation and assembly instructions

Miranda
Miranda iMC-Panel-200 user guide

PLDT Home
PLDT Home TELPAD MT7 quick guide

weintek
weintek MT600iWP Series Installation instruction

Emerson
Emerson Fisher LCP100 instruction manual

STG-BEIKIRCH
STG-BEIKIRCH TRZ Basic 2A/UP Technical information and operating instruction

AKO
AKO PROCool AKO-17632 quick guide

ICP DAS USA
ICP DAS USA TPD-430 quick start guide

Chamberlain
Chamberlain LiftMaster 398LM Owner's instructions

DMP Electronics
DMP Electronics XT Series Programming guide

Teletask
Teletask AURUS-OLED user manual

Nordelettronica
Nordelettronica KIT-NE185-12S instruction manual