Tarana G1 RN User manual

Tarana G1 RN Manual

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 1
Safety and Warnings......................................................................................................................2
General Warnings ......................................................................................................................2
FCC Information.........................................................................................................................2
Health and Safety Warning .....................................................................................................3
Warning Labels...........................................................................................................................3
Regulatory Information.................................................................................................................5
Deployment in the US – FCC Statement .............................................................................6
Deployment in Canada - Industry Canada Statements..................................................7
Deployment in the European Union – CE Mark.................................................................8
Preparation ....................................................................................................................................10
Tools Required ....................................................................................................................10
Tarana Hardware and Peripherals ................................................................................10
Customer Supplied Equipment......................................................................................10
Physical Installation.....................................................................................................................11
Preparing the RN......................................................................................................................11
Wall or Surface Mounting the Elevation Bracket ............................................................12
Pole Mounting the Elevation Bracket.................................................................................12
Installing the RN.......................................................................................................................13
Powering Up the RN................................................................................................................14
Warranty..........................................................................................................................................15
**NOTE** For the most up-to-date instructions, please download the latest version
of this document on our customer portal: www.taranawireless.com/private

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 2
Safety and Warnings
Tarana G1 equipment is designed for installation and use by trained professionals
and requires adherence to all relevant regulatory, safety, and telecom industry best
practice guidelines for outdoor radios.
General Warnings
Failure to observe these safety precautions may result in personal injury or damage
to equipment.
• Follow all warnings and instructions marked on this product.
• Use standard safety guidelines when mounting. Installation and
maintenance procedures must be followed and performed by trained
personnel only.
• Before unmounting the product, disconnect power input to reduce the risk
of hazards.
• Do not exceed 60 VDC of input to the device.
• Do not open the device. Opening the device voids the warranty.
• Do not stack anything on the radome.
• Dust covers must be installed on all connectors when not in use.
• Cable ends must be protected from weather if not connected to the device.
• When the SPF+ port is used, this is a Class 1 laser product. Invisible laser
radiation can be emitted from the aperture of the port when no fiber is
connected; therefore, avoid exposure to laser radiation and do not stare
into open apertures.
FCC Information
The FCC occupational controlled limit for maximum permissible exposure (MPE) is 5
mW/cm2. It is estimated that the maximum power density at the radome is 1.25
mW/cm2, which is below the FCC MPE limit. Since the power density for an
occupational controlled environment is less than the FCC limit, no additional
precautions are necessary. The occupational uncontrolled environment limit for
maximum permissible exposure (MPE) is 1 mW/cm2. To meet this MPE requirement,
the operator must be at a distance of 7.87 in or 20 cm away from the radome cover
of the system.
General Health and Safety Information
Topic
Explanation
Flammability
The equipment is designed and constructed to
minimize the risk of smoke and fumes during a fire.
Hazardous Materials
No hazardous materials are used in the
construction of this equipment.
Hazardous Voltage
The G1 system meets global product safety
requirements for safety extra-low voltage (SELV)
rated equipment.
Safety Signs
External warning signs or other indicators on the
equipment are not required.
Surface Temperatures
The external equipment surfaces become warm
during operation, due to heat dissipation. However,
the temperatures reached are not considered
hazardous.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 3
Health and Safety Warning
All personnel must comply with the relevant health and safety practices when
working on or around the G1 radio equipment.
The G1 system has been designed to meet relevant US and European health and
safety standards as outlined in IEC Publication 62368-1, 2nd edition.
Local safety regulations must be used if required. Safety instructions in this section
should be used in addition to the local safety regulations. In the case of conflict
between safety instructions stated herein and those indicated in local regulations,
mandatory local norms will prevail. Should local regulations not be mandatory,
then safety norms herein will prevail.
Warning Labels
WARRANTY VOID
DO NOT BREAK THE TAMPER SEALS ON HARDWARE. DOING SO WILL VOID THE
WARRANTY.
WARNING
Making adjustments and/or modifications to this equipment that are not in
accordance with the provisions of this User Guide, the Installation Guide or other
supplementary documentation may result in personal injury or damage to the
equipment, and may void the equipment warranty.
AVERTISSEMENT
Tout réglage ou modification faits à cet équipement hors du cadre édicté par ce
guide d’utilisation ou par toute autre documentation supplémentaire pourraient
causer des blessures ou endommager l’équipement et peut entraîner l’annulation
de sa garantie.
WARNUNG
Die an diesen Geräten gemachte Einstellungen und/oder Änderungen, welche nicht
gemäß dieser Bedienungsanleitung, oder gemäß anderen zusätzlichen Anleitungen,
ausgeführt werden, können Verletzungen oder Materialschäden zur Folge haben
und eventuell die Garantie ungültig machen.
ATENCIÓN
Llevar a cabo ajustamientos y/o modificaciones a este equipo, sin seguir las
instrucciones provistas por este manual u otro documento adicional, podría
resultar en lesiones a su persona o daños al equipo, y anular la garantía de este
último.
警告
进行调整和/或修改本设备是不符合本用户指南的规定,安装手册或其他补
充文件可能导致人身伤害或设备损坏,并可能会使设备保修。

