Taylor Wawa C708 User manual

Models C708 & C716
Heat Treatment
Soft Serve Freezer
Operating Instructions
059061--M
6/17/08

Complete this page for quick reference when service is required:
Taylor Distributor:
Address:
Phone:
Service:
Parts:
Date of Installation:
Information found on the data label:
Model Number:
Serial Number:
Electrical Specs: Voltage Cycle
Phase
Maximum Fuse Size: A
Minimum Wire Ampacity: A
EJanuary, 2005 Taylor
All rights reserved.
059061--M
The word Taylor and the Crown design
are registered trademarks in the United States
of America and certain other countries.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072

Models C708 & C716 Table of Contents
Table of Contents
Section 1 To the Installer 1............................................
Installer Safety 1........................................................
Site Preparation 1.......................................................
Air Cooled Units 2.......................................................
Water Connections (Water Cooled Units Only) 2............................
Electrical Connections 2.................................................
Beater Rotation 3.......................................................
Refrigerant 3...........................................................
Section 2 To the Operator 4...........................................
Compressor Warranty Disclaimer 4.......................................
Section 3 Safety 5....................................................
Section 4 Operator Parts Identification 7...............................
Model C708 7..........................................................
Model C716 8..........................................................
Model C708 Single Spout Door and Beater Assembly 9......................
Model C716 Door and Beater Assembly 10..................................
X57029-XX Pump A. - Mix Simplified (Model C708) 11........................
X57029-XX Pump A. - Mix Simplified (Model C716) 12........................
Accessories 13..........................................................
Brush Kit Assembly X44127 14............................................
Section 5 Important: To the Operator 15.................................
Symbol Definitions 16....................................................
Operating Screen Descriptions 17..........................................
Freezer Locks 20........................................................
Manager's Menu 22......................................................
Section 6 Operating Procedures 29.....................................
Freezing Cylinder Assembly 29............................................
Freezer Door Assembly 31................................................
Mix Pump Assembly 34...................................................
Sanitizing 37............................................................

Table of Contents Models C708 & C716
Table of Contents - Page 2
Priming 39..............................................................
Daily Closing Procedures 40..............................................
Daily Opening Procedures 41..............................................
Manual Brush Cleaning 42................................................
Draining Product From The Freezing Cylinder 42............................
Rinsing 43..............................................................
Hopper Cleaning 43......................................................
Disassembly 44..........................................................
Brush Cleaning 45.......................................................
Section 7 Important: Operator Checklist 46..............................
During Cleaning and Sanitizing 46.........................................
Troubleshooting Bacterial Count 46........................................
Regular Maintenance Checks 46...........................................
Winter Storage 47........................................................
Section 8 Troubleshooting Guide 48....................................
Section 9 Parts Replacement Schedule 52...............................
Section 10 Parts List 53.................................................
Wiring Diagrams 67......................................................
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
EJanuary, 2005 Taylor
All rights reserved.
059061-M
The word Taylor and the Crown design
are registered trademarks in the United States
of America and certain other countries.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072

1
Models C708 & C716 To the Installer
081208
Section 1 To the Installer
The following are general installation instructions.
For complete installation details, please see the
check out card.
Installer Safety
In all areas of the world, equipment should
be installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and
service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer
must be disconnected prior to performing any
repairs. Failure to follow this instruction may result in
personal injury or death from electrical shock or
hazardous moving parts as well as poor
performance or damage to the equipment.
Note:Allrepairsmustbeperformedbyan
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Site Preparation
Review the area the unit is to be installed in before
uncrating the unit making sure that all possible
hazards the user or equipment may come into have
been addressed.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70_-75_F(21_-24_C). The freezer
has successfully performed in high ambient
temperatures of 104_(40_C) at reduced capacities.
This unit must NOT beinstalledinanarea
where a water jet or hose can be used. NEVER use
a water jet or hose to rinse or clean the unit. Failure
to follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should
be taken in moving this equipment for any reason.
Two or more persons are required to safely move
this unit. Failure to comply may result in personal
injury or equipment damage.
Uncrate the unit and inspect it for damage. Report
any damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

