manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TAMURA
  6. •
  7. Other
  8. •
  9. TAMURA TMRF-1-U001-KM User manual

TAMURA TMRF-1-U001-KM User manual

Popular Other manuals by other brands

Opticon EduMic Compatibility guide

Opticon

Opticon EduMic Compatibility guide

Kessil A360W owner's manual

Kessil

Kessil A360W owner's manual

TEFAL ULTRA COMPACT MIXER manual

TEFAL

TEFAL ULTRA COMPACT MIXER manual

Martin Audio WS18X - SCHEMATICS manual

Martin Audio

Martin Audio WS18X - SCHEMATICS manual

Hendrickson AR2 series Service instructions

Hendrickson

Hendrickson AR2 series Service instructions

GO Industries 38017 installation instructions

GO Industries

GO Industries 38017 installation instructions

Cissell 30LBCMAN2 manual

Cissell

Cissell 30LBCMAN2 manual

RIDGID K-60SP manual

RIDGID

RIDGID K-60SP manual

Gage Bilt GB751SH-5 Original instructions

Gage Bilt

Gage Bilt GB751SH-5 Original instructions

OVE SIERRA 60 installation manual

OVE

OVE SIERRA 60 installation manual

ReelCraft 7800 OLB21 operating instructions

ReelCraft

ReelCraft 7800 OLB21 operating instructions

Body Armor 4x4 ECO-SERIES user manual

Body Armor 4x4

Body Armor 4x4 ECO-SERIES user manual

ROBLIN DROP Dimensions

ROBLIN

ROBLIN DROP Dimensions

EMG EMG-ACB BARREL Installation information

EMG

EMG EMG-ACB BARREL Installation information

MiniSolar MT-150 Assembling Guide

MiniSolar

MiniSolar MT-150 Assembling Guide

Parkside PSZ 250 B2 Operation and safety notes

Parkside

Parkside PSZ 250 B2 Operation and safety notes

ABB REM 610 Technical reference manual

ABB

ABB REM 610 Technical reference manual

Tyent ACE-13 user manual

Tyent

Tyent ACE-13 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2D-53-00001000
TAMURA CORPORATION
-1
/
16 -
TMRF-1-U001-KM
User’s Manual
TAMURA CORPORATION
2D-53-00001000
TAMURA CORPORATION
-2
/
16 -
1.Scope
This document is the user’s manual of Radio Frequency Identification [RFID] Reader
/Writer with Universal Serial Bus [USB] for Konica Minolta Business Technologies, Inc.
2.Product Name
TMRF-1-U001-KM (Product reference code in TAMURA corporation:N-22200066-00)
3.Outlines of product
・This product is a compact RFID reader / writer with USB interface.
・This product can read and write data for RFID tag by 13.56MHz radio frequency with RFID
wireless interface.
・The USB interface is capable of communicating by low speed [1.5Mbps].
2D-53-00001000
TAMURA CORPORATION
-3
/
16 -
4.Safety Information
Read the following safety information and handling information before using TMRF-1-U001
-KM to avoid injury.
4-1.Important safety information
Failure to follow these safety instructions could result in fire, electric shock, or
other injury or damage.
○DO NOT use this product in hospitals and health care facilities, especially near of sensitive
equipments such as heart pacer to external radio frequency emissions.
○This product assumes the activity to a general electronic instrument.(AV equipments, OA
equipments, amusement equipments, etc.)
A very advanced reliability is required and the activity to the equipment and units (medical
equipment, an aerospace plane machine, a nuclear equipment, various safety devices, etc.)
with which a trouble and malfunction of a product are directly concerned with a human
life cannot be performed.
Failure to follow these handling instructions could result in damage to
TMRF-1-U001-KM or other property.
○Since this product consists of precision electronic parts, please do not give a strong
