TÄNDA REGENERATE User manual

TÄNDA REGENERATETM
ANTI-AGING
ANTI-ÂGE
REJUVENECEDORA
LIGHT THERAPY TREATMENT
TRAITEMENT DE PHOTOTHÉRAPIE
TRATAMIENTO DE FOTOTERAPIA
USER MANUAL
MODE D’EMPLOI
MANUAL DEL USUARIO


FIG. I
1
6
5
2
3
4

FIG. II

CONTENTS
Introduction to Tända RegenerateTM.............................1
Indications for Use......................................................1
Package Contents .......................................................1
Getting Started ................................................................2
Device Set Up..............................................................2
Charging the Battery ..................................................3
Using the Tända Regenerate Anti-Aging
Light Therapy Treatment........................................3-4
Using the Goggles ......................................................4
Indicators & Sensors ..................................................5-6
Tips & Troubleshooting..................................................6
Tända Travel Tips....................................................6-7
Troubleshooting.......................................................7-8
Maintenance.....................................................................9
Cleaning........................................................................9
Disposal........................................................................9
Replacing your Tända Light
Therapy Treatment Head.......................................... 9
Tända Customer Service............................................. 10
Return Policy............................................................. 10
Warranty ..............................................................11-12
Contraindications, Warnings and Precautions......... 13
Contraindications ..................................................... 13
Warnings.................................................................... 14
Precautions................................................................ 15
Specifications..........................................................16-17

1
INTRODUCTION TO TÄNDA REGENERATE
Congratulations on your purchase of the Tända
Regenerate Anti-Aging Light Therapy Treatment.
From the number one manufacturer of home-use light
therapy products, the Tända Regenerate Anti-Aging
Light Therapy Treatment delivers professional
treatments in the comfort of your own home in just
minutes a day. Tända Regenerate uses red LED light
to diminish the appearance of fine lines and wrinkles
and improve skin color, texture, firmess and hydration.
INDICATIONS FOR USE
Tända Regenerate Anti-Aging Light Therapy
Treatment is for cosmetic use only.
PACKAGE CONTENTS:
• Tända Regenerate Anti-Aging Light Therapy
Treatment Head (1)
• Tända cordless handpiece (2)
• Recharging stand (3)
• Tända Regenerate Pre-Treatment Gel
• Power supply
• Goggles

2
COMPONENTS:
• Plastic plug (to hold charge) (4)
• Orange power button (5)
• Indicator light (6)
GETTING STARTED
DEVICE SET UP
Getting started with the Tända light therapy device
is easy.
1. Unpack the Tända light therapy device and all the
accessories.
2. Before use, remove the plastic plug (4) from the
bottom of the Tända cordless handpiece,
otherwise it will not activate when the orange
power button (5) is pressed.
3. Peel the protective lens cover off the treatment
head and discard.
4. Firmly place device in the recharging stand and
use the power supply to plug the recharging
stand into a power outlet. Ensure orange indicator
light (6) is on. Once the charging is complete
(requires about 4 hours), the orange light will
turn off. See Charging the Battery for details.
5. The Tända light therapy device is now ready to
begin treatment.

3
CHARGING THE BATTERY
• Firmly place the device in the recharging stand (3)
• Plug the power supply into the base of the
recharging stand and the other end into an AC
power outlet (such as a wall socket).
• The power supply may also be plugged directly
into the receptacle at the bottom of the handpiece
(2) and then into an AC power outlet.
• The device will take about 4 hours to charge.
• The indicator light (6) will be orange while device
is charging; it will turn off when charging is complete.
• The Tända device is now ready to be used unplugged.
• Keep the Tända device fully charged at all times.
It is recommended to store the device in the
recharging stand after every use. You cannot
overcharge your Tända light therapy device.
• A fully charged device will be able to deliver 10,
three-minute cycles between charges.
Note:
• You can also use your device plugged into an
AC power outlet (such as a wall socket). Simply
plug one end of the power supply into the
receptacle at the bottom of the handpiece and
connect the other end to the AC outlet in the wall.
The device will draw power from the AC outlet.
USING THE TÄNDA REGENERATE
ANTI-AGING LIGHT THERAPY TREATMENT
1. Cleanse your skin.
2. Apply the Tända Regenerate Pre-Treatment Gel
all over your face (avoid eyes).

4
3. Press the orange power button (5) once.
4. When the indicator light (6) is flashing green,
the device is ready to begin a treatment.
5. Place the Tända Regenerate device in contact
with your skin (the light will only activate when
the treatment head is in direct contact with the skin).
6. The light treatment head operates in three
minute cycles. An audible beep will sound every
30 seconds. Two quick beeps will indicate when
the cycle is complete.
7. Treat for three minutes over each target area
(e.g. around the eyes). Then move the device all
over your face, moving every 30 seconds with
the “beep” until you have treated all areas.
8. Allow 24 hours between treatments.
9. Use every day for 30 days, then three times per
week to maintain results.
10. Store the device in its recharging stand.
USING THE GOGGLES
The goggles have been provided for your conve-
nience and comfort as some people find the light
bright. Company sponsored testing showed that,
when used as directed, the device did not pose risk
of damage to the eyes.
• Position the goggles over your eyes
• Tie the elastic band so that the goggles fit
comfortably around your head.
Note: Do not shine light source directly into the eyes.