2 Models C708 & C716To the Installer
080912
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Model C708: Requires a minimum of 6” (152 mm) of
clearance on both sides and 0” in the rear of the
unit.
Model C716: Requires a minimum of 3” (76 mm) of
clearance on all sides. Install the deflector provided
to prevent recirculation of warm air.
This will allow for adequate air flow across the
condensers. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the
compressors.
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided
with a hand shut-off valve. On the underside of the
base pan or on the right side, two 3/8” I.P.S. water
connections for inlet and outlet are provided for easy
hook-up. 1/2” inside diameter water lines should be
connected to the machine. (Flexible lines are
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install
a water strainer to prevent foreign substances from
clogging the automatic water valve. There will be
only one water “in” and one water “out” connection.
DO NOT install a hand shut-off valve on the water
“out” line! Water should always flow in this order:
first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an opentrapdrain.
A back flow prevention device is
required on the incoming water connection side.
Please refer to the applicable National, State, and
local codes for determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety. In all
other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each freezer requires one power supply for each
data label. Check the data label on the freezer for
fuse, circuit ampacity and electrical specifications.
Refer to the wiring diagram provided inside of the
electrical box, for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipments frame.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to

3
Models C708 & C716 To the Installer
080912
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures must be performed
by an authorized Taylor service technician.
To correct rotation on a three-phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single-phase unit, change
the leads inside the beater motor. (Follow diagram
printed on motor.)
Electrical connections are made directly to the
terminal block provided in the main control box,
located: C708 - behind the rear panel.
C716 - behind the lower front panel.
Refrigerant
In consideration of our environment, Taylor
proudly uses only earth friendly HFC refrigerants.
The HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
apply ice packs and contact a physician
immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely
moisture absorbent. When opening a refrigeration
system, the maximum time the system is open must
not exceed 15 minutes. Cap all open tubing to
prevent humid air or water from being absorbed by
the oil.

4 Models C708 & C716To the Operator
080714
Section 2 To the Operator
Your freezers have been carefully engineered and
manufactured to give you dependable operation.
These units, when properly operated and cared for,
will produce a consistent quality product. Like all
mechanical products, they will require cleaning and
maintenance. A minimum amount of care and
attention is necessary if the operating procedures
outlined in this manual are followed closely.
This Operator's Manual should be read before
operating or performing any maintenance on your
equipment.
Your Taylor freezer will NOT eventually compensate
for and correct any errors during the set-up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that personnel responsible for the
equipment's operation, both assembly and
disassembly, go through these procedures together
in order to be properly trained and to make sure that
no confusion exists.
In the event you should require technical assistance,
please contact your local authorized Taylor
Distributor.
Note: Warranty is valid only if the parts are
authorized Taylor parts, purchased from an
authorized Taylor Distributor, and the required
service work is provided by an authorized Taylor
service technician. Taylor reserves the right to deny
warranty claims on equipment or parts if
non-approved parts or refrigerant were installed in
the machine, system modifications were performed
beyond factory recommendations, or it is determined
that the failure was caused by neglect or abuse.
Note: Constant research results in steady
improvements; therefore, information in this
manual is subject to change without notice.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other
similar legislation in effect after August 13, 2005.
Therefore, it must be collected separately after its
use is completed, and cannot be disposed as
unsorted municipal waste.
The user is responsible for returning the product to
the appropriate collection facility, as specified by
your local code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or
local distributor.
Compressor Warranty Disclaimer
The refrigeration compressors on this machine are
warranted for the term indicated on the warranty
card accompanying this machine. However, due to
the Montreal Protocol and the U.S. Clean Air Act
Amendments of 1990, many new refrigerants are
being tested and developed, thus seeking their way
into the service industry. Some of these new
refrigerants are being advertised as drop-in
replacements for numerous applications. It should
be noted that, in the event of ordinary service to this
machine's refrigeration system, only the refrigerant
specified on the affixed data label should be
used. The unauthorized use of alternate refrigerants
will void your compressor warranty. It will be the
owner's responsibility to make this fact known to any
technician he employs.
It should also be noted that Taylor does not warrant
the refrigerant used in its equipment. For example, if
the refrigerant is lost during the course of ordinary
service to this machine, Taylor has no obligation to
either supply or provide its replacement either at
billable or unbillable terms. Taylor does have the
obligation to recommend a suitable replacement if
the original refrigerant is banned, obsoleted, or no
longer available during the five year warranty of the
compressor.
Taylor will continue to monitor the industry and test
new alternates as they are being developed. Should
a new alternate prove, through our testing, that it
would be accepted as a drop-in replacement, then
the above disclaimer would become null and void.
To find out the current status of an alternate
refrigerant as it relates to your compressor warranty,
call the local Taylor Distributor or the Taylor Factory.
Be prepared to provide the Model/Serial Number of
the unit in question.