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 4
General Hazards
Topic
Explanation
Chassis Earthing
The G1 chassis earth must be connected directly to the DC supply system earthing conductor, or to a bonding jumper from an earthing
terminal bar, or bus to which the DC supply system earthing is connected.
Protection from RF
Exposure
When installing, servicing or inspecting an antenna always comply with the following:
• Locate the antenna such that it does not infringe the RF Exposure Limit Distance, relating to the Compliance Boundary General Public.
• Stay aware of the potential risk of RF exposure and take appropriate precautions.
• Do not stand in front of or look into an antenna without first ensuring the associated transmitter or transmitters are switched off.
• At a multi-antenna site ask the site owner or operator for details of other radio services active at the site and for their
requirements/recommendations for protection against potentially harmful exposure to RF radiation.
• When it is not possible to switch transmitters off at a multi-antenna site and there is potential for exposure to harmful levels of RF
radiation, wear a protective suit.
Fiber Optic Cables
• Handle optical fibers with care. Keep them in a safe and secure location during installation.
• Do not attempt to bend them beyond their minimum bending radius.
• Protect/cover unconnected optical fiber connectors with dust caps.
Grounding Connections
Reliable grounding of the G1 chassis must be maintained.
Mains Power Supply
Routing
G1 DC power is not to be routed with any AC mains power lines. They are also to be kept away from any power lines which cross them.
Maximum Ambient
Temperature
The maximum ambient temperature for the G1 product is 55 degrees C. To ensure correct operation and to maximize long term component
reliability, ambient temperatures must not be exceeded. Operational specification compliance is not guaranteed for higher ambients. G1
should be mounted in such a way as to permit the vertical free flow of air through its cooling fins.
Mechanical Loading
When installing the G1 on a tower, ensure that the tower is securely anchored. Ensure that the additional loading of devices will not cause any
reduction in the mechanical stability of the tower.
Power Supply
Connection
G1 operates from a nominal -48 VDC power supply.
Power Supply
Disconnect
An appropriate power supply disconnect device should be provided as part of the installation.
Rack Mount
Temperature
Considerations
G1 is designed to operate in an outdoor environment with no significant obstructions in front of the radome. Do not install G1 in a closed or
multi-unit rack assembly, because such a closed rack would impede the propagation of the RF signals. The maximum ambient temperature
applies to the immediate operating environment of the G1 product.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 5
Regulatory Information
This device supports UNII-1 and UNII-3 in the FCC (USA); supports UNII-3 only in
ISED (Canada).
Compliance
Safety
• IEC 60529, 2013-08
• IP X7
• EN 62368-1:2014 (2nd Edition)
• IEC/EN 60950-22
Immunity
• EN61000-4-5 Level 4 AC Surge Immunity
• EN61000-4-4 Level 4 Electrical Fast Transient
Burst Immunity
• EN61000-4-3 Level 4 EMC Field Immunity
• EN61000-4-2 Level 2 ESD Immunity
Radio Approvals
• FCC Part 15 Subpart E §15.407
• RSS-192
• RSS-197
• RSS-199
• EN 302 326-2
• EN 302 502
EMI and susceptibility
• FCC part 15.207, 15.209
• ICES-003; RSS-Gen
• CAN ICES-3(B)/NMB-3(B)
• FCC 15B Class B