5
INDICATORS & SENSORS
The Tända device has light and sound indicators to
identify treatment cycles and performance behavior.
LIGHT INDICATORS
Flashing Green
Steady Orange
Steady Red
Off
Tända device is ready
or delivering a treatment
The battery is being charged
An error has occurred. It may be:
• A problem with the installation
of the treatment head
• The battery is low on power
• The unit may be overheating
The Tända device is off
SOUND INDICATORS
One Beep
One quick
beep every
30 seconds
Two Beeps
Start of treatment
A treatment is underway and it has
been 30 seconds since the last beep
or the beginning of the treatment
End of treatment cycle.
— Or —
Low battery

6
SENSORS
An internal Temperature Sensor will turn the device
off if the treatment head surface gets too warm. Allow
the device to cool for 5-10 minutes before restarting.
The Contact Sensor ensures that the device will only
activate when in contact with skin. The device will turn
off automatically if it is not applied to the skin within
20 seconds or if removed from the skin for more than
20 seconds.
TIPS & TROUBLESHOOTING
TÄNDA TRAVEL TIPS
The Tända light therapy device’s light weight design
and compact form makes it an easy travel companion.
Overnight Travel
If you will be away for a day or two, and you don’t
want to miss a treatment, you can travel with your
device without having to recharge it while away from
home. Simply remove the fully charged device from
the recharging stand and insert the plastic plug (4)
in the bottom of the device. The plastic plug will
prevent the device from discharging. A fully charged
device will be able to deliver 10, three-minute cycles
between charges.
Three Beeps
Four Beeps
High temperature on treatment
head surface
Treatment head has been
disconnected

7
Universal Voltage
The Tända device is designed to charge safely with
either 110/120V or 220/240V systems. It can be
charged in foreign countries using an electric adaptor
plug.
International Plugs
The Tända power supply comes with an interchange-
able plug feature. Additional plugs are available
for different international locations. Contact Tända
Customer Service if you wish to purchase the Tända
International Power Adaptor Kit.
TROUBLESHOOTING
In the event that the Tända light therapy device fails
to perform as intended, the following notes will help
to identify potential problems with the device and its
setup.
Light indicator
is off while the
power adaptor
is plugged into
a working AC
outlet
Device turns off
after 3 minutes
Battery pack is fully charged
(device is ready to use).
— Or —
Battery isn’t charging properly
(Ensure the device is secure
in the recharging stand).
This indicates the end of a
treatment cycle. Press
the orange button to start
another treatment cycle.
If Do This

8
If you still have questions please visit
tandaskincare.com for more tips and troubleshooting.
Device will not
start when the
orange power
button is
pressed.
Indicator light
is flashing
green but treat-
ment head
is not illuminated.
The indicator
light isn’t
orange when
device is
charging.
Device shuts off
in mid-treatment
or after only a
few treatments.
Ensure the white plug is not in the
bottom of device.
— Or —
Charge the device (Indicator light
will be orange when charging
properly).
— Or —
Check to see that the treatment
head is secure.
Ensure that the light surface is
touching the skin.
Ensure that the handpiece is
firmly in the recharging stand
and the stand is plugged into a
working AC outlet.
Take treatment head off and let
the device cool for 5-10 minutes.
— Or —
Ensure you are charging your
Tända device correctly, see
Charging The Battery.

9
MAINTENANCE
CLEANING
Use a damp, soft, lint-free cloth and a mild alcohol-
free detergent to clean the Tända treatment head
surface.
Note: Do not immerse device in water at any time.
DISPOSAL
Waste Electrical and Electronic Equipment
(WEEE)
For information and instructions regarding the
proper disposal of this product in your location please
visit tandaskincare.com
REPLACING YOUR TÄNDA LIGHT THERAPY
TREATMENT HEAD: (FIG. II)
Tända Light Therapy Treatment Heads are designed
to last for up to 300 hours, at such time the treatment
head will no longer emit light. Replacement treatment
heads are available through Tända Customer Service.

10
TÄNDA CUSTOMER SERVICE
Additional information about your Tända light therapy
device is available at tandaskincare.com, your place
of purchase or from Tända Customer Service.
Customer Service Contact:
Pharos Life Corporation
11-380 Jamieson Parkway
Cambridge ON, N3C 4N4
Toll free (NA) 1.877.651.1177 x 233
Hours of operation: Mon-Fri, 9am-5pm EST
RETURN POLICY
All returns are subject to the return policy at point of
purchase. Pharos Life Corporation does not accept
returns for convenience.