5
Models C708 & C716 Safety
080912
Section 3 Safety
We at Taylor Company are concerned about the
safety of the operator when he or she comes in
contact with the freezer and its parts. Taylor has
gone to extreme efforts to design and manufacture
built-in safety features to protect both you and the
service technician. As an example, warning labels
have been attached to the freezer to further point
out safety precautions to the operator.
IMPORTANT - Failure to adhere to the
following safety precautions may result in
severe personal injury or death. Failure to
comply with these warnings may damage the
machine and its components. Component
damage will result in part replacement expense
and service repair expense.
DO NOT operate the freezer without
reading this Operator Manual. Failure to follow this
instruction may result in equipment damage, poor
freezer performance, health hazards, or personal
injury.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipments frame.
DO NOT use a water jet to clean or rinse
the freezer. Failure to follow these instructions may
result in serious electrical shock.
SDO NOT operate the freezer unless it is
properly grounded.
SDO NOT operate the freezer with larger
fuses than specified on the freezer data
label.
SDO NOT attempt any repairs unless the
main power supply to the freezer has been
disconnected. Contact your local authorized
Taylor Distributor for service.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.

6 Models C708 & C716Safety
080826
SDO NOT allow untrained personnel to
operate this machine.
SDO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
SDO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
SDO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
SUSE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
SCAUTION-SHARP EDGES: Two people are
required to handle the cup/cone dispenser.
Protective gloves must be worn and the
mounting holes must NOT be used to lift or
hold the dispenser. Failure to follow this
instruction can result in personal injury to
fingers or equipment damage.
This freezer must be placed on a level
surface. Failure to comply may result in personal
injury or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this manual for the proper
procedure to clean this unit.
DO NOT obstruct air intake and discharge openings:
C708: A minimum of 6” (152 mm) air space is
required on both sides and 0” on the rear.
C716: A minimum of 3” (76 mm) air space is
required on all sides. Install the deflector provided to
prevent recirculation of warm air.
Failure to follow these instructions may cause poor
freezer performance and damage to the machines.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70_-75_F(21_-24_C). The
freezer has successfully performed in high ambient
temperatures of 104_(40_C) at reduced capacities.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.

7
Models C708 & C716 Operator Parts Identification
Section 4 Operator Parts Identification
Model C708
Figure 1
ITEM DESCRIPTION PART NO.
1PANEL-SIDE-LEFT 056963
2PAN-DRIP 11-5/8 LONG 027503
3PIN-RETAINING-HOPPER CVR 043934
4COVER-HOPPER *BLACK 053809-1
5BLADE A.-AGITATOR X56591
6PUMP A.-MIX SIMPLIFIED S.S. X57029-14
7PANEL-REAR 056077
8PAN A.-DRIP 5 1/2” LONG X56074
ITEM DESCRIPTION PART NO.
9SCREW-1/4-20X3/8 RHM-STNLS 011694
10 PANEL A-SIDE-RIGHT X57871
11 PANEL A.-FRONT-UPPER X59423
12 PANEL A.-FRONT-LOWER X58955
13 STUD-NOSE CONE 055987
14 SHELF-TRAY-DRIP 056076
15 TRAY-DRIP 056858
16 SHIELD-SPLASH 049203