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 6
Deployment in the US – FCC Statement
This product must be professionally installed.
This device complies with FCC Part 15 rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
Modifications not expressly approved by Tarana Wireless Inc. could void the user's
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the FCC and ISED
limits for a digital device. These limits are designed to provide reasonable
protection against harmful interference.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This device complies with FCC RF exposure limits. This equipment should be
installed and operated with a minimum distance of 20 cm (7.9 in.) between the
radiator and user. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 7
Deployment in Canada - Industry Canada Statements
This product must be professionally installed.
This Class B Digital apparatus meets all the requirements of ICES-003.
To satisfy IC RF exposure requirements for RF transmit ting devices, the following
distances should be maintained between the antenna of this device and persons
during device operation: 20cm.
This device has been designed to ensure that radio frequency emissions are
maintained within the band of operation under all normal operating conditions
listed in this manual.
This device complies with Industry Canada RSS standard(s). Operation is subject to
the following two conditions:
This device may not cause interference, and
This device must accept any interference, including interference that may
cause undesired operation of the device.
Le produit final doit être installé par un professionnel
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
IC avertissements d'exposition RF Pour satisfaire les exigencies d’IC en ce qui a trait
aux expositions aux RF pour RF dispositifs de transmission, les distances
suivantes doit être maintenue entre l'antenne de ce dispositive et des personnes
pendant le fonctionnement du dispositif: 20cm.
Ce dispositif a été conçu pour veiller à ce que les émissions de radiofréquences
sont maintenus dans la bande de fonctionnement dans toutes les conditions
normales de fonctionnement figurant dans ce manuel.
Cet appareil est conforme la norme d'Industrie Canada RSS (s). Son
fonctionnement est soumis aux deux conditions suivantes:
Cet appareil ne peut pas causer d'interférences, et.
Cet appareil doit accepter toute interférence, y compris les interférences
qui peuvent causer un mauvais fonctionnement de l'appareil.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 8
Deployment in the European Union – CE Mark
This Product carries CE Mark:
Declaration of Conformity for radio equipment under the scope of
Directive 2014/53/EU (RED) statement
The Radio Equipment Directive 2014/53/EU (RED) establishes a regulatory
framework for placing radio equipment on the market. It ensures a Single Market for
radio equipment by setting essential requirements for safety and health,
electromagnetic compatibility, and the efficient use of the radio spectrum
Hereby, Tarana Wireless Inc. declares that the equipment documented in this
publication is in Compliance with the essential requirements and other relevant
provisions of Directive 2014/53/EU (RED).
The technical documentation as required by the Conformity Assessment procedure
is kept at Tarana Wireless Inc. location which is responsible for this product. For
more information please contact your local Tarana Wireless Inc. Customer Service
or Sales representative.
This declaration is only valid for G1 systems (hardware, software, and firmware) that
are provided for use within the EU. If this equipment is used in a manner not
specified by Tarana Wireless Inc. (including use of unsupported software or
firmware), it may result in the equipment no longer being compliant with the
regulatory requirements.
Tarana Products described above could face some restrictions to operate
in the following Countries:
AT
BE
BG
HR
CY
CZ
EE
FI
EL
FR
IT
LV
LT
LU
NL
PL
RO
SK
ES
SW
UK
DE
CH
LI
NO
IC
TR
This Product meets International guidelines for human exposure to RF
fields
Tarana Wireless systems are designed to be operated as to avoid contact with the
antennas by the end user. It is recommended to install the system in a location
where the antennas can remain at least a minimum distance as specified from the
user in accordance to the regulatory guidelines which are designed to reduce the
overall exposure of the user or operator. To meet radiation exposure requirements,
these devices should be installed at a minimum distance of 0.7083 from people or
animals.
E-Field Limit
(V/m)
Distance
(m)
61
0.7083
G1 product complies with RF Exposure Requirements: EN 62311
Eco-Environmental Statements
Electronic products and batteries bearing or referencing the symbols shown above
shall be collected and treated at the end of their useful life, in compliance with
applicable European Union and other local legislation. They shall not be disposed
of as part of unsorted municipal waste. Due to materials that may be contained in
the product and batteries, such as heavy metals, the environment and human
health may be negatively impacted as a result of inappropriate disposal.
WEEE, REACH and RoHS Compliance
Tarana Wireless products have been reviewed, analyzed and found to be following
the European Union (EU) directive for Waste Electrical and Electronic Equipment
(WEEE) WEEE Directive 2012/19/EU, with the EU directive for the Restriction of
Hazardous Substances (RoHS)
RoHS Directive 2011/65/EU and REACH Regulation
(EC) No 1907/2006.
WEEE Collection Programs in the U.S. and EU at end of product life (EOL), customers
are requested to contact Tarana Wireless to plan for WEEE collection/disposal of
their products. The Tarana collection center in the U.S. is at the following address:
Tarana Wireless Inc. 590 Alder Drive, Milpitas, CA 95035 Telephone: 408-351-4085

