Tünkers 8-Channel Motor Terminal
for controlling maximum 8 electronic clamping devices
Subject to technical alterations Page -10- 06/03/2018
TÜNKERS®Maschinenbau GmbH Am Rosenkothen 8 • D-40880 Ratingen Tel. 02102 4517-0 • Fax 02102 445808 Internet www.tuenkers.de
6. Electrical characteristics
Input / output control voltage Ust at XS1/XS2:
Voltage SELV or PELV in accordance with EN 61010-2-201
Uin +24V +/- 10% Residual ripple 1.2 V
No-load:
Iin 0.05Atyp 0.075Amax no connection
Initiators / motors /
general inputs
Iin 0.035Atyp 0.05Amax per line pair initiator / motor
Iin 0.05Atyp 0.1Amax per general input
(depending on the initiator)
Iinno-load 0.25Atype 0.575Amax No-load with 6 connected
initiators and clamps and
4 general inputs.
Full load:
Iin 0,5 Atype 1,2 Amax
Input load voltage Ul at XS3:
Uin +24V +/- 10% Residual ripple 1.2 V
Iinno-load 0,1Atype 0,15Amax no control of the
clamping motors
55Apeak/5ms Inrush peak current
(Load int. capacitors)
50Apeak/5ms Switch on after 5 sec
Power failure
40Apeak/5ms Switch on after 4 sec
Power failure
30Apeak/5ms Switch on after 5 sec
Power failure
20Apeak/5ms Switch on after 2 sec
Power failure
10Apeak/5ms Switch on after 1 sec
Power failure
Iin 4ATime with the active command execution per
clamping drive (EK63)
25Apeak Inrush current of the clamp motor (EK63)
With control of 6 clamps at the same time:
24ATime / 35Apeak (specification for power supply)
Insulation between control voltage Ust and load voltage UI
Insulation voltage min 3750V (rpm)
UL certification in accordance with UL1577
VDE certification in accordance with VDE V 0884-5/-10 or EN60747-5-
2/-5
Motor signals to XA1 –XA8
Iout 4A for a max. movement time of 5s
25Apeak 5ms/50ms (ta/tf)
Internal temperature and short-circuit monitoring of the motor driver
Connection initiators for end position detection XE1 –XE8
(Plus switching)
Uout +/-24V +/- 10% Residual ripple 1.2 V
Iout 50mATime 100mApeak
Iin 5mA +/- 10% Plus pole switched
Connection general inputs XE9 –XE12 (Plus switching)
Uout +/-24V +/- 10% Residual ripple 1.2 V
Iout 100mATime 150mApeak
Iin 5mA +/- 10% Plus pole switched
Interface PROFINET-IO XBA and XBE (TMI-8 PN)
Baud rate: 100 MBaud
Ethernet protocol UDP/IP, TCP/IP
Interface Ethernet-IP XBA and XBE (TMI-8 EIP)
Baud rate 10 and 100MBit/s autodetect
Ethernet IP/Address Assignment via DHCP server
Ethernet protocol UDP/IP or TCP/IP
Integrated web server- there is one HTML screen on which the system
parameters of the Ethernet IP module are represented. The web screen
can be edited or replaced by a customer-specific web screen.
Integrated FTP server that permits access to the data system of the
device via the field bus. Access is protected by user names and pass-
word.
Interface DeviceNet XBA and XBE (TMI-8 DN)
Data rate 125KBit (default setting), 250kBit, 500KBit
Data format Group 2 Slave
Vendor ID 272
Device type 12 (communication adapter)
Interface Profibus XBA and XBE (TMI-8 PB)
Data rate 500KBit (default setting), 1.5 MBit
Diagnosis data: max. 8 Byte
Sync: supported
Freeze: supported
ID-No.: 0x2079 or 0x3218