8 Models C708 & C716Operator Parts Identification
061228
Model C716
Figure 2
ITEM DESCRIPTION PART NO.
1COVER-HOPPER 053809-1
2BLADE A.-AGITATOR X56591
3PANEL-REAR 059916
4PAN-DRIP 7.875 059737
5PUMP A.-MIX SIMPLIFIED X57029-14
6PANEL-SIDE-RIGHT 059907
7PANEL A.-FRONT X63879
8PANEL A.-FRONT X59836
9PAN-DRIP 12.5 059736
10 FILTER-AIR-POLY-FLO 052779-11
ITEM DESCRIPTION PART NO.
11 PANEL A.-FILTER-LOUVERED X59928
12 SCREW-1/4-20 X 3/8 RHM-SS 011694
13 DEFLECTOR 059929
14 TRAY-DRIP-19-5/8 L X 4-7/8 033812
15 SHIELD-SPLASH-WIRE-19-3/4 L 033813
16 PAN-DRIP 19-1/2 LONG 035034
17 STUD-NOSE CONE 055987
18 PIN-RETAINING-HOPPER CVR 043934
19 PANEL-SIDE-LEFT 059906

9
Models C708 & C716 Operator Parts Identification
Model C708 Single Spout Door and Beater Assembly
Figure 3
ITEM DESCRIPTION PART NO.
1HANDLE A.-DRAW-WELDED X56246
2NUT-STUD-BLACK 2.563“ 058764
3DOOR A.-W/BAFFLE X57332-SER
4VALVE A.-DRAW X55820
5O-RING-DRAW VALVE-S.S. 014402
6PIN-HANDLE-SS 055819
7GASKET-DOOR HT 4”-DBL 048926
8BEARING-FRONT-SHOE 050348
9SHOE-FRONT HELIX *REAR* 050346
ITEM DESCRIPTION PART NO.
10 SHOE-FRONT HELIX *FRONT* 050347
11 BEATER A.-3.4QT-1 PIN X46231
12 BLADE-SCRAPER-PLASTIC 046235
13 CLIP-SCRAPER BLADE 7.00 046236
14 SHAFT-BEATER 056078
15 SEAL-DRIVE SHAFT 032560
16 NUT-STUD-BLACK 3.250” 058765
17 O-RING-1/4 OD X .070W 50 015872
18 SCREW-ADJUSTMT-5/16-24 056332

10 Models C708 & C716Operator Parts Identification
080805
Model C716 Door and Beater Assembly
Figure 4
ITEM DESCRIPTION PART NO.
1HANDLE A.-DRAW-WELDED X56421-1
2NUT-STUD-BLACK 3.250 LONG 058765
3NUT-STUD*BLACK 2.563 LONG 058764
4DOOR A.-3SPT*HT*LG BAF X59923-SER
5PIN-HANDLE-TWIN 059894
6GASKET-DOOR HT 4”-DOUBLE 048926-1
7O-RING--7/8 OD X .103W 014402
8VALVE A.-DRAW X59888
9VALVE A.-DRAW*CENTER X59890
10 SHOE-FRONT HELIX *FRONT* 050347
ITEM DESCRIPTION PART NO.
11 BEARING-FRONT-SHOE 050348
12 SHOE-FRONT HELIX *REAR* 050346
13 BLADE-SCRAPER-PLAS 8-1/8L 046235
14 CLIP-SCRAPER BLADE 7.00” 046236
15 BEATER A.-3.4QT-1 PIN X46231
16 SHAFT-BEATER 032564
17 SEAL-DRIVE SHAFT 032560
18 O-RING-1/4 OD X .070W 50 015872
19 SCREW-ADJUSTMENT-5/16-24 056332
20 SEAL-DRAW VALVE H-RING 034698