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 9
Nederlands
Dutch
De apparatuur is in overeenstemming met de essentiële eisen
en andere relevante bepalingen van Richtlijn 2014/53/EU
Malti
Malteese
Dan it-tagħmir huwa konformi mar-rekwiżiti essenzjali u
dispożizzjonijiet rilevanti oħra tad-Direttiva 2014/53/EU
Magyar
Hungarian
Ez a berendezés megfelel az alapvetőkövetelményeknek és más
vonatkozó rendelkezéseinek a 2014/53/EU
Norsk
Norwegian
Dette utstyret er i samsvar med grunnleggende krav og øvrige
relevante krav i direktiv 2014/53/EU
Polski
Polish
Ten sprzęt jest zgodny z zasadniczymi wymaganiami oraz
pozostałymi stosownymi postanowieniami Dyrektywy
2014/53/EU
Portugues
Portuguese
Este equipamento está em conformidade com os requisitos
essenciais e outras disposições relevantes da Directiva
2014/53/EU
Română
Romanian
Acest echipament este în conformitate cu cerințele esențiale și
alte prevederi relevante ale Directivei 2014/53/EU
Slovensko
Slovenian
Ta oprema je v skladu z bistvenimi zahtevami in drugimi
ustreznimi določbami Direktive 2014/53/EU
Slovenski
Slovak
Toto zariadenie je v súlade so základnými požiadavkami a
ďalšími príslušnými ustanoveniami smernice 2014/53/EU
Suomi
Finish
Tämä laite on olennaisten vaatimusten ja muiden määräysten
mukainen direktiivin 2014/53/EU
Swenska
Swedish
Denna utrustning är i överensstämmelse med väsentliga krav
och andra relevanta bestämmelser i direktivet 2014/53/EU
Hrvatski
Croatian
Ova oprema je u skladu s osnovnim zahtjevima i drugim
relevantnim odredbama Direktive 2014/53/EU
English
This equipment is in compliance with essential requirements
and other relevant provisions of Directive 2014/53/EU
Български
Bulgarian
Това оборудване евсъответствие сосновните изисквания и
съответващите разпоредби на Директива 2014/53/EU
Cesky
Czech
Toto zařízení je v souladu se základními požadavky a dalšími
příslušnými ustanoveními směrnice 2014/53/EU
Dansk
Danish
Dette udstyr er i overensstemmelse med væsentlige krav og
øvrige relevante bestemmelser i direktiv 2014/53/EU
Deuch
German
Dieses Gerät ist in Übereinstimmung mit den grundlegenden
Anforderungen und anderen Bestimmungen der Richtlinie
2014/53/EU
Esti
Estonian
See seade on vastavuses põhinõuetele ja muudele direktiivi
2014/53/EU
Español
Spanish
Este equipo cumple con los requisitos esenciales y otras
disposiciones pertinentes de la Directiva 2014/53/EU
Eλληνική
Greek
Αυτός οεξοπλισμός είναι σε συμμόρφωση με τις ουσιώδεις
απαιτήσεις και τις λοιπές σχετικές διατάξεις της οδηγίας
2014/53/EU
Français
French
Cet équipement est conforme aux exigences essentielles et aux
autres dispositions pertinentes de la Directive 2014/53/EU
Islenska
Islandic
Þessi búnaður er í samræmi viðgrunnkröfur og aðrar kröfur sem
gerðar eru í tilskipun 2014/53/EU
Italiano
Italian
Questa apparecchiatura è conforme ai requisiti essenziali e altre
disposizioni contenute nella Direttiva 2014/53/EU
Latviešu
Latvian
Šī iekārta atbilst būtiskajām prasībām un citiem ar to
saistītajiem noteikumiem Direktīvas 2014/53/EU
Lietuvių
Lithuanian
Ši įranga atitinka esminius reikalavimus ir kitas susijusias
nuostatas Direktyvos 2014/53/EU

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 10
Preparation
Tools Required
¨ 8mm socket driver
¨ Torque wrench
¨ #2 crosspoint screwdriver
¨ Crimping tool (14 AWG) for ground wire
Tarana Hardware and Peripherals
¨ RN radio unit
¨ RN mounting kit
o 1pcs - RN chassis bracket
o 1pcs - RN elevation Bracket
o 8pcs - M5 flanged-head screw with thread lock
o 2pcs - Wormdrive clamps
¨ Single hole ground lug
¨ Passive PoE injector with power cord
¨ 1 m Ethernet cable
Customer Supplied Equipment
¨ Ethernet cable - shielded CAT5e/CAT6
¨ RJ45 connectors
¨ Grounding wire (14 AWG)
¨ Earthing hardware
¨ Lightning and surge protection devices
RN Mounting Kit

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 11
Physical Installation
The RN mount is a saddle clamp that is adjustable in azimuth and tilt (20° uptilt – 5°
downtilt supported). In typical installation, the RN is installed on a pole mounted to
the side of a dwelling.
Preparing the RN
Step 1. Carefully place the RN face down on a surface that will not damage the
plastic radome.
Step 2. Place the chassis bracket onto the back of the RN and locate it onto the 4
threaded holes.
Step 3. Using an 8mm hex socket, install the four screws, and gradually torque
them in a crossing pattern to the specified torque value of 6 N-m (4.5 ft-lb)
Step 4. Partially install one screw on each of the elevation attachment tabs of the
chassis bracket in the locations closest to the top of the RN unit. These two
screws should be threaded into the tabs enough that 2 or 3 threads are
exposed coming out of the backside of each of the tabs.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 12
Wall or Surface Mounting the Elevation Bracket
Step 1. Using the elevation bracket as a template, mark the location of the 4 holes
at each corner of the bracket with the bracket oriented in the direction
depicted.
Step 2. Suitable fasteners 7mm or 8mm (not included) in diameter can be used
with the bracket without issue. Do not attempt to use fasteners smaller
than 6mm and never modify the elevation bracket by drilling for larger
than 8mm fasteners as it will damage the corrosion protection of the
finish.
Step 3. Install the elevation bracket with its elevation tabs facing outward and
oriented as shown.
Pole Mounting the Elevation Bracket
Step 1. Route the opened screw clamps through the Wall/Pole bracket so that the
serrated surfaces of the bracket will be facing the pole and the clamps will
go around the pole.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 13
Installing the RN
Step 1. Attach the ground system to the chassis first! There is a stainless screw
installed on the RN that is used for attaching the ground.
o Ground wire should be 14AWG (2.5mm2)
o A ring terminal suitable for the M5 screw should be crimped to the
ground wire.
o Torque screw to 6 N-m (4.5 ft - lb)
o Grounding wire shall not limit any adjustment needed or
alignment.
Additional local electrical codes and ordinances may apply to
grounding. Compliance in this area is the responsibility of the
installation company and not Tarana Wireless Inc.
Step 2. Install the body of the cord grip into the RN enclosure. Take care not to
cross thread the plastic threads of the cord grip body with the aluminum
threads of the RN enclosure.
Step 3. Properly terminate and test Ethernet cable run before proceeding. This
should include power verification on all pins of the Ethernet cable using a
POE tester.
Step 4. With POE power disconnected, slide the cord grip sealing nut and split
gland over and around the terminated RJ45 connector and cable.
Step 5. Carefully plug the RJ45 connector into the RN making sure there is an
audible click made by the connector properly seating into RJ45 receptacle
on the main PCB inside the RN enclosure. If the click is not heard a slight
pull on the Ethernet cable is sufficient to check if the cable has been
properly seated or not. DO NOT FORCIBLY pull on the Ethernet cable as it
could cause irreparable damage to the PCB.
Step 6. With the Ethernet cable connected, slide the split gland and sealing nut
down the Ethernet cable towards the RN and into place.
Step 7. While tightening this assembly together make sure that the Ethernet cable
is not being twisted in any way in the process.
Step 8. Install RN by lowering it onto the elevation bracket such that the partially
threaded-in screws are captured by the U-shaped features on the bracket.
Tighten the top screw on each side of the mount enough to prevent the RN
from coming loose while performing the next steps.
Step 9. Align the tilt adjustment slot so that the threaded holes in the elevation
attachment tabs of the chassis bracket tabs are accessible and install the
two lower screws (one on each side) and snug them. Final torque
sequence will follow after final alignment and pointing.

Tarana Wireless, Inc. Proprietary and ©2021. All rights reserved. vG1-RN-2021-01 G1 RN Manual — 14
Powering Up the RN
Step 1. Using the Tarana POE injector, apply power to Ethernet cable.
Step 2. Verify LED operation.
Step 3. Once the RF link is established, optimize alignment using RN local WebUI.
Step 4. Torque the four screws used on the elevation attachment tabs to 6 N-m
(4.5 ft-lb).
Step 5. Run final checks
a. Authentication
b. Internet connectivity
c. Internet speed test

Warranty
We warrant that commencing from the date of shipment to you (and in case of
resale to you by a Tarana partner, commencing not more than 90 days after our
original shipment), and continuing for a period of twelve (12) months, the hardware
will be free from defects in material and workmanship under normal use. This
limited warranty is not transferrable. Your sole and exclusive remedy and our entire
liability under this limited warranty will be, at our option, shipment of a
replacement or a refund of the purchase price, if you notify us of the defect within
the warranty period and return the hardware to us freight and insurance prepaid.
Parts used in replacement may be new or reconditioned. Our obligations are
conditioned upon the return of affected hardware in accordance with our then-
current standard Return Material Authorization (RMA) procedures. This limited
warranty does not cover (a) damage resulting from (i) use in other than the wireless
transport applications defined in our product documentation; (ii) use not in accord
with applicable spectrum regulations; (iii) handling, testing, installation, operation,
maintenance, service, repair, alteration, modification, or adjustment outside of
practices and conditions defined in our product documentation; (iv) other general
misuse, accident, liquid intrusion, or neglect; (v) unauthorized radio connection to
equipment not supplied by us; (vi) illegal or unauthorized alteration of software or
firmware; (vii) acts of nature (such as lightning) or performance failure of other
equipment (including electrical transients and over/under voltage); (b) scratches,
discoloration, or other cosmetic damage to surfaces that do not affect operation; (c)
normal and customary wear and tear; and (d) any product where serial number,
revision level, part number, date code, warranty data, tamper-proof seals, or quality
assurance decals have been removed or altered.
DISCLAIMER: Except as specified above, all express or implied conditions,
representations, and warranties including, without limitation, any implied
warranty or condition of merchantability, fitness for a particular purpose, non-
infringement, satisfactory quality, non-interference, accuracy of informational
content, or arising from a course of dealing, law, usage, or trade practice, are
hereby excluded to the extent allowed by applicable law and are expressly
disclaimed by us.
To the extent an implied warranty cannot be excluded, such
warranty is limited in duration to the express warranty period. This disclaimer and
exclusion will apply even if the express warranty set forth above fails of its essential
purpose.
Tarana products are not designed, intended, or certified for use in
communication systems for, or relating to (a) weapons or weapons systems,
(b) nuclear facilities, (c) air traffic control or other mass transportation systems,
(d) life support systems or other medical devices, (e) applications where
electrical sparks could trigger explosions or fires, or (f) any other systems,
devices or applications in which the failure of the product to operate as
intended may lead to death, bodily injury, or catastrophic property damage
(each an “Unauthorized Use”). Many of such Unauthorized Uses would require
specific industry certification which has not been sought or obtained for the
Tarana products.
LIABILITY.
We will not be liable for any special, incidental, indirect, or
consequential damages (including lost profits or property damage) arising out
of or relating to the sale of the goods to you or your possession, installation,
use, operation or repair of the goods, even if the goods are nonconforming,
defective, infringing, delayed, or not delivered, and even if we have been
advised of the possibility of such damages. You agree to indemnify and hold
us harmless from any claims, suits, demands and causes of action arising out
of or relating to your possession, installation, use, operation or repair of the
goods. Notwithstanding any other provisions of this document, in no event
will our total liability in connection with or relating to the goods exceed the
amount you have paid us for the goods.
Table of contents
Other Tarana Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Belimo
Belimo WGVL RV Series instruction manual

Dover
Dover Vitronics Soltec DeltaWave 6622cc installation guide

Festo
Festo CPV10-EX-VI Translation of the original instructions

Dive Gear Express
Dive Gear Express DGX Gears XTRA Service manual

SCHUNK
SCHUNK PGN-plus Series Assembly and operating manual

Strasbaugh
Strasbaugh 6DS-SP Operation manual