impact.
If an impact is given to a product or it is made to fall, it will become a cause of a
crash or a trouble.
○DO NOT put into a micro wave oven or a high-pressure container.
It becomes a cause of a trouble.
○DO NOT use TMRF-1-U001-KM in rain or any wet location.
○Please do not install in an unstable location.
If it is installed in a shaky stand top, a leaning place, etc., it will fall and will become a
cause of a crash or an injury.
○Please do not pull a moving part and an attachment (especially connector) strongly,
or do not bend them.
They become a cause of a crash or a trouble.
○Keep this product out of the direct rays of the sun.
It becomes a cause of a trouble.
○DO NOT use window cleaners, aerosol sprays, solvents, alcohol or abrasion to clean.
○This product is CMOS product.
Please do not keep it in the place easily charged with electricity.
It becomes a cause of a trouble.
○When you discard this product, please process as an industrial waste.
Warning
Caution
2D-53-00001000
TAMURA CORPORATION
-4
/
16 -
4-2 .Operating condition
TAMURA Corporation will grant a nonexclusive license of this product to user on
condition of the following.
○DO NOT perform program analysis, reverse engineering, copy, change, re-distribution, etc.
○This product is a product approved by Wireless Telegraph Law of each country.
You will be punished by violation of Wireless Telegraph Law if a transmitting output is raised
by use of an external antenna, or reconstruction.
○The specification of this product and the contents of related data may be changed without
a preliminary.
○This product is based on regulation of the following countries.
Japan , the United States of America , Canada, Australia and New Zealand
When it is in used except the countries which indicated, TAMURA Corporation cannot take
responsibility.
○This equipment complies with FCC/IC radiation exposure limits set forth for uncontrolled
equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement
C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules.
This equipment has very low levels of RF energy that it deemed to comply without maximum
permissive exposure evaluation (MPE). But it is desirable that it should be installed and
operated with at least 20cm and more between the radiator and person’s body (excluding
extremities :hands, wrists, feet and ankles).
○Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment
○This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
○This device complies with Part 15 of FCC Rules and RSS-Gen of IC Rules.
Operation is subject to the following two conditions : (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of this device.
2D-53-00001000
TAMURA CORPORATION
-5
/
16 -
4-3. Notes of use
○DO NOT move adjustment parts of this product.
○When a metal thing is near this product or this product is covered by a metal thing,
the characteristic may deteriorate remarkably.
○DO NOT insert a USB connector by force (even if it does not put in strong power,
it can insert smoothly).
It is NOT connectable unless it inserts at the right direction and the right angle.
When you cannot insert, please check direction of a connector once again, without
inserting by force.
○DO NOT use it in the environment where this product dews.
5.Product structure
RFID R/W with USB [TMRF-1-U001-KM]
①USB connector
②RF CAP (The jack for external antennas)※Prohibition of use
③The hole for a strap
④USB CAP
④
①②
③
2D-53-00001000
TAMURA CORPORATION
-6
/
16 -
6.USB Control commands
6-1.USB communications protocol (host -> RFID R/W -> tag)
Calling
device request
bmRequestType = 0x43,0xC3
bRequest =100+No.
(The following table)
wValue =notused
wIndex =notused
wLength =bytecount
data = parameter data
1~3 4 ~ n n+1 n+3
command parameter CRC16 EOT
The following table The following table 2bytes 0x04
CRC16 calculation value
parameter=From command to EOT considers it as 1 text.
No command function parameter1 parameter2 parameter3
00 “U00” ROM Version Read XX,XX YMD Nothing ○
01 “U01” Inventory Nothing ○
02 “U02” Stay Quiet UID(8) ○
03 “U03” N Block Read(All data)
(Max=9Blocks)
UID(8)
S
Block#(1) Block count(1) ○
04 “U04” N Block Write(All data) ×
05 “U05” Read Single Block UID(8)*1 Block#(1) ○
06 “U06” Write Single Block UID(8)*1 Block#(1) data(4) ○
07 “U07” Lock Block UID(8)*1 Block#(1) ○
08 “U08” Read Multi Blocks
(Max=9Blocks)
UID(8)*1
S
Block#(1) Block count(1) ○
09 “U09” Write Multi Blocks ×
10 “U10” Select Tag UID(8) ○
11 “U11” Reset to Ready UID(8)*1 ○
12 “U12” Write AFI UID(8)*1 AFI(1) ○
13 “U13” Lock AFI UID(8)*1 ○
14 “U14” Write DSFID UID(8)*1 DSFID(1) ○
15 “U15” Lock DSFID UID(8)*1 ○
16 “U16” Get System Information UID(8)*1 ○
17 “U17” Get Multi Block Security Status UID(8)*1
S
data(1),
data count(1)
○
18 “U18” Write 2 Blocks
UID(8)*1 Block#(1),
2(1)
data1(4),
data2(4)
○
19 “U19” Lock 2 Blocks UID(8)*1 Block#1(1) ○
20 “U20” ×
21 “U21”
Special process1(Buzzer etc)command data ○
22 “U22” ×
notes:
S
=start、Block#=01〜64
Blockcount:Serial line max = 9 /USB max=9
“U03” is the same as “U08”
Special process1(command):0x80= Buzzer function(ON),0x40= Buzzer function(OFF),0x01= Buzzer(ON)
"U18 [Write 2 Blocks]" and "U19 [Lock 2 Blocks]" are Tag-it. It is original command.
Configuration of UID : There are 2 ways that all 8 bytes are assigned and an implementation-supplier code
is assigned.
(*1) E0 MM XX XX XX XX XX XX -> 00 MM XX XX XX XX XX XX
[MM : an implementation-supplier code assigned = 04(Philips),05(My-D),07(TI)]
2D-53-00001000
TAMURA CORPORATION
-7
/
16 -
No command function parameter1 parameter2 parameter3
23 “U23”
24 “U24”
25 “U25”
26 “U26”
27 “U27”
28 “U28”
29 “U29”
30
31 “U31”* Inventory Nothing ○
32 “U32”* Stay Quiet UID(8) ○
33 “U33”* N Block Read(All data)
(Max=9Blocks)
UID(8)*1
S
Block#(1),
Block count(1)
○
34
35 “U35”* Read Single Block UID(8)*1 Block#(1) ○
36 “U36”* Write Single Block UID(8)*1 Block#(1) data(4) ○
37 “U37”* Lock Block UID(8)*1 Block#(1) ○
38 “U38”* Read Multi Blocks UID(8)*1
S
Block#(1) Block count(1) ○
39
40 “U40”* Select Tag UID(8) ○
41 “U41”* Reset to Ready UID(8)*1 ○
42 “U42”* Write AFI UID(8)*1 AFI(1) ×
43 “U43”* Lock AFI UID(8)*1 ×
44 “U44”* Write DSFID UID(8)*1 DSFID(1) ×
45 “U45”* Lock DSFID UID(8)*1 ×
46 “U46”* Get System Information UID(8)*1 ×
47 “U47”* Get Multi Block Security Status UID(8)*1
S
data(1),
data count(1)
×
48 “U48”*
49 “U49”*
50
51
52
●* is command of a My-D card.
●My-D assumes 124Page (248Block) with the architecture of 4 bytes/Block now.
●Since the write-in result of My-D has returned transmission data as it is, read is required for it again.
2D-53-00001000
TAMURA CORPORATION
-8
/
16 -
6-2. USB communications protocol (tag -> RFID R/W -> host)
1 2~4 5~n n+1 n+3
ENQ command parameter CRC16 EOT
0x05 The following table The following table 2bytes 0x04
CRC16 calculation Value
From ENQ to EOT considers it as 1 text
CRC16 : JIS X 6323-3(Part III: Refer to Collision Prevention and Transmission Protocol) ISO/IEC 13239
No command function parameter1 parameter2 parameter3
00 “R00” ROM Version XX,XX YMD Version(2) YY(1),MM(1) DD(1) ○
01 “R01” Inventory DSFID(1) UID(8) ○
02 “R02” Stay Quiet UID(8) ○
03 “R03” N Block Read(All data)
(Max=9Blocks)
UID(8)*1
S
Block#(1),
Block count(1)
The part of
the number of
9Blocks(45)
○
04 “R04” N Block Write(All data) ×
05 “R05” Read Single Block UID(8)*1 Block#(1)
Security(1),
data(4)
○
06 “R06” Write Single Block UID(8)*1 Block#(1) Dummy(1),
data(4)
○
07 “R07” Lock Block UID(8)*1 Block#(1) Security(1),
data(4)
○
08 “R08” Read Multi Blocks
(Max=9Blocks)
UID(8)*1
S
Block#(1),
Block count(1)
The part of
the number of
9Block(45)
○
09 “R09” Write Multi Blocks ×
10 “R10” Select Tag UID(8) ○
11 “R11” Reset to Ready UID(8)*1 ○
12 “R12” Write AFI Flag(1),
UID(8)*1
DSFID(1),
AFI(1)
VICC(2),
IC(1)
○
13 “R13” Lock AFI UID(8)*1 ○
14 “R14” Write DSFID Flag(1),
UID(8)*1
DSFID(1),
AFI(1)
VICC(2),
IC(1)
○
15 “R15” Lock DSFID UID(8)*1 ○
16 “R16” Get System Information Flag(1),
UID(8)*1
DSFID(1),
AFI(1)
VICC(2),
IC(1)
○
17 “R17” Get Multi Block Security Status UID(8)*1
S
data(1),
data count(1)
The part of
the number of
32Block(32)
○
18 “R18” Write 2 Blocks
UID(8)*1 Block#(1),
2(1)
○
19 “R19” Lock 2 Blocks UID(8)*1 Block#1(1) ○
20 “R99” Error return Error flag(1) Error code(1) ○
notes:
S
=start、Block#=01〜64
(bytecount):The number in a parenthesis
It is related with an error return and is a reference of error handling.
“R03” is the same as “R08”
Thesegmentwhichislessthan the Block number of "R03", "R08", and "R17" is filled up with 0.
YY=A.D.(2000+YY)
"R18 [Write 2 Blocks]" and "R19 [Lock 2 Blocks]" are Tag-it. It is original command.
2D-53-00001000
TAMURA CORPORATION
-9
/
16 -
No command function parameter1 parameter2 parameter3
21
22
23 “R23”
24 “R24”
25 “R25”
26 “R26”
27 “R27”
28 “R28”
29 “R29”
30
31 “R31”* Inventory DSFID(1) UID(8) ○
32 “R32”* Stay Quiet UID(8) ○
33 “R33”* N Block Read(All data)
(Max=9Blocks)
UID(8)*1
S
Block#(1),
Block count(1)
The part of
the number of
9Blocks(45)
○
34
35 “R35”* Read Single Block
UID(8)*1 Block#(1) Security(1)
data(4)
○
36 “R36”* Write Single Block UID(8)*1 Block#(1) Dummy(1),
data(4)
○
37 “R37”* Lock Block
UID(8)*1 Block#(1) Security(1),
data(4)
○
38 “R38”* Read Multi Blocks
(Max=9Blocks)
UID(8)*1
S
Block#(1),
Block count(1)
The part of
the number of
9Blocks(45)
○
39
40 “R40”* Select Tag UID(8) ○
41 “R41”* Reset to Ready UID(8)*1 ○
42 “R42”* Write AFI Flag(1),
UID(8)*1
DSFID(1),
AFI(1)
VICC(2),
IC(1)
×
43 “R43”* Lock AFI UID(8)*1 ×
44 “R44”* Write DSFID Flag(1),
UID(8)*1
DSFID(1)
AFI(1)
VICC(2),
IC(1)
×
45 “R45”* Lock DSFID UID(8)*1 ×
46 “R46”* Get System Information Flag(1),
UID(8)*1
DSFID(1),
AFI(1)
VICC(2),
IC(1)
×
47 “R47”*
48 “R48”*
49 “R49”*
50
●* is command of a My-D card.
●My-D assumes 124Page (248Block) with the architecture of 4 bytes/Block now.
●Since the write-in result of My-D has returned transmission data as it is, read is required for it again.
2D-53-00001000
TAMURA CORPORATION
-10
/
16 -
6-3.Error handling
It consists of 2bytes of the error flag/error code.
The 1st byte :=0 →It is an error flag on a processing. The 2nd byte is an error code.
The 1st byte :≠0 →It is an error flag on a standards. The 2nd byte is an error code.
receive data
1 2 3 4 5 6 7 8 9
ENQ R 9 9 Error flag Error code CRC16(L) CRC16(H) EOT
flag=0 →code = 1 : The error under processing of Tag-it
→code = 2 : A processing of Tag-it times out.
flag≠0 →: JIS X 6323-3
Refer to (ISO/IEC 15693-3)
: Tag-it HF-I Transponder Inlay
Extended Commands and Options