11
Models C708 & C716 Operator Parts Identification
X57029-XX Pump A. - Mix Simplified (Model C708)
Figure 5
ITEM DESCRIPTION PART NO.
1-7 PUMP ASSEMBLY - MIX
SIMPLIFIED SOFT SERVE X57029-14*
1CYLINDER-PUMP-HOPPER-
SOFT SERVE 057943
2PIN A.-RETAINING X55450
3PISTON 053526
4O-RING 2-1/8” OD - RED 020051
5CAP-VALVE 056874-14*
6GASKET - SIMPLIFIED PUMP
VALVE 053527
7ADAPTOR - MIX INLET 054825
8O-RING - 11/16 OD - RED 016132
ITEM DESCRIPTION PART NO.
9PIN - COTTER 044731
10 SHAFT A.-DRIVE-MIX PUMP-
HOPPER X41947
10a CRANK-DRIVE 039235
10b SHAFT-DRIVE 041948
11 O-RING - DRIVE SHAFT 048632
12 O-RING 1-3/4 008904
13 CLIP-MIX PUMP RETAINER 044641
14 TUBE A.-FEED HOPPER
SOFT SERVE X56521
15 RING-CHECK .120 OD 056524
*NOTE: THE STANDARD PUMP X57029-XX IS A -14.
OVERRUN CAN BE CHANGED HIGHER OR LOWER
BY SUBSTITUTING THE CAP (056874-XX) WITH
CAPS AVAILABLE -1 THROUGH -20. THE HIGHER
THE DASH (-) NUMBER, THE HIGHER THE
OVERRUN.

12 Models C708 & C716Operator Parts Identification
X57029-XX Pump A. - Mix Simplified (Model C716)
Figure 6
ITEM DESCRIPTION PART NO.
1-7 PUMP ASSEMBLY - MIX
SIMPLIFIED SOFT SERVE X57029-14*
1CYLINDER-PUMP-HOPPER-
SOFT SERVE 057943
2PIN A.-RETAINING X55450
3PISTON 053526
4O-RING 2-1/8” OD - RED 020051
5CAP-VALVE 056874-14*
6GASKET - SIMPLIFIED PUMP
VALVE 053527
7ADAPTOR - MIX INLET 054825
8O-RING - 11/16 OD - RED 016132
ITEM DESCRIPTION PART NO.
9PIN - COTTER 044731
10 SHAFT A.-DRIVE-MIX PUMP-
HOPPER X41947
10a CRANK-DRIVE 039235
10b SHAFT-DRIVE 041948
11 O-RING - DRIVE SHAFT 048632
12 O-RING 1-3/4 008904
13 CLIP-MIX PUMP RETAINER 044641
14 RING-CHECK .120 OD 056524
15 TUBE A.-FEED-LEFT X59808
16 TUBE A.-FEED-RIGHT X59809
*NOTE: THE STANDARD PUMP X57029-XX IS -14.
OVERRUN CAN BE CHANGED HIGHER OR LOWER
BY SUBSTITUTING THE CAP (056874-XX) WITH
CAPS AVAILABLE -1 THROUGH -20. THE HIGHER
THE DASH (-) NUMBER, THE HIGHER THE
OVERRUN.

13
Models C708 & C716 Operator Parts Identification
060629
Accessories
Figure 7
ITEM DESCRIPTION PART NO.
1SANITIZER-KAY 5 CASE 125 041082
2TOOL-O-RING REMOVAL 048260-WHT
3TOOL-SHAFT-DRIVE-PUMP-
HOPPER 057167
4LUBRICANT-TAYLOR HI-PERF 048232
ITEM DESCRIPTION PART NO.
5PAIL-MIX 10 QT. 013163
*KIT A.-TUNE-UP (C708) X56085
*KIT A.-TUNE-UP (C716) X49463-82
*KIT A.-PARTS TRAY (C708) X57797
*KIT A.-PARTS TRAY (C716) X58449
*NOT SHOWN