11
WARRANTY
Register your Tända light therapy device warranty
at tandaskincare.com
Your Tända product is warranted to be free from
defect in material and workmanship for a period
of one year after its original purchase date under
normal use. This warranty extends only to the original
retail purchaser with original proof of purchase and
only when purchased from an authorized Tända
retailer or reseller.
If the product should become defective within the
warranty period, contact Pharos Life Corporation.
In North America, call our customer service
team at 519.651.1177x233 or toll free at
1.877.651.1177x233 for replacement. If you
are outside of North America, contact your local
distributor. Contact information can be found at
tandaskincare.com. Pharos Life Corporation reserves
the right to replace a defective product with the most
comparable product currently available. Your exclusive
remedy for any defective product covered by this
limited warranty is limited to the replacement of the
defective product. Pharos Life’s entire liability for
any defective product shall in no event exceed the
purchase price for the defective product.

12
This warranty does not cover products determined
by Pharos Life Corporation to be damaged by any of
the following:
• Accident, misuse, abuse or alteration
• Servicing by unauthorized persons
• Use with unauthorized accessories or use other
than as instructed
• Connecting to incorrect current and voltage
• Any other conditions beyond our control
TO THE EXTENT PERMITTED BY LAW, PHAROS LIFE
CORPORATION SHALL NOT BE RESPONSIBLE FOR
ANY DIRECT OR INDIRECT DAMAGES RESULTING
FROM THE USE OR MISUSE OF THIS PRODUCT
INCLUDING ANY GENERAL, INCIDENTAL, SPECIAL,
OR CONSEQUENTIAL DAMAGES. ALL IMPLIED
REPRESENTATIONS, WARRANTIES OR CONDITIONS
INCLUDING BUT NOT LIMITED TO ANY IMPLIED
REPRESENTATIONS, WARRANTIES OR CONDITIONS
OF FITNESS AND MERCHANTABILITY ARE LIMITED
IN DURATION TO ONE YEAR FROM DATE OF ORIGINAL
PURCHASE.
This warranty gives you specific legal rights, and
you may also have other rights that vary depending
on your state, province or other jurisdiction. Some
jurisdictions do not allow the exclusion or limitation
of incidental or consequential damages, or limitations
on how long an implied warranty lasts, so the above
limitations and exclusions may not apply to you.

13
CONTRAINDICATIONS, wARNINGS
AND PRECAUTIONS
CONTRAINDICATIONS
• CAUTION! Do not use over any suspicious
or cancerous lesion. The effect of this device
on suspicious or cancerous lesions is unknown.
• CAUTION! Do not use if you are sensitive to light.
Doing so may result in a photosensitive reaction.
• CAUTION! Do not use if you are taking drugs
known to make you sensitive to light. Common
examples of drugs that may make you sensitive
to light include: Antihistamines used in cold and
allergy medicines; Non-steroidal Anti-inflammatory
Drugs (NSAIDs), used to control pain and
inflammation; and Antibiotics, including tetracy-
clines and the sulfonamides, or “Sulfa” Drugs.
• CAUTION! Do not use with Liniments, salves
or ointments that contain heat-producing
ingredients, as skin burn could result.
• CAUTION! Do not use over a pregnant uterus.
Doing so may be harmful to the fetus or patient.
• CAUTION! Do not use over or near a recent steroid
injection. Doing so may result in a photosensitive
reaction.
• CAUTION! Do not use on infants. Doing so may
result in an injury.
• CAUTION! Do not use over the thyroid gland
(neck area). Doing so may stimulate the gland.

14
WARNINGS
To reduce the risk of electrical shock that may cause
injury or death:
1. Always attach the AC power adapter to the device
first, then into the outlet.
2. Do not place or store the device where it can fall
or be pulled into a tub or sink. Do not place
or drop into water or other liquid.
3. Keep all electrical appliances away from water.
If the unit accidentally falls into water, carefully
unplug the unit.
4. Never drop or insert any object into any openings
on the device.
5. Only use the power adapter provided with this
device.
6. Never operate this device if it has a damaged
cord or plug, if it is not working properly, if it has
been dropped or damaged, or submerged
in water. Return the device to Pharos Life for
examination and repair.
7. Do not disassemble the device as this may cause
unit damage, malfunction, electrical shock, fire
or personal injury. There are no user-serviceable
parts inside the unit.
8. Do not allow children to use the device unsupervised.
WARNING: To prevent fire or possible burns:
1. Keep away from flammable aerosol products
being used or where oxygen is being administered.
2. Turn off the device if it becomes unusually warm
to touch.

15
WARNING: Stop immediately, if you experience any
adverse effects or develop prolonged redness.
You may be experiencing a photosensitive reaction.
PRECAUTIONS
• Read all instructions before using your Tända
light therapy device.
• The Tända device should be operated, transported
and stored in the manner specified in this manual.
(see section SPECIFICATIONS)
• The device should be routinely checked before
each use to determine the device functions properly.
• Failure to use and maintain the Tända device
in accordance with the instructions outlined
in this manual will invalidate the warranty.
• Do not scratch, mark or otherwise damage the
light emitting surface.
• Do not operate this device in an environment
where other devices, which intentionally radiate
electromagnetic energy in an unshielded manner,
are being used. Portable or mobile radio frequency
communication equipment can affect medical
electrical equipment.
Table of contents
Languages: