TAGHeuer Timin Page6/8
3. Select the correct COM Port
4. Browse and select the correct file (Rx/Tx)
5. Push START on the screen
6. Turn on the HL 675 (hold down for 5 seconds « ON »
The HL 675 will enter in a special setup mode
7. Until the file downloaded then, validate with « OK »
Hands on: Reinitialize your devices
If the systems are in a unknown mode, you can Initialise your system in the OEM
configuration (Channel 1, Team A, Buzzer On, Baud Speed 9600bps, Mode Impulse).
Push simultaneously SET and TEST BATT for 3 seconds.
All LED’s will flash and the system will beep until it is reinitialized.
4. Technical Specification
GeneraloImpulse response precision: +/- 1/10'000 sec
oTransmitting delay: 200ms
oFrequency : 869 MHz REC 70-03
oPower 500 mW
oAutonomy (at +68°F / 20°C) 24 hours (1 Impulse per min.)
8 hours (THbC data transm.)
1 data string each 4 sec.
oImpedance : 50 Ohms
oAntenna 1/4 Wavelength 2.5dBi
oImpulse Input Short-Circuit / Working contact
Respect the polarity
oImpulse Output 4 separated outputs
Isolated by an opto-coupler
Manages up to 4 simultaneous inputs
oChannel : 4 different channels (1,2,3,4)
oTEAM function : 4 different codings (A,B,C,D)
oNormal use temperature between - 4°F (-20°C) and +131°F (+55°C)
oCharging temperature between +32°F (0°C) and +86°F (+30°C)
oSize (without antenna) 152 x 108 x 34 mm
oWeight : 470g / radio
oPower supply : 12 V DC / 800 mA min
Lithium-Polymer Battery
oType 12V Li-Pol 2000mAh
oCharging current 800mA minimum (~ 5 hours)
Charger HL540-10
oPrimary 230V - 50Hz - 125mA
oSecondary 12V – 1250 mA
Warranty : One year after delivery of your purchase
The warranty is null and void under the following conditions:
-if the battery is out of order