14 Models C708 & C716Operator Parts Identification
Brush Kit Assembly X44127
Figure 8
ITEM DESCRIPTION PART NO.
1BLACK BRISTLE BRUSH 013071
2DOUBLE END BRUSH 013072
3WHITE BRISTLE BRUSH 1” x 2” 013073
4WHITE BRISTLE BRUSH
1-1/2” x 3” 014753
ITEM DESCRIPTION PART NO.
5WHITE BRISTLE BRUSH 1/2 x 3 033059
6BRUSH SET (3) 050103
7YELLOW BRISTLE BRUSH 039719
8WHITE BRISTLE BRUSH 3” x 7” 023316
9PUMP SPOUT BRUSH 054068

15
Models C708 & C716 Important: To the Operator
Section 5 Important: To the Operator
C708 C716
Figure 9
ITEM DESCRIPTION
1POWER SWITCH
2LIQUID CRYSTAL DISPLAY
3KEYPADS
4MIX OUT INDICATOR
5STANDBY INDICATOR
6MIX LOW INDICATOR
7SELECT KEY
8SERVICE MENU KEY
9BRUSH CLEAN COUNTER
10 ARROW KEY(S)

16 Models C708 & C716Important: To the Operator
050628
Symbol Definitions
To better communicate in the International arena,
symbols have replaced words on many of our
operator switches, function, and fault indicators.
Your Taylor equipment is designed with these
International symbols.
The following chart identifies the symbol definitions.
= SELECT
= UP ARROW
= DOWN ARROW
=AUTO
= HEAT CYCLE
= WASH
=MIXLOW
= MIX OUT
= MENU DISPLAY
=MIXPUMP
= STANDBY
Power Switch
When placed in the ON position, the power switch
allows control panel operation.
Fluorescent Display
The fluorescent display is located on the front
control panel. During normal operation the display is
blank. The display is used to show menu options
and notifies the operator if a fault is detected. On
International models, the display will indicate the
temperature of the mix in the hopper.
Indicator Lights
MIX LOW - When the MIX LOW symbol is
illuminated, the mix hopper has a low supply of mix
and should be refilled as soon as possible.
MIX OUT - When the MIX OUT symbol is
illuminated, the mix hopper has been almost
completely exhausted and has an insufficient supply
of mix to operate the freezer. At this time, the AUTO
mode is locked out and the freezer will be placed in
the STANDBY mode. To initiate the refrigeration
system, add mix to the mix hopper and touch the
AUTO symbol . The freezer will automatically
begin operation.
HEAT MODE - When the HEAT MODE symbol
is illuminated, the freezer is in the process of a heat
cycle.
BRUSH CLEAN COUNTER - When the BRUSH
CLEAN COUNTER display has counted down to “1”,
the machine must be disassembled and brush
cleaned within 24 hours.
Reset Mechanism
The reset button is located in the service panel on
the left side of the C708. The reset buttons are
located in the back panel of the C716. A reset button
protects the beater motor from an overload
condition. Should an overload occur, the reset
mechanism will trip. To properly reset the freezer
place the power switch in the OFF position. Press
the reset button firmly. Turn the power switch to the
ON position. Touch the WASH symbol and
observe the freezer's performance.
WARNING: Do not use metal objects to
press the reset button. Failure to comply may
result in severe personal injury or death.
Other manuals for Wawa C708
4
This manual suits for next models
1
Table of contents
Other Taylor Ice Cream Maker manuals

Taylor
Taylor C125 Instructions for use

Taylor
Taylor Freezemaster 336 User manual

Taylor
Taylor 161 SOFT User manual

Taylor
Taylor Freezemaster 336 User manual

Taylor
Taylor Horizon 8756 User manual

Taylor
Taylor Freezemaster 300 Series User manual

Taylor
Taylor C712 User manual

Taylor
Taylor Taylormate 152 User manual

Taylor
Taylor Soft Serve Little Softy User manual

Taylor
Taylor Horizon 8752 User manual