3. Explanation of Functions and Precautions
3-1. Input Voltage Range
Input voltage range is single phase 85 ~ 264VAC (47 ~ 63Hz) or 120 ~ 373VDC.
Input voltage which is out of specification, may damage the unit. For cases where conformance to vari-
ous safety specifications (UL, CSA, EN) are required, input voltage range shall be 100~240VAC
(50/60Hz).
Note: LS200 series is able to withstand Input Surge of 300VAC for 5 seconds.
3-2. Output Voltage Range
V.ADJ trimmer is for output voltage adjustment within the range of specifications. Turning the trimmer
clockwise will increase the output voltage. Kindly note that Over Voltage Protection (OVP) function
may trigger if the output voltage is increased excessively. Please ensure that the output power is below
the rated output power, and output current is below the maximum output current (3.3V ~ 15V and 48V)
or below the peak output current (24V ~ 36V) when output voltage is raised.
3-3. Inrush Current
Power Thermistor is built in to protect the circuit from high Inrush Current. Please select suitable input
switch and fuse rating in case of re-input the power at high temperature.
3-4. Over Voltage Protection (OVP)
The OVP function will shutdown the output. The input shall be removed for a few minutes, and then re-
input for recovery of the output. OVP setting is fixed and cannot be adjusted externally.
3-5. Over Current Protection (OCP)
OCP function activates when the output current exceeds the specified OCP limit. The output will auto-
matically recover when the overload condition is removed. Do not operate overload or dead short con-
ditions for more than 30 seconds, which could result in damage. There is no possibility of fire or burn-
ing.
3-6. Over Temperature Protection (OTP)
Over Temperature Protection function (manual reset type) is available. When ambient or internal tem-
perature rises abnormally, OTP function will shut down the output. To recover the unit, first shut down
the AC input and let the unit cool down before turning ON the AC input.
3-7. Remote Sensing (+S, -S terminal)
Remote sensing function is provided to compensate for voltage drop across the wiring from the power
supply output terminals to the load input terminals. Connect “+S” terminal to “+Vm” terminal of the
load and “-S” terminal to the “-Vm” terminal of the load with sensing wires. The total line voltage
drop (+Vm side line and –Vm side line) shall be less than 0.3V. In the case that sensing wires are too
long, it is necessary to put an electrolytic capacitor across the load terminals. Example of external ca-
pacitor is listed in the table below :
Minimum external capacitance at the load input terminal
MODEL 3.3V 5V 7.5V 12V 15V 24V 36V 48V
LS200 2,200uF 1,000u